Motion control Lexium 32i integrated drives
... The Lexium 32i range of integrated drives covers motor power ratings between 0.4 kW and 2.1 kW with three types of power supply: bb 110…120 V single-phase, from 0.4 kW to 0.75 kW (BMIpppTppp) bb 200…240 V single-phase, from 0.7 kW to 1.3 kW (BMIpppTppp) bb 208…480 V three-phase, from 0.4 kW to 2.1 k ...
... The Lexium 32i range of integrated drives covers motor power ratings between 0.4 kW and 2.1 kW with three types of power supply: bb 110…120 V single-phase, from 0.4 kW to 0.75 kW (BMIpppTppp) bb 200…240 V single-phase, from 0.7 kW to 1.3 kW (BMIpppTppp) bb 208…480 V three-phase, from 0.4 kW to 2.1 k ...
Diagnostics - Mech-Line
... • Check for/correct faults in the input wiring. • Verify that motor cable does not exceed maximum specified length. • A delta grounded input power supply and motor cables with high capacitance may result in erroneous error reports during non-running tests. To disable response to fault monitoring whe ...
... • Check for/correct faults in the input wiring. • Verify that motor cable does not exceed maximum specified length. • A delta grounded input power supply and motor cables with high capacitance may result in erroneous error reports during non-running tests. To disable response to fault monitoring whe ...
and 2 - Faculty of Engineering
... than the primary voltage by 10, and therefore the transformer is called a step-down transformer. The purpose of this experiment is to study the behavior and circuit model of single-phase transformer as reflected by its internal parameters Running a transformer at no-load, yields a very small voltage ...
... than the primary voltage by 10, and therefore the transformer is called a step-down transformer. The purpose of this experiment is to study the behavior and circuit model of single-phase transformer as reflected by its internal parameters Running a transformer at no-load, yields a very small voltage ...
16T ESC.qxd - You have reached ftp.hobbico.com
... The following instructions will help you get trouble-free operation from your electronic speed control (ESC). These simple steps will allow your ESC to achieve maximum performance and minimize the chance of problems due to incorrect installation. Consult the specifications listed below for limitatio ...
... The following instructions will help you get trouble-free operation from your electronic speed control (ESC). These simple steps will allow your ESC to achieve maximum performance and minimize the chance of problems due to incorrect installation. Consult the specifications listed below for limitatio ...
101 basics series starters and contactors
... A contactor can stand on its own as a power control device, or as part of a starter. Contactors are used in applications ranging from the light switch to the most complex, automated industrial equipment. Contactors are used by electrical equipment that is frequently turned off and on (opening and cl ...
... A contactor can stand on its own as a power control device, or as part of a starter. Contactors are used in applications ranging from the light switch to the most complex, automated industrial equipment. Contactors are used by electrical equipment that is frequently turned off and on (opening and cl ...
CHAPTER 11
... Because the load current is zero, the only current in the armature winding is the field current. ...
... Because the load current is zero, the only current in the armature winding is the field current. ...
Self -Excited DC Motor
... hysteresis coefficient. While Eddy current loss is minimized by selecting the laminated construction for the core. ...
... hysteresis coefficient. While Eddy current loss is minimized by selecting the laminated construction for the core. ...
World in motion
... the amplifiers, the LV controllers offer the unique power of the Delta Tau position control systems. This concept provides great savings in both panel space and installation costs and whilst the design is optimised for operation using a 48VDC bus - a level that eliminates many regulatory concerns – ...
... the amplifiers, the LV controllers offer the unique power of the Delta Tau position control systems. This concept provides great savings in both panel space and installation costs and whilst the design is optimised for operation using a 48VDC bus - a level that eliminates many regulatory concerns – ...
Design and Implementation of a Hybrid Electric Bike
... decreases. This was more critical to our system, than minimizing the number of parts. Compared to other drive options, however, the two stage design is much more efficient, e.g. friction roller based approach. The advantages of a friction roller approach are its easy implementation, and high torque ...
... decreases. This was more critical to our system, than minimizing the number of parts. Compared to other drive options, however, the two stage design is much more efficient, e.g. friction roller based approach. The advantages of a friction roller approach are its easy implementation, and high torque ...
Sabertooth 2x25V2 - Dimension Engineering
... Mixed mode. This mode is designed for easy steering of differential-drive vehicles. The analog signal fed into S1 controls the forward/back motion of the vehicle, and the Switch 4: Mixed or independent analog signal fed into S2 controls the turning motion of the vehicle. If Switch 4 is in the DOWN p ...
... Mixed mode. This mode is designed for easy steering of differential-drive vehicles. The analog signal fed into S1 controls the forward/back motion of the vehicle, and the Switch 4: Mixed or independent analog signal fed into S2 controls the turning motion of the vehicle. If Switch 4 is in the DOWN p ...
DRV8809, DRV8810 User`s Guide (Rev. A
... When nSLEEP is low, the SPI_AB port is enabled and allows the user to write to the SETUP and EXTENDED registers. SPI_CD port has no function while nSLEEP is low. All H bridges are disabled, hence there is no motion control. When nSLEEP becomes high, the DRV8809/8810 enters the operational mode with ...
... When nSLEEP is low, the SPI_AB port is enabled and allows the user to write to the SETUP and EXTENDED registers. SPI_CD port has no function while nSLEEP is low. All H bridges are disabled, hence there is no motion control. When nSLEEP becomes high, the DRV8809/8810 enters the operational mode with ...
document
... Power Distribution: R2 series droids use a number of different electronic devices and not all of them require the same voltage. Many R2 units have a main 12V power supply but need a way to provide power to a number of different devices that take 5, 6 or 9 volts. The power distribution board offers a ...
