• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Lesson 17 DC Motors Part II
Lesson 17 DC Motors Part II

... motor must be less than the electrical power in. The most obvious electrical loss is due to the armature resistance, Pelec loss = I a2 Ra . As discussed in previous sections, power losses also occur due to: - friction between parts of the machine ...
A motor control center
A motor control center

Formating rules
Formating rules

experiment - Portal UniMAP
experiment - Portal UniMAP

ATE1120: Electrical Fundamental-II
ATE1120: Electrical Fundamental-II

... field are attracted to the opposite poles generated by the stator field and repelled by the similar poles, which causes the armature to rotate. 3. COMMUTATOR: The DC motor doesn’t use an external current switching device, instead it uses a mechanical connector called the commutator which is a segmen ...
Induction Motors
Induction Motors

... Torque-speed Characteristics-cont.  Region1: The constant torque limit region is the region below the base speed ωb, which is the lowest possible speed for the motor to operate at its rated power. For the small back-emf in this region, the current can be set at any desired level by means of regula ...
The Theory of Induction Motors
The Theory of Induction Motors

... If we look at the situation in step 1, the rotor is starting from a stand-still and has 0 RPM from the start. The lack of rotation of the rotor also means the lack of induced voltage back into the stator. This means minimal CEMF opposing the line voltage and maximum line current. As the speed of the ...
Lecture-10-11-12: Mathematical Modeling of
Lecture-10-11-12: Mathematical Modeling of

... • Another method is to vary the flux per pole of the motor. • The first method involve adjusting the motor’s armature while the latter method involves adjusting the motor field. These methods are referred to as “armature control” and “field control.” ...
- Pcpolytechnic
- Pcpolytechnic

Utilization of power factor correction capacitors in circuits
Utilization of power factor correction capacitors in circuits

... A minimum cable distance of 10 feet of cable between the capacitor(s) and the soft starter ...
SPEED CONTROL of SHUNT DC MOTOR
SPEED CONTROL of SHUNT DC MOTOR

Document
Document

...  Inverter-Duty? ...
Ventilation Structure Improvement of Air-cooled
Ventilation Structure Improvement of Air-cooled

... exploitation of the materials and the highest performance of the machine [2]. Furthermore, the thermal analysis of induction motors, due to the complexity of air course and the influence of rotation upon air-flow, cannot be accurately evaluated by using traditional lumped circuits together with empi ...
Motor Starting Characteristics of Star
Motor Starting Characteristics of Star

INDUCED DRAFT BLOWER MOTORS
INDUCED DRAFT BLOWER MOTORS

SIMOTICS Low-voltage motors - Siemens
SIMOTICS Low-voltage motors - Siemens

M.D. Sumption, J. P Murphy, N N. Gheorghiu, T. Haugan, M. Majoros
M.D. Sumption, J. P Murphy, N N. Gheorghiu, T. Haugan, M. Majoros

Characteristic Impedance Measurement
Characteristic Impedance Measurement

...  Signal reflection and distortion can be avoided between cables by matching their impedances to each other. The NIM1 standard requires that all input and output device impedances and cables impedances be 50 ohms.  But there are times when two cables or devices of two different impedances need to ...
moga tuned pi-fuzzy logic control for 3 phase induction motor with
moga tuned pi-fuzzy logic control for 3 phase induction motor with

Single Phase Induction Motor Speed Control
Single Phase Induction Motor Speed Control

Summary on detecting and decoding spinal motor neuron spike
Summary on detecting and decoding spinal motor neuron spike

Lecture-7: Modeling of Real World Systems
Lecture-7: Modeling of Real World Systems

D Speed Control Motors
D Speed Control Motors

Article PDF - Power Transmission Engineering
Article PDF - Power Transmission Engineering

... To guard against such damage and thus extend motor life, the VFD-induced current must be diverted from the bearings by means of mitigation technologies such as bearing insulation and/or an alternate path to ground. But bearing insulation and ceramic bearings do not protect attached equipment and con ...
Electromechanical Devices and Machines I– EEE 343 Department
Electromechanical Devices and Machines I– EEE 343 Department

...  Describe the construction of a d.c machine.  Understand shunt, series and compound windings of d.c machines.  Understand armature reaction.  Calculate generated emf in an armature winding  Describe types of d.c generators and their characteristics.  Calculate generated emf for a generator.  ...
< 1 ... 63 64 65 66 67 68 69 70 71 ... 113 >

Brushless DC electric motor



Brushless DC electric motor (BLDC motors, BL motors) also known as electronically commutated motors (ECMs, EC motors) are synchronous motors that are powered by a DC electric source via an integrated inverter/switching power supply, which produces an AC electric signal to drive the motor. In this context, AC, alternating current, does not imply a sinusoidal waveform, but rather a bi-directional current with no restriction on waveform. Additional sensors and electronics control the inverter output amplitude and waveform (and therefore percent of DC bus usage/efficiency) and frequency (i.e. rotor speed).The rotor part of a brushless motor is often a permanent magnet synchronous motor, but can also be a switched reluctance motor, or induction motor.Brushless motors may be described as stepper motors; however, the term stepper motor tends to be used for motors that are designed specifically to be operated in a mode where they are frequently stopped with the rotor in a defined angular position. This page describes more general brushless motor principles, though there is overlap.Two key performance parameters of brushless DC motors are the motor constants Kv and Km.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report