• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Wide Supply Range, Rail-to-Rail Output Instrumentation Amplifier AD8226 Preliminary Technical Data
Wide Supply Range, Rail-to-Rail Output Instrumentation Amplifier AD8226 Preliminary Technical Data

... 650 mV. This combined signal can be limited by the voltage supplies even when the individual input and output signals are not. Figure XX through Figure XX show the allowable common-mode input voltage ranges for various output voltages and supply voltages. The following formulas can also be used to u ...
The PV Combiner Multiple Strings May Need Combiner
The PV Combiner Multiple Strings May Need Combiner

Current control loop design and analysis based on resonant
Current control loop design and analysis based on resonant

Aalborg Universitet
Aalborg Universitet

Aalborg Universitet Guerrero, Josep M.
Aalborg Universitet Guerrero, Josep M.

... power network, similar to the traditional AC power flow, they use slack DC bus in the model with the capability of balancing the active power in the network with constant DC voltage [9],[10]. It is not, however, the case in reality. In order to fully analyze the steady state feature of the DC microg ...


MixPre-D - User Guide and Technical Information
MixPre-D - User Guide and Technical Information

ADM3101E 数据手册DataSheet 下载
ADM3101E 数据手册DataSheet 下载

... Positive and Negative Connections for Charge Pump Capacitor. External Capacitor C1 is connected between these pins; a 0.1 μF capacitor is recommended, but larger capacitors up to 10 μF can be used. Receiver Output. This pin outputs CMOS output logic levels. Transmitter (Driver) Input. This input acc ...
MIL-STD-461 EMI INPUT FILTER FGDS-10A
MIL-STD-461 EMI INPUT FILTER FGDS-10A

... As it can be seen from the preceding equation, the worst case for system’s stability is at Vinmin, so this is the condition which should be considered for the filter design. As the filter is made of low ESR inductors and ceramic capacitors, it has an important quality factor Q which causes a sharp i ...
Physiological Monitor for the Prevention of Heat-Related Injuries
Physiological Monitor for the Prevention of Heat-Related Injuries

... body is too low and this can result to a range of problems from headaches and nausea to serious health problems such as seizures and respiratory arrest [7, 14]. For the monitoring of the core body temperature, the principal of zeroheat flow has been determined as the best method [11]. After the phys ...
A comparative assessment of hysteresis and dead beat controllers
A comparative assessment of hysteresis and dead beat controllers

... beat control have the most effective performance in controlling APFS. Hysteresis control directly compares the measured and reference currents and selects a switching state accordingly. It has the fastest speed of response, not being delayed by any A/D conversion process or calculation time. Among d ...
яю- w w w . D a t a S h e e t 4 U . c o m
яю- w w w . D a t a S h e e t 4 U . c o m

... A resistor connected between RI and GND sets the constant current source to charge/discharge the internal cap and thus the PWM oscillator frequency is determined. The relationship between RI and switching frequency follows the below equation within the specified RI in Kohm range at nominal loading o ...
Automotive High Brightness LED Control Based on the
Automotive High Brightness LED Control Based on the

... buck-boost switched-mode power supply. This ensures the optimal flow of current through the HBLED strings, maximizing HBLED life and avoiding undesirable visual blemishes. The microcontroller is also responsible for monitoring user inputs, battery voltage and temperature sensors, and diagnosing the ...
IntesisBox  TO-RC-MBS-1 ®
IntesisBox TO-RC-MBS-1 ®

... AC unit Temperature Setpoint (R/W) (register 5 – in PLC addressing): This is the adjustable temperature setpoint meant to be required by the user. This register can be read (Modbus function 3 or 4) or written (modbus functions 5 or 16). A remote controller connected to the AB bus of the Toshiba indo ...
IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE)
IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE)

RMF-‐1048 AC to DC Power Supply Owners Guide
RMF-‐1048 AC to DC Power Supply Owners Guide

ELECTRONIC CONTROL SYSTEMS
ELECTRONIC CONTROL SYSTEMS

Easy Calculation Yields Load Transient Response
Easy Calculation Yields Load Transient Response

... Next, select the loop-gain crossover frequency for the converter. If the loop crossover is not known, then a typical estimate would be to use one-fifth of the switching frequency. Find the intersection between the required closedloop impedance and the loop-gain crossover frequency to find the output ...
Sound DEvices MixPre-D User Guide and Technical Information
Sound DEvices MixPre-D User Guide and Technical Information

Marine Amplifier
Marine Amplifier

Service manual_VGD
Service manual_VGD

... This portion can be seen as brain of the UPS. It provides the control pulses to the switching elements which deliver power to the output. The sub-system also regulates the output to ensure that the UPS is delivering constant AC voltage to the loads. ...
RF3196 QUAD-BAND GSM850/GSM900/DCS/PCS POWER AMP MODULE Features
RF3196 QUAD-BAND GSM850/GSM900/DCS/PCS POWER AMP MODULE Features

... Building on previous generations of PowerStar® modules, the RF3196 has integrated Power Control with additional features such as VBATT tracking, and a power flattening circuit that reduces power and current variation into mismatch conditions. Theory of Operation The type of power control used in the ...
IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE)
IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE)

... the other hand, net-centriccompliance requires a “many-to-many” data exchange approach [7]. This requires a more open approach to defining interfaces,as well as the implementation of net-centric technical standardssuch as XML. ...
kit 134. introduction to lcd`s
kit 134. introduction to lcd`s

... LCD displays have a ‘busy’ flag that is set while it is executing a control command. This flag is not accessible because the R/W line has been tied low (write). This is not such a problem because all commands have a maximum execution time. We simply wait for this time to pass before accessing the LC ...
CO34543549
CO34543549

... voltage dependent load models on voltage profile and location of the SVC in power systems [7]. In case our study, each load is modeled as a stair-case dynamic load (SCDLM), in which active and reactive powers are varied at a chosen time around the base value with desired step size and realized by si ...
< 1 ... 234 235 236 237 238 239 240 241 242 ... 528 >

Control system



A control system is a device, or set of devices, that manages, commands, directs or regulates the behavior of other devices or systems. Industrial control systems are used in industrial production for controlling equipment or machines.There are two common classes of control systems, open loop control systems and closed loop control systems. In open loop control systems output is generated based on inputs. In closed loop control systems current output is taken into consideration and corrections are made based on feedback. A closed loop system is also called a feedback control system. The human body is a classic example of feedback systems.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report