• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
WACKER - 0007896 Ø 45 mm Internal Vibrator
WACKER - 0007896 Ø 45 mm Internal Vibrator

Ground fault circuit interrupters (GFI) are circuits
Ground fault circuit interrupters (GFI) are circuits

code Description Technical specifications DL 2053A SLIP RING
code Description Technical specifications DL 2053A SLIP RING

SPH 4A - mackenziekim
SPH 4A - mackenziekim

Physics_A2_41_BackEMF
Physics_A2_41_BackEMF

... An unloaded motor will spin with a high speed, the induced back EMF will be high and the resulting current is low. The speed is limited by resistive forces (bearing friction and air resistance). Little power used In contrast a loaded motor will spin with a low speed, the induced back EMF will be lo ...
Chapter 7 - 3 phase Induction Motor
Chapter 7 - 3 phase Induction Motor

... available to the user of the machine. For steady state operation, these terminals are short circuited. ...
Subsynchronous converter cascade SCC
Subsynchronous converter cascade SCC

... It is suitable where torque is comparatively low at low speeds, and the requirements regarding control dynamics are unexacting. Examples include the drives of • centrifugal compressors • blowers • rotating pumps In these cases the power is reduced to 1/8 of the rated value at half speed. This way of ...
Lab 8 - Rose
Lab 8 - Rose

MEEPP 202 Electric Drives
MEEPP 202 Electric Drives

BSNL_TTA_Electricalspecialization
BSNL_TTA_Electricalspecialization

SECTION (ELECTRICAL) 1. In a D.C. generator, if the brushes are
SECTION (ELECTRICAL) 1. In a D.C. generator, if the brushes are

Electronics 3 Class 16 Before the availability of high power
Electronics 3 Class 16 Before the availability of high power

...  Timing of the sequence gives frequency of the output signal. - Overall View: ...
File
File

Performing locked rotor test on squirrel cage motors
Performing locked rotor test on squirrel cage motors

Prediction of Noise Generated by Electromagnetic Forces
Prediction of Noise Generated by Electromagnetic Forces

... appropriate strategy for noise control. Three main sources of sound can be identified in induction motors: mechanical noise from bearings and unbalance effects, airflow noise due to the cooling fan and magnetic noise produced by electromagnetic forces in the motor air gaps. The paper describes a pre ...
Actuators - University of Detroit Mercy
Actuators - University of Detroit Mercy

... • Current carrying conductor in magnetic field experiences force (Lorentz effect) • A conductor moved in a magnetic field generates (back) emf that opposes the change that produces it. (Faraday/Lenz’s law) • Back emf  rate of change of flux • Current due to back emf in closed circuit will create a ...
experiment - Portal UniMAP
experiment - Portal UniMAP

Induction Motors
Induction Motors

D G 220513
D G 220513

... Three phase motors should be rated for 460V wherever possible. Where building power does not include 480V distribution, review options with Project Coordinator and consider adding a step-up transformer, and using 460V motors. The long term objective in most buildings is to have three phase distribut ...
Calculation of Power factor Correction
Calculation of Power factor Correction

Advanced Dissectable and Configurable Electrical Machines AEL-EMT-KIT Technical Teaching Equipment
Advanced Dissectable and Configurable Electrical Machines AEL-EMT-KIT Technical Teaching Equipment

... • Slip ring. The slip rings collector is an essential element in this type of synchronous generators, since its function is to excite the rotor of the machine by injecting a DC current. The user can control the excitation level of the machine through a variable voltage source (N-VVCC/M. DC Motor Spe ...
18999 Demonstrate advanced knowledge of electrical
18999 Demonstrate advanced knowledge of electrical

... starting methods – pony motor, cage winding in rotor, rotor construction with damping winding, slip ring induction motor start. ...
No. CIHT:JAL:P:499(Vol.iv): Dated: / / 2010 (In reply, please quote
No. CIHT:JAL:P:499(Vol.iv): Dated: / / 2010 (In reply, please quote

code Description Technical specifications DL 2309B SPEED
code Description Technical specifications DL 2309B SPEED

The Left Hand Rule - World of Teaching
The Left Hand Rule - World of Teaching

< 1 ... 209 210 211 212 213 214 215 216 217 ... 226 >

Induction motor



An induction or asynchronous motor is an AC electric motor in which the electric current in the rotor needed to produce torque is obtained by electromagnetic induction from the magnetic field of the stator winding. An induction motor therefore does not require mechanical commutation, separate-excitation or self-excitation for all or part of the energy transferred from stator to rotor, as in universal, DC and large synchronous motors. An induction motor's rotor can be either wound type or squirrel-cage type.Three-phase squirrel-cage induction motors are widely used in industrial drives because they are rugged, reliable and economical. Single-phase induction motors are used extensively for smaller loads, such as household appliances like fans. Although traditionally used in fixed-speed service, induction motors are increasingly being used with variable-frequency drives (VFDs) in variable-speed service. VFDs offer especially important energy savings opportunities for existing and prospective induction motors in variable-torque centrifugal fan, pump and compressor load applications. Squirrel cage induction motors are very widely used in both fixed-speed and variable-frequency drive (VFD) applications. Variable voltage and variable frequency drives are also used in variable-speed service.