• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Notes on Computerized Tomography
Notes on Computerized Tomography

... If a dose of radiation of unusually large quantity (over 100 rads) is delivered to the body in a very short time, biological effects that occur within hours or days after irradiation are referred to as short-term effects. The signs and symptoms of these effects include nausea, vomiting, malaise, and ...
the impact of positron emission tomography/computed tomography
the impact of positron emission tomography/computed tomography

... Positron emission tomography (PET) with the glucose analog 18F-fluoro-2-deoxy-D-glucose (FDG) is a functional imaging method that detects areas of increased glucose metabolism. Because neoplastic cells overexpress glucose transporters and are, therefore, characterized by increased glucose uptake, mo ...
171.pdf
171.pdf

... We have used Rueckert’s single-level FFD method at a range of different B-spline control point resolutions of 20mm, 15mm, 10mm, and 5mm, and our new framework with the same set of resolutions, but in a hierarchical manner. Fig. 2 shows example registration results for the patient and FEM simulation ...
Nuclear Medicine Technologist Performance Standards
Nuclear Medicine Technologist Performance Standards

... PET and SPECT to provide physicians with a way to look inside the body without surgery. Diagnostic imaging is considered a non-invasive diagnostic technique, as opposed to a biopsy or exploratory surgery. PET, SPECT and some types of MR imaging also provide information about how certain tissues and ...
(2011/65/EU) with the changes from January 2014
(2011/65/EU) with the changes from January 2014

... Lead in alloys, as a superconductor or thermal conductor, used in cryocooler cold heads and/or in cryo-cooled cold probes and/or in cryo-cooled equipotential bonding systems, in medical devices (category 8) and/or in industrial monitoring and control instruments. Expires on 30 June 2021. Hexavalent ...
Mammoscintigraphy
Mammoscintigraphy

... Matching array of photodiodes replaces PMTs and detects the scintillation light that results when a gamma ray is absorbed. Digital imaging where CsI(Tl) replaces NaI(Tl) Reduced camera/detector size Improved spatial resolution Compact size allows for closer and varied angles Less expensive system ...
Here - CAI2R
Here - CAI2R

... dimensions for y are [Nread-Nproj-Nz-Ncoil-Nbin], where Ncoil equals the number of receive channels, Nproj the number of projections per motion state and Nread the number of readout samples. S is the sparsifying transform applied along the respiratory dimension. In this work, temporal finite differe ...
ORIGINAL ARTICLE ORIG ORIGI CT for upper abdominal pathology
ORIGINAL ARTICLE ORIG ORIGI CT for upper abdominal pathology

... In addition the hepatic phase is extended to include the whole abdomen, and possibly pelvis, to evaluate for extrahepatic disease.15 In one of our patients diagnosed with hepatocellular carcinoma pelvic bone and lumbar vertebral metastases (L5), would not have been diagnosed had the pelvis not been ...
An Opportunity for Radiology
An Opportunity for Radiology

... interpretive services at the same level of quality as do radiologists, or to detect abnormalities other than those specific to their specialty. This reduction in accuracy puts patients at risk, increases the cost of health care, and erodes the public’s confidence in the quality and safety of imaging ...
THE VETERINARY PUBLISHING COMPANY
THE VETERINARY PUBLISHING COMPANY

... use of an anti-scatter grid. Although there are several beam-restricting devices, the one that is most commonly used in veterinary practice and the one that has been used in this handbook, is the variable aperture collimator with a light beam diaphragm that makes it possible to collimate the exposur ...
The Advanced Modalities ~ Magnetic Resonance Imaging
The Advanced Modalities ~ Magnetic Resonance Imaging

... away from its powerful magnetic field. – Most magnets used today have strengths ranging from 0.1-3.0 Tesla. Stronger magnets generally allow for better resolution on images, because they produce a stronger “signal” (see below), but they tend to be more enclosed. • The gradient magnet – This componen ...
Multimodality Molecular Imaging with Combined Optical and SPECT
Multimodality Molecular Imaging with Combined Optical and SPECT

... a signal-to-background ratio higher than that achieved with simple planar fluorescence imaging (2). Fluorescence imaging is most commonly performed with reflectance planar geometry for simplicity and speed. In fluorescence reflectance imaging (FRI), the light source and detector are on the same sid ...
Interventional Radiology 2013 - Angio CT Studies Update (PDF:1.60
Interventional Radiology 2013 - Angio CT Studies Update (PDF:1.60

... those who underwent examination without it (P<0.0001).2 The survival rate was higher when focusing solely on patients with stage I HCC (P=0.0093) or those who underwent TACE (P=0.0023). Cone-beam CT also improved outcomes of patients undergoing ultraselective TACE as treatment for small HCC lesions ...
Positron Emission Tomography (PET) Technologist Scope of
Positron Emission Tomography (PET) Technologist Scope of

... volume of x-ray–based images, generally reconstructed as two-dimensional (2D) or threedimensional (3D) pictures of inside the body. These images can be rotated and viewed from any angle. Each CT image is effectively a single “slice” of anatomy. Diagnostic Imaging: Diagnostic imaging uses technologie ...
Final PET SOP - Society of Nuclear Medicine
Final PET SOP - Society of Nuclear Medicine

