Intel Development Tools for Implementing UPnP Devices
... Applying Intel Development Tools for UPnP Technologies ...................................................................... 4 Service Description Authoring Using Intel Service Author .................................................................. 4 Service Templates ............................ ...
... Applying Intel Development Tools for UPnP Technologies ...................................................................... 4 Service Description Authoring Using Intel Service Author .................................................................. 4 Service Templates ............................ ...
signalling-spieff
... higher bandwidth and lower latency for (on-chip-)memory accesses. DRAM can accommodate 30 to 50 times more data than the same chip area devoted to caches. On-chip memory may be treated as main memory - in contrast to a cache which is just a redundant memory copy. PIM decreases energy consumption in ...
... higher bandwidth and lower latency for (on-chip-)memory accesses. DRAM can accommodate 30 to 50 times more data than the same chip area devoted to caches. On-chip memory may be treated as main memory - in contrast to a cache which is just a redundant memory copy. PIM decreases energy consumption in ...
PLL jitter effects on C-CAN modules of the ST10F27x
... When the magnitude of the phase error of the edge is less than or equal to the programmed value of the SJW, the results of hard synchronization and resynchronization are the same. If the magnitude of the phase error is greater than the SJW, the resynchronization cannot entirely compensate the phase ...
... When the magnitude of the phase error of the edge is less than or equal to the programmed value of the SJW, the results of hard synchronization and resynchronization are the same. If the magnitude of the phase error is greater than the SJW, the resynchronization cannot entirely compensate the phase ...
IJSR Paper Format
... 2.5 Audio Audio transmission can be performed between one or more bluetooth units, using many different usage models. Audio data do not go through the L2CAP layer but go directly, after opening a bluetooth link and a straightforward setup between two bluetooth units [9]. 2.6 Finding a Device Before ...
... 2.5 Audio Audio transmission can be performed between one or more bluetooth units, using many different usage models. Audio data do not go through the L2CAP layer but go directly, after opening a bluetooth link and a straightforward setup between two bluetooth units [9]. 2.6 Finding a Device Before ...
Aalborg Universitet HomePort ZigBee Adapter
... Device Objects (ZDO). For example this endpoint receives announcements of new devices on the network and requests for devices that support a given cluster. The ZDO module maintains a list of known ZigBee devices and queries the ZCL module for information about registered clusters. Commands specific ...
... Device Objects (ZDO). For example this endpoint receives announcements of new devices on the network and requests for devices that support a given cluster. The ZDO module maintains a list of known ZigBee devices and queries the ZCL module for information about registered clusters. Commands specific ...
Next Generation Car Network - FlexRay
... provides bounded latency, and the dynamic segment helps meet varying bandwidth requirements that can emerge at system run time. The fixed-length static segment of a FlexRay frame transfers messages with a fixed-time-trigger method, and the dynamic segment transfers messages with a flexible, time-tri ...
... provides bounded latency, and the dynamic segment helps meet varying bandwidth requirements that can emerge at system run time. The fixed-length static segment of a FlexRay frame transfers messages with a fixed-time-trigger method, and the dynamic segment transfers messages with a flexible, time-tri ...
IPv6: Hype or Reality?
... •MAC: Media Access Control address. A unique address for specific network hardware •ARP: Address resolution protocol. A standard for IPv4 devices to find one another locally •EUI-64: A unique 64-bit identifier of IPv6, based on MAC •Network Discovery (ND) Protocol: IPv6 replacement for ARP and more… ...
... •MAC: Media Access Control address. A unique address for specific network hardware •ARP: Address resolution protocol. A standard for IPv4 devices to find one another locally •EUI-64: A unique 64-bit identifier of IPv6, based on MAC •Network Discovery (ND) Protocol: IPv6 replacement for ARP and more… ...
BACnet Fundamentals Course #801
... BACnet provides a universal model for creating building automation systems which can interoperate BACnet is a specification that a manufacturer can use to make interoperable systems to work in a BACnet environment. Owners and specifiers use BACnet as a tool for specification of interoperable systems ...
... BACnet provides a universal model for creating building automation systems which can interoperate BACnet is a specification that a manufacturer can use to make interoperable systems to work in a BACnet environment. Owners and specifiers use BACnet as a tool for specification of interoperable systems ...
4 Kyung Hee University Line configuration (cont`d)
... 그물형 (cont’d) Disadvantages ~ are related to the amount of cabling and the number of I/O ports because every device must be connected to every other device, installation and reconfiguration are difficult the sheer bulk of the wiring can be greater than the available space(in walls, ceiling, or floo ...
... 그물형 (cont’d) Disadvantages ~ are related to the amount of cabling and the number of I/O ports because every device must be connected to every other device, installation and reconfiguration are difficult the sheer bulk of the wiring can be greater than the available space(in walls, ceiling, or floo ...
Dante Troubleshooting FAQ
... Note: only one such device may be configured this way on a network in order to avoid conflicting clocks. This device is automatically made the Master clock, so all others will sync to this device. All other hardware devices MUST be configured to use the Dante clock. Clock Case 2 - Using the clock in ...
... Note: only one such device may be configured this way on a network in order to avoid conflicting clocks. This device is automatically made the Master clock, so all others will sync to this device. All other hardware devices MUST be configured to use the Dante clock. Clock Case 2 - Using the clock in ...
Device Management System
... with Company, billing will occur when the first data transmission occurs, such as SMS, MicroBurst, or an IP session. All transmissions will be charged. This typically applies to devices that are under test and development, but have not yet been commercially released on the Company network. • For dev ...
... with Company, billing will occur when the first data transmission occurs, such as SMS, MicroBurst, or an IP session. All transmissions will be charged. This typically applies to devices that are under test and development, but have not yet been commercially released on the Company network. • For dev ...
