• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Series 94 Peaktronics Positioner
Series 94 Peaktronics Positioner

Chapter 4 Additional Problems
Chapter 4 Additional Problems

1 .8 Differentiating EMC ferrite ↔ inductor
1 .8 Differentiating EMC ferrite ↔ inductor

Electricity Training Course
Electricity Training Course

...  Identify the types of accidents caused by electric shock.  Describe the effects on the human body of electric shock at different current levels.  Explain proper precautions against electric shock.  Identify electrical hazards related to: fuses and circuit breakers, overhead wires, exposed wirin ...
Some Examples that Use the FEM in PM Generators Analysis
Some Examples that Use the FEM in PM Generators Analysis

division 16 - Colorado College
division 16 - Colorado College

... ground terminal NOT connected to building raceway system, but grounded by an insulated green/yellow ground wire connected to "neutral-ground bonding point", in main switchboard. Ground wire may serve more than one outlet, circuit, or panel board, but connected only to loads requiring low noise groun ...
Enter o to this page the details for the document
Enter o to this page the details for the document

... We used a large flat coil of 500 turns around a 10 cm diameter former. The depth of the coil was 2 cm. Other coils such as coils from demountable transformers and intact coils from discarded ticker timers can be used, and work well. They may require some form of a guide to get the magnet through the ...
speed control - Power Electronics
speed control - Power Electronics

... Method used by electronic speed controllers  To vary the frequency supply of the motor. WHY IS VARYING THE FREQUENCY SUPPLY THE BEST METHOD?  A high performance in the whole range of speeds is obtained  This method disposes of a continuous variation of the speed, that might be electrically throug ...
Applications for Brushless DC PM Motors
Applications for Brushless DC PM Motors

Impact on power system by stationary fuel cell applications
Impact on power system by stationary fuel cell applications

... Stationary fuel cells may be used as an uninterruptible or back-up power supply or to supply a micro-grid. A microgrid with fuel cells may be an alternative to supply remote and undeveloped areas with electrical energy, before the power system is erected. Economic efficiency may be achieved more eas ...
S1000 Specific characteristics of this series:
S1000 Specific characteristics of this series:

... * Use of a bag is recommended to facilitate maintenance and extend the life of the filter and of some parts. ** Vacuums with double motorization should be outside vented. Use of Activac 2TM is not recommended. This unit can vacuum up water with the liquid interceptor only (RECU-02DVI). All illustrat ...
lab11 - University of Puget Sound
lab11 - University of Puget Sound

... motor. Follow the path of the current from the power supply around a full loop. The trick is in the "commutator," which causes the current direction to reverse each half cycle. Where does the force that drive the motor come from? Turn the power supply on, and give the moveable coil a kick to get the ...
500-1203-1
500-1203-1

Direct Torque Control of 5-Phase 10/8 Switched
Direct Torque Control of 5-Phase 10/8 Switched

... An excellent study of DTC method applied to 3phase 6/4 SRM with closest concept to the conventional DTC of ac machines was fulfilled in [11]. Authors introduced comparable theory with conventional DTC of ac machines by using motor flux and torque defining equations that will be mentioned summarily i ...
- sir cr reddy college of engineering
- sir cr reddy college of engineering

... balanced load at 0.8pf lagging the line current on the primary side is 5A.Determine the current in each coil of T/F. 8. Derive the condition for maximum torque. ...
7L02I_Pocs_RL78_Motor_Lab - Renesas e
7L02I_Pocs_RL78_Motor_Lab - Renesas e

... – ia, ib, ic phase currents – Rs stator resistance – λ magnetic flux linkage ...
- sir cr reddy college of engineering
- sir cr reddy college of engineering

... balanced load at 0.8pf lagging the line current on the primary side is 5A.Determine the current in each coil of T/F. 8. Derive the condition for maximum torque. ...
Bulk Metal® Foil Resistors
Bulk Metal® Foil Resistors

... temperature or self heating, the measured voltage drop will yield a  precise value of the current: I = V/R • But with a real‐life resistor, such as a metal film resistor or a  manganin bar, a change in current intensity (and in the dissipated  power) will cause a change in the resistor's value which ...
AN-805 APPLICATION NOTE
AN-805 APPLICATION NOTE

... Figure 5. Altering the Reference with a Resistor Divider This technique also allows different current limits to be selected at different points of operation without using multiple sense resistors. Certain systems may have a relatively low nominal current level for long periods and then go through bu ...
i. introduction
i. introduction

... current ripple, switching frequency, and two- or four-quadrant operation capability [15]–[17]. In [18], a speed-dependent switching strategy has been proposed in order to achieve fast torque response in a wide speed range. In this paper a new control method of matrix converter is proposed which uses ...
HACR Ratings and UL® Listed Molded Case Circuit
HACR Ratings and UL® Listed Molded Case Circuit

... 600 Vac and less and 250 A maximum as a second step. By these test parameters HACR Type circuit breakers were the same as other types of inverse-time circuit breakers except they were additionally investigated by UL and determined to be suitable for motor branch circuit protection on group installat ...
Sensoren und Aktoren - VLab
Sensoren und Aktoren - VLab

MN770 Evelator Application Guide
MN770 Evelator Application Guide

MP6507 - Monolithic Power System
MP6507 - Monolithic Power System

... with dual, built-in full-bridges consisting of Nchannel power MOSFETs. It operates from a supply voltage range of 2.7V to 15V, and can deliver motor current up to 700mA per channel. The internal safety features include sinking and sourcing current limits implemented with external sensors, under-volt ...
Motor torque, load torque and selection of motors
Motor torque, load torque and selection of motors

< 1 ... 67 68 69 70 71 72 73 74 75 ... 213 >

Brushed DC electric motor



A brushed DC motor is an internally commutated electric motor designed to be run from a direct current power source. Brushed motors were the first commercially important application of electric power to driving mechanical energy,and DC distribution systems were used for more than 100 years to operate motors in commercial and industrial buildings. Brushed DC motors can be varied in speed by changing the operating voltage or the strength of the magnetic field. Depending on the connections of the field to the power supply, the speed and torque characteristics of a brushed motor can be altered to provide steady speed or speed inversely proportional to the mechanical load. Brushed motors continue to be used for electrical propulsion, cranes, paper machines and steel rolling mills. Since the brushes wear down and require replacement, brushless DC motors using power electronic devices have displaced brushed motors from many applications