• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
On-Line Technical Training Course
On-Line Technical Training Course

... A Gel cell is a “recombinant” battery. This means that the oxygen that is normally produced on the positive plate in all lead-acid batteries recombines with the hydrogen given off by the negative plate. The “recombination” of the hydrogen and oxygen produces water (H20), which replaces the moisture ...
Instructions for Advantage Control Modules Used with Full Voltage
Instructions for Advantage Control Modules Used with Full Voltage

... This Mandatory Off-Time Interval can be set for zero to thirty seconds by positions 1 through 4 of the DIP switch. See Table III. Set the Mandatory Off-Time Interval at the maximum consistent with the equipment being driven, since the application of power to drive the motor in one direction while it ...
MAXPLUS 211 OPTION SPINDLE AMPLIFIER
MAXPLUS 211 OPTION SPINDLE AMPLIFIER

3-Phase BLDC Motor Control with Quadrature Encoder using
3-Phase BLDC Motor Control with Quadrature Encoder using

Volume 7, Issue 2, March-April 2016, pp. 78–90, Article ID:... Available online at
Volume 7, Issue 2, March-April 2016, pp. 78–90, Article ID:... Available online at

... conventional DTC the inverter switching frequency is still low, approximately less than one third of the sampling frequency [1, 2]. The inverter switching frequency can be increased using a dithering signal, by adding a limited amplitude high frequency signal to the torque and flux error signals [3] ...
Evaluation of a Radial Flux Air-cored Permanent Magnet Machine
Evaluation of a Radial Flux Air-cored Permanent Magnet Machine

... Due to finite oil resources and its political and economical impact, a renewed interest in energy independence has compelled industry and government to pursue electric vehicle designs. The current worldwide research that is being conducted on drivetrain topologies for EVs, focus mainly on direct in-w ...
dc machine - UniMAP Portal
dc machine - UniMAP Portal

... Chapman S.J., “Electric Machinery Fundamentals” ...
Griswold Self Priming Manual
Griswold Self Priming Manual

... CLEANING THE PUMP. Run clear water through the pump if possible after pumping dirty water. Do this for two or three minutes before stopping the engine or motor. ...
Advance® 4000 Installation Manual
Advance® 4000 Installation Manual

... Mount motor base to a secure, immobile foundation. Use only plastic fittings on both the intake and discharge ports. Seal pipe connections with Teflon™ paste. These fittings should be self-supported and in neutral alignment with each port. (i.e. Fittings must not be forced into alignment which may c ...
EXPERIMENTAL INVESTIGATION Laboratory test # 1/1 Direct
EXPERIMENTAL INVESTIGATION Laboratory test # 1/1 Direct

VENF-1372i 25amp Brushless ESC_P1
VENF-1372i 25amp Brushless ESC_P1

... menu as it is presented, move the throttle stick to the full throttle position and hold for two seconds. The ESC will return to the Programming Mode and present the choices for the selected menu. You can select any of the five menu options in any order. Change everything or only the features you cho ...
Product note Medium and high voltage generators for
Product note Medium and high voltage generators for

... ABB generators have quality built in to their design, materials and manufacturing processes. Purchases are sourced from reliable vendors only and thorough testing is performed at all stages of manufacturing. Both the stator and rotor use reliable ABB form wound windings and vacuum pressure impregnat ...