... Power Distribution: R2 series droids use a number of different electronic devices and not all of them require the same voltage. Many R2 units have a main 12V power supply but need a way to provide power to a number of different devices that take 5, 6 or 9 volts. The power distribution board offers a ...
KL3518001806
... There are problems in the limitations of conventional inverters, especially in high-voltage and high-power applications. Recently multilevel inverters are becoming increasingly popular for high-power applications due to their improved harmonic profile and increased power ratings. Several studies hav ...
... There are problems in the limitations of conventional inverters, especially in high-voltage and high-power applications. Recently multilevel inverters are becoming increasingly popular for high-power applications due to their improved harmonic profile and increased power ratings. Several studies hav ...
3 - DSpace@MIT - Massachusetts Institute of Technology
... A new type of variable-reluctance motor with axially stacked stator and rotor plates is explored in this thesis. This stacked variable-reluctance motor (SVRM) has mechanically parallel air gaps, carrying magnetic flux in series. Magnetic models are developed to predict the maximum and minimum flux l ...
... A new type of variable-reluctance motor with axially stacked stator and rotor plates is explored in this thesis. This stacked variable-reluctance motor (SVRM) has mechanically parallel air gaps, carrying magnetic flux in series. Magnetic models are developed to predict the maximum and minimum flux l ...
Submersible Motors - Stallion Equipment
... in accordance with AS/NZS 3008.1.1:1998 (Electrical Installations – Selection of Cables) In Australia and New Zealand you may need to be licenced or hold a restricted licence to install, connect or disconnect an electrical appliance. Check with your state/regional electrical regulatory body first. ...
... in accordance with AS/NZS 3008.1.1:1998 (Electrical Installations – Selection of Cables) In Australia and New Zealand you may need to be licenced or hold a restricted licence to install, connect or disconnect an electrical appliance. Check with your state/regional electrical regulatory body first. ...
DC Motors and Generators Unit 2
... Figure 2-5, the magnetic poles of opposite polarity attract each other (in order to align) and the rotor starts to turn. After the rotor has turned by a certain angle, a commutation occurs and the north and south poles of the electromagnet go back. Once again, the magnetic poles of opposite polarity ...
... Figure 2-5, the magnetic poles of opposite polarity attract each other (in order to align) and the rotor starts to turn. After the rotor has turned by a certain angle, a commutation occurs and the north and south poles of the electromagnet go back. Once again, the magnetic poles of opposite polarity ...
Overload Relays
... Class 11 - 3RV manual starters and switches provide control for machinery that does not require remote start-stop control. Class 11 - 3RV switches provide control for motors where overload protection is not required or is provided separately. Class 11 - 3RV manual starters are used for single and th ...
... Class 11 - 3RV manual starters and switches provide control for machinery that does not require remote start-stop control. Class 11 - 3RV switches provide control for motors where overload protection is not required or is provided separately. Class 11 - 3RV manual starters are used for single and th ...
Modeling electric drivetrains (as covered in class)
... understanding performance of many mobile robot drivetrains. Some factors not considered in this model are gearbox characteristics, nonlinear mechanical losses, and thermal limits, which can be important in some critical applications. The torque-speed characteristics for a Maxon RE040 PMDC motor incl ...
... understanding performance of many mobile robot drivetrains. Some factors not considered in this model are gearbox characteristics, nonlinear mechanical losses, and thermal limits, which can be important in some critical applications. The torque-speed characteristics for a Maxon RE040 PMDC motor incl ...
General-Purpose Inverters and Servo Systems
... Quick response and high performance are strongly required not only by servo systems but also by generalpurpose inverters, and Fuji Electric has developed products to meet these requirements. One factor enabling the realization of high-speed control is the advance in microprocessor performance. In in ...
... Quick response and high performance are strongly required not only by servo systems but also by generalpurpose inverters, and Fuji Electric has developed products to meet these requirements. One factor enabling the realization of high-speed control is the advance in microprocessor performance. In in ...
Dial W eight Dial Weight Dynamometers
... Magtrol cannot provide standard motor mounting fixtures. We will be pleased to quote the fabrication of special fixturing for you. Contact Magtrol Customer ...
... Magtrol cannot provide standard motor mounting fixtures. We will be pleased to quote the fabrication of special fixturing for you. Contact Magtrol Customer ...
Start of pump systems
... more accurate results than most methods found in handbooks etc. This program also calculates settings/switch times for soft starters, autotransformers and star delta start. See section 4 for more information. ...
... more accurate results than most methods found in handbooks etc. This program also calculates settings/switch times for soft starters, autotransformers and star delta start. See section 4 for more information. ...
Brushless DC electric motor
Brushless DC electric motor (BLDC motors, BL motors) also known as electronically commutated motors (ECMs, EC motors) are synchronous motors that are powered by a DC electric source via an integrated inverter/switching power supply, which produces an AC electric signal to drive the motor. In this context, AC, alternating current, does not imply a sinusoidal waveform, but rather a bi-directional current with no restriction on waveform. Additional sensors and electronics control the inverter output amplitude and waveform (and therefore percent of DC bus usage/efficiency) and frequency (i.e. rotor speed).The rotor part of a brushless motor is often a permanent magnet synchronous motor, but can also be a switched reluctance motor, or induction motor.Brushless motors may be described as stepper motors; however, the term stepper motor tends to be used for motors that are designed specifically to be operated in a mode where they are frequently stopped with the rotor in a defined angular position. This page describes more general brushless motor principles, though there is overlap.Two key performance parameters of brushless DC motors are the motor constants Kv and Km.