... multiple 2-D images ( ) from multiple angles. Tomographic reconstruction algorithms are applied to the multiple projections, yielding a 3-D dataset. This dataset may then be manipulated to show thin slices along any chosen axis of the body, similar to those obtained from other tomographic techniques ...
02. PET/CT Technology
02. PET/CT Technology

... Computed Tomography (CT) imaging provides high quality images which reproduce transverse cross sections of the body. Tissues are therefore not superimposed on the image as they are in conventional projections The technique offers improved low contrast resolution for better visualization of soft tiss ...
Modul 1_Radiologycal diagnostic and therapy
Modul 1_Radiologycal diagnostic and therapy

... Name a method of radial therapy at which use the radiation source can rotate around the patient A. Therapy by a break radiation of high energies B. Selective accumulation of an isotope C. Intracavitary beta-ray therapy D. Short-distance gamma therapy E. * Long-distance gamma therapy Specify philosop ...
Novation Diagnostic Imaging Watch Product and
Novation Diagnostic Imaging Watch Product and

... increased emphasis on radiation safety, particularly in the United States, which has created the need for better dose tracking and monitoring tools. In California, legislation passed July 1, 2012, with new requirements for computed tomography scanners. A facility using CT scanners now must track dos ...
TOF法とFSBB法の組み合わせによるhybrid MRA の初期臨床応用
TOF法とFSBB法の組み合わせによるhybrid MRA の初期臨床応用

... confirmed that, by using 8 mL each, consecutive acquisition of TCMRA and PWI could yield images of sufficient diagnostic value As for PWI, it has been reported that, as extravasation of contrast agent due to disruption of the blood-brain barrier occurs in some tumors, the administration of a predose ...
American Institute for Cancer Research
American Institute for Cancer Research

... "We are very excited by these findings," she says, "and are now trying to understand the mechanism by which soy increases the effect of radiation on tumors while at the same time protecting normal tissue from radiation." ...
CT Angiography (CTA)
CT Angiography (CTA)

... plate. Bones appear white on the x-ray; soft tissue shows up in shades of gray and air appears black. With CT scanning, numerous x-ray beams and a set of electronic x-ray detectors rotate around you, measuring the amount of radiation being absorbed throughout your body. At the same time, the examina ...
JCST Residency Programme Nuclear Medicine
JCST Residency Programme Nuclear Medicine

... meet specific outcomes in the 7 core competencies of patient care, medical knowledge, practicebased learning and improvement, interpersonal and communication skills, professionalism , systembased practice and faculty development. The Nuclear Medicine Residency Program is structured in such a way tha ...
Detector technology in simultaneous spectral
Detector technology in simultaneous spectral

... quantification and provides the ability to characterize structures based on material content, helping provide clinicians with additional information for their diagnosis. ...
Fetal magnetic resonance imaging: jumping from 1.5 to 3 tesla
Fetal magnetic resonance imaging: jumping from 1.5 to 3 tesla

... it is fair to assume that they are also longer at 3 T than at 1.5 T. If the same signal strength is to be maintained, repetition time should be increased. However an increase in repetition time results in unwanted increased acquisition time and potentially worsening motion artifact of a highly mobil ...
Identification of Prognostic Markers in Bone Sarcomas Using Proton
Identification of Prognostic Markers in Bone Sarcomas Using Proton

... Department of 1Medical Physics, 2Pediatrics, 3Radiology, 4Orthopedic Surgery, 5Biostatistics, 6Medicine, and 7Pathology, Memorial Sloan-Kettering Cancer Center, New York, New York ...
< 1 ... 83 84 85 86 87 88 89 90 91 ... 173 >

Image-guided radiation therapy

Image-guided radiation therapy (IGRT) is the process of frequent two and three-dimensional imaging, during a course of radiation treatment, used to direct radiation therapy utilizing the imaging coordinates of the actual radiation treatment plan. The patient is localized in the treatment room in the same position as planned from the reference imaging dataset. An example of IGRT would include localization of a cone beam computed tomography (CBCT) dataset with the planning computed tomography (CT) dataset from planning. IGRT would also include matching planar kilovoltage (kV) radiographs or megavoltage (MV) images with digital reconstructed radiographs (DRRs) from the planning CT. These two methods comprise the bulk of IGRT strategies currently employed circa 2013.This process is distinct from the use of imaging to delineate targets and organs in the planning process of radiation therapy. However, there is clearly a connection between the imaging processes as IGRT relies directly on the imaging modalities from planning as the reference coordinates for localizing the patient. The variety of medical imaging technologies used in planning includes x-ray computed tomography (CT), magnetic resonance imaging (MRI), and positron emission tomography (PET) among others. The precision of IGRT is significantly improved when N-localizer technology is used in conjunction with these medical imaging technologies. Through advancements in imaging technology, combined with a further understanding of human biology at the molecular level, the impact of IGRT on radiotherapy treatment continues to evolve.