... In the event that the ticker mechanism P ejects the tape at a faster rate than it is drawn - vantageous. With such an arrangement, the in formation ebtained by observation of the pro by the motor M, when energized over the circuit jection screen is almost current at times because last described, the ...
An Analytical Approach to Solving Motor
An Analytical Approach to Solving Motor

... rotational frequency. Associated with this there will be a net balanced magnetic force acting at the point of minimum air gap, since the force acting at the minimum gap is greater than the force at the maximum gap, as illustrated in Figure 5. This net unbalance force will rotate at rotational freque ...
Modeling of Saturation Due to Main and Leakage Flux
Modeling of Saturation Due to Main and Leakage Flux

... the rated operating point. The main flux saturates strongly as a function of the magnetizing current. Furthermore, it has been observed that the main flux may depend significantly on the load (or the rotor current) due to the interaction between the main flux and the rotor leakage flux [1], [2]. Thi ...
Motor Drive and Control Solutions (Rev. I)
Motor Drive and Control Solutions (Rev. I)

Losses in High Speed Permanent Magnet Machines Used
Losses in High Speed Permanent Magnet Machines Used

... loss model considering arbitrary magnetic flux waveforms can be found in Ref. 关9兴. The transient time-stepping finite element method is also widely used to directly simulate the core loss 关10,11兴. Soft magnetic materials form the magnetic circuit in an electric machine. An ideal material would have ...
Electronic Instrumentation Project 1 Instrumented Beakman`s Motor
Electronic Instrumentation Project 1 Instrumented Beakman`s Motor

... In this experiment, you will build a simple motor coil, attach it to a power source, and make it spin. You will make a simple commutator (that turns the electromagnet on and off) by sanding off only half of one of the motor leads. As the motor spins, the commutator forces the coil to appear alternat ...
dc motor control card - Country Living Grain Mills
dc motor control card - Country Living Grain Mills

Motor Drive and Control Solutions (Rev. I)
Motor Drive and Control Solutions (Rev. I)

Specification Number: 26 29 13.22
Specification Number: 26 29 13.22

Instrumented Beakman`s Motor - Rensselaer Polytechnic Institute
Instrumented Beakman`s Motor - Rensselaer Polytechnic Institute

... magnets, the more power it will obtain from the magnet. Hence, a smaller diameter coil, with a lean design will spin faster. d) Coil Weight: If the leads to your motor do not support its weight, it will not spin well. If the motor is too large and heavy, 1.5V will not provide enough power to make it ...
Chapter2 - Free-Energy-Info
Chapter2 - Free-Energy-Info

... The core material used in the electromagnets can be of various different types including advanced materials and alloys such as ‘Somalloy’ or 'Metglas'. The power pick-up coil proportions are important as an electromagnet becomes less and less effective as its length increases, and eventually, the p ...
Trade of Electrician Motor Control COURSE NOTES
Trade of Electrician Motor Control COURSE NOTES

... differ in appearance, they operate basically the same way. They are available in different IP ratings to suit the environment in which they are to be installed. Pushbuttons with ‘built in’ indicator lamps are also available. All these devices are generally known as control and signalling units. The ...
ba50/75/100 series
ba50/75/100 series

... Switches 1-4 affect the full-scale current output range of the amplifier when in current (and in velocity) mode. When all four switches are closed, the peak current range is not limited. Closing each switch effectively limits the output range of the amplifier by a factor associated with that switch. ...
< 1 ... 9 10 11 12 13 14 15 16 17 ... 113 >

Brushless DC electric motor



Brushless DC electric motor (BLDC motors, BL motors) also known as electronically commutated motors (ECMs, EC motors) are synchronous motors that are powered by a DC electric source via an integrated inverter/switching power supply, which produces an AC electric signal to drive the motor. In this context, AC, alternating current, does not imply a sinusoidal waveform, but rather a bi-directional current with no restriction on waveform. Additional sensors and electronics control the inverter output amplitude and waveform (and therefore percent of DC bus usage/efficiency) and frequency (i.e. rotor speed).The rotor part of a brushless motor is often a permanent magnet synchronous motor, but can also be a switched reluctance motor, or induction motor.Brushless motors may be described as stepper motors; however, the term stepper motor tends to be used for motors that are designed specifically to be operated in a mode where they are frequently stopped with the rotor in a defined angular position. This page describes more general brushless motor principles, though there is overlap.Two key performance parameters of brushless DC motors are the motor constants Kv and Km.