Document
... Existing system: Full bridge is an integral part of many DC/DC converters for applications like renewable energy interfaces, LED integration and communication power supplies. In order to increase the conversion efficiency, the soft switching technique is introduced to effectively reduce the switch ...
... Existing system: Full bridge is an integral part of many DC/DC converters for applications like renewable energy interfaces, LED integration and communication power supplies. In order to increase the conversion efficiency, the soft switching technique is introduced to effectively reduce the switch ...
Document
... As shown in Fig. 6 the control scheme consists of two major b locks i.e. the current control and the DC control. The current control is the inner control loop, which controls the current Ish,1. The reference of the q co mponent of the current is fro m the central control and the reference signal of ...
... As shown in Fig. 6 the control scheme consists of two major b locks i.e. the current control and the DC control. The current control is the inner control loop, which controls the current Ish,1. The reference of the q co mponent of the current is fro m the central control and the reference signal of ...
Test Procedure for the NCS8353MNGEVB Evaluation Board
... 1. Before powering up the board verify voltage and input polarity, connect the input source while it is off. 2. Place a jumper on the 3.3V_EN header pins. 3. Connect an input source to the R_IN and L_IN RCA input connectors. a. Most waveform generators are single-ended sources so a jumper needs to b ...
... 1. Before powering up the board verify voltage and input polarity, connect the input source while it is off. 2. Place a jumper on the 3.3V_EN header pins. 3. Connect an input source to the R_IN and L_IN RCA input connectors. a. Most waveform generators are single-ended sources so a jumper needs to b ...
to this file: /tps_tx1000
... Per MIL-STD-810D, Method 516.3, Procedure II, in each axis, including NTSA drop test Per MIL-STD-810D, Method 514.3, Procedure II, in each axis, including NTSA drop test The TX1000 is provided with an internal cooling fan. ...
... Per MIL-STD-810D, Method 516.3, Procedure II, in each axis, including NTSA drop test Per MIL-STD-810D, Method 514.3, Procedure II, in each axis, including NTSA drop test The TX1000 is provided with an internal cooling fan. ...
lecture - APM Overview - 201404
... • State and Control Variables (AA241X_aux.h) – Roll, pitch, yaw angles and rates – Inertial velocity and accelerations ...
... • State and Control Variables (AA241X_aux.h) – Roll, pitch, yaw angles and rates – Inertial velocity and accelerations ...
MIL-STD-883H METHOD 3007.1 LOW LEVEL OUTPUT VOLTAGE 1
... 1. PURPOSE. This method establishes the means for assuring circuit performance to the limits specified in the applicable acquisition document with regard to LOW level output drive which is specified as a maximum value (V OL max) or a minimum value (V OL min). This method applies to digital microelec ...
... 1. PURPOSE. This method establishes the means for assuring circuit performance to the limits specified in the applicable acquisition document with regard to LOW level output drive which is specified as a maximum value (V OL max) or a minimum value (V OL min). This method applies to digital microelec ...
AN OVERVIEW OF A CONTINUOUS MONITORING AND CONTROL
... The speed and accuracy of the operation can be greatly enhanced using this type of control system. But the biggest benefit in using a PLC is the ability to change and replicate the operation or process while collecting and communicating vital information. Since there were problems related to large e ...
... The speed and accuracy of the operation can be greatly enhanced using this type of control system. But the biggest benefit in using a PLC is the ability to change and replicate the operation or process while collecting and communicating vital information. Since there were problems related to large e ...
- Lotus Live Projects
... electronics to digitize the power so that a sequence of voltage pulses can be generated by the on and off of the power switches. The pulse width modulation inverter has been the main choice in power electronics for a decade, because of its simple circuitry and rugged control scheme. Spwm technique i ...
... electronics to digitize the power so that a sequence of voltage pulses can be generated by the on and off of the power switches. The pulse width modulation inverter has been the main choice in power electronics for a decade, because of its simple circuitry and rugged control scheme. Spwm technique i ...
IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE)
... order to overcome this, the hybrid controller is designed as a combination of both PI controller and Fuzzy Logic Controller, there by gaining the joint advantages of both types. The designed model has been tested in a 2 machine 3 bus test system using MATLAB software. The simulation results show tha ...
... order to overcome this, the hybrid controller is designed as a combination of both PI controller and Fuzzy Logic Controller, there by gaining the joint advantages of both types. The designed model has been tested in a 2 machine 3 bus test system using MATLAB software. The simulation results show tha ...
Sailwind Apartments – Winter Haven Florida is looking for a HVAC
... Sailwind Apartments – Winter Haven Florida is looking for a HVAC certified maintenance technician Job Description: The Maintenance Technician is responsible for safely maintaining the physical condition and appearance of the community. He or she should be able to diagnose problems and make minor rep ...
... Sailwind Apartments – Winter Haven Florida is looking for a HVAC certified maintenance technician Job Description: The Maintenance Technician is responsible for safely maintaining the physical condition and appearance of the community. He or she should be able to diagnose problems and make minor rep ...
Basic Control Package To Run Two Wells
... adjustable timed cycles to get the most from each well. Runs one well at a time. • Panel includes circuit breakers • Push to test pump relays • Each well pump has HOA switch • Control panel available for ½ - 3 HP 120V or 240V submersible, jet or centrifugal pressure pumps. (specify voltage ordering) ...
... adjustable timed cycles to get the most from each well. Runs one well at a time. • Panel includes circuit breakers • Push to test pump relays • Each well pump has HOA switch • Control panel available for ½ - 3 HP 120V or 240V submersible, jet or centrifugal pressure pumps. (specify voltage ordering) ...
Editorial - Korba - World Automation Congress
... automation of power systems without any restrictions to using soft computing techniques. Electric power systems belong to the most important and largest achievements ever built by humans. Today, many power systems, originally designed to cover needs in power supply rather locally, often exceed the s ...
... automation of power systems without any restrictions to using soft computing techniques. Electric power systems belong to the most important and largest achievements ever built by humans. Today, many power systems, originally designed to cover needs in power supply rather locally, often exceed the s ...
Control system

A control system is a device, or set of devices, that manages, commands, directs or regulates the behavior of other devices or systems. Industrial control systems are used in industrial production for controlling equipment or machines.There are two common classes of control systems, open loop control systems and closed loop control systems. In open loop control systems output is generated based on inputs. In closed loop control systems current output is taken into consideration and corrections are made based on feedback. A closed loop system is also called a feedback control system. The human body is a classic example of feedback systems.