Discovering Devices using HP Web Jetadmin
... New in HP Web Jetadmin discovery ....................................................................................... 3 Part 1—How discovery works .................................................................................................... 3 Discovery settings ............................ ...
... New in HP Web Jetadmin discovery ....................................................................................... 3 Part 1—How discovery works .................................................................................................... 3 Discovery settings ............................ ...
Aalborg Universitet Synthesis of variable harmonic impedance in inverter-interfaced distributed generation
... To make the DG unit operate in both grid-connected and islanded operation, the output voltage of DG inverter needs to be controlled. Then, the dynamic behavior of the closed-loop output voltage control system has an important effect on the harmonic distortions of distribution system. The closed-loop ...
... To make the DG unit operate in both grid-connected and islanded operation, the output voltage of DG inverter needs to be controlled. Then, the dynamic behavior of the closed-loop output voltage control system has an important effect on the harmonic distortions of distribution system. The closed-loop ...
Physical and logical topologies. LAN devices.
... star topologies together. • At the center of the star is a hub or a switch. • Extends the length and size of the network. ...
... star topologies together. • At the center of the star is a hub or a switch. • Extends the length and size of the network. ...
1 Dear customers of Eberspächer Electronics, the worst of the
... The application allows to create a gateway application automatically for any ECU, using a FIBEX database. Different gateway configurations, such as FlexRay/FlexRay, CAN/FlexRay and CAN/CAN, are possible. This means that, for instance, FlexRay ECUs can be tested on existing CAN HiL systems, both duri ...
... The application allows to create a gateway application automatically for any ECU, using a FIBEX database. Different gateway configurations, such as FlexRay/FlexRay, CAN/FlexRay and CAN/CAN, are possible. This means that, for instance, FlexRay ECUs can be tested on existing CAN HiL systems, both duri ...
7 10 Gigabit Ethernet Performance with Various
... The round trip latency, shown in Figure 4.1 as a function of the packet size, is a smooth function for both 33 MHz and 66 MHz PCI buses, indicating that the driver-NIC buffer management works well. The clear step increase in latency at 1500 bytes is due to the need to send a second partially filled ...
... The round trip latency, shown in Figure 4.1 as a function of the packet size, is a smooth function for both 33 MHz and 66 MHz PCI buses, indicating that the driver-NIC buffer management works well. The clear step increase in latency at 1500 bytes is due to the need to send a second partially filled ...
USB/IP - a Peripheral Bus Extension for Device Sharing
... uses the low-level control protocols of the peripheral devices, which are the same as those of locally attached devices. These protocols, which are defined by several standards, are independent of the operating system implementation. By using these protocols for sharing, computers with different ope ...
... uses the low-level control protocols of the peripheral devices, which are the same as those of locally attached devices. These protocols, which are defined by several standards, are independent of the operating system implementation. By using these protocols for sharing, computers with different ope ...
The Standard IEEE 1588
... this presentation (according to workshop planning) this requires some compromises to be accepted the big advantage to be exploited is that the same infrastructure can be used for both data transmission and synchronization ...
... this presentation (according to workshop planning) this requires some compromises to be accepted the big advantage to be exploited is that the same infrastructure can be used for both data transmission and synchronization ...
An active star topology for CAN networks
... Some of the faults presented above can be confined in bus systems, up to a certain extent, using techniques that are already known. These techniques rely on the use of replicated transmission media as well as on the use of bus guardians. However, they do not guarantee that a single component fault n ...
... Some of the faults presented above can be confined in bus systems, up to a certain extent, using techniques that are already known. These techniques rely on the use of replicated transmission media as well as on the use of bus guardians. However, they do not guarantee that a single component fault n ...
Data Sheet
... The M-Bus gateway detects all kinds of meters such as electric, gas, heat, water and others. It supports M-Bus meters types, Mode1, Mode 2, “Fixed Data Response” and “Variable Data Response” types. Every single M-Bus meter record can be explicit configured to be converted to a BACnet Analog Object. ...
... The M-Bus gateway detects all kinds of meters such as electric, gas, heat, water and others. It supports M-Bus meters types, Mode1, Mode 2, “Fixed Data Response” and “Variable Data Response” types. Every single M-Bus meter record can be explicit configured to be converted to a BACnet Analog Object. ...
Butler - e:cue
... Butler - Hardware Installation 3.3 Connecting Power Connect the adaptor to the power input. The Butler can handle currents between 12 volts (minimum) and 24 volts (maximum) AC or DC. When the Butler is powered up, the display shows a small turning circle or the message “boot” (displayed “b”-”o”-”o ...
... Butler - Hardware Installation 3.3 Connecting Power Connect the adaptor to the power input. The Butler can handle currents between 12 volts (minimum) and 24 volts (maximum) AC or DC. When the Butler is powered up, the display shows a small turning circle or the message “boot” (displayed “b”-”o”-”o ...
Introduction - MTEE Server
... To avoid passwords being shown in clear text in the output from the show running-config or show startup-config commands: Router(config)# service password-encryption NESCOT CATC ...
... To avoid passwords being shown in clear text in the output from the show running-config or show startup-config commands: Router(config)# service password-encryption NESCOT CATC ...
Low Pin Count
The Low Pin Count bus, or LPC bus, is used on IBM-compatible personal computers to connect low-bandwidth devices to the CPU, such as the boot ROM, ""legacy"" I/O devices (integrated into a super I/O chip), and Trusted Platform Module (TPM). ""Legacy"" I/O devices usually include serial and parallel ports, PS/2 keyboard, PS/2 mouse, and floppy disk controller.Most PC motherboards with a LPC bus have either a Platform Controller Hub (PCH) or a southbridge chip, which acts as the host and controls the LPC bus. All other devices connected to the physical wires of the LPC bus are peripherals.