• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
- Braincon
- Braincon

... Abstract Nowadays, conventional or digitalized teleradiography remains the most commonly used tool for the study of the sagittal balance, sometimes with secondary digitalization. The irradiation given by this technique is important and the photographic results are often poor. Some radiographic table ...
X-ray Tube and Generator
X-ray Tube and Generator

... neutralised and become Ag atoms (sensitised grains). The combination of areas in the film with different number of sensitised grains forms a LATENT IMAGE. During the process of film development the sensitised grains are stabilised (the exposed AgBr crystals are reduced to stable Ag atoms). During th ...
with Pantomography in the Assessment
with Pantomography in the Assessment

... omography provides a three-dimensional unobstructed and anatomically accurate picture of the region being viewed. Tomography is a radiographic technique in which a "slice" or section of a given internal body structure is imaged in a pre-determined plane. The advantage of utilizing a tomographic eval ...
Liver lesion conspicuity during realtime MRguided radiofrequency
Liver lesion conspicuity during realtime MRguided radiofrequency

... (BCLC) staging classification and the American Association of the Study of Liver Diseases (AASLD) (6,7). Thermal ablations are also the first choice of treatment for unresectable isolated hepatic metastases. Image guidance plays a key role in accurate applicator placement and in ensuring a targeted, ...
Compendium of Critical Limb Ischemia (CLI) in Peripheral Arterial Disease
Compendium of Critical Limb Ischemia (CLI) in Peripheral Arterial Disease

... Distinguishing acute vs. chronic CLI is vital for imaging purposes and management Effective noninvasive non-imaging techniques to assess PAD in outpatient setting are segmental doppler and plethysmography Remember the purpose of imaging is not only to confirm diagnosis but also to map out options fo ...
Ultrasonic and X-ray Tomographic Imaging of Highly Contrasting
Ultrasonic and X-ray Tomographic Imaging of Highly Contrasting

... 2000a, 2000b; Pla-Rucki and Eberhard 1995; Braz et al. 1999; Masad et al. 2002; Wang 2003; Al-Raoush and Willson 2004; Al-Omari and Masad 2004). XCT systems used in the microstructure characterization of concrete usually have a large penetrating capability and high resolution up to 5-10 micrometers. ...
Inside Biograph TruePoint PET•CT
Inside Biograph TruePoint PET•CT

... LSO: state-of-the-art crystal technology With more than 10 years of experience in Lutetium Oxyorthosilicate (LSO) scintillator crystal technology, Siemens is a pioneer in innovative PET imaging techniques. The Biograph TruePoint PET·CT employs patented LSO PET detectors that provide clear and fast i ...
Chapter 7
Chapter 7

... – Deeper – ______ – Lesser pubic arch – Narrow inlet – Oval ________Foramen ...
Recent Advances in Pulmonary Imaging
Recent Advances in Pulmonary Imaging

... identified prospectively by MRA. Of the six clots that were missed by MRA, four were subsegmental. Clearly MRA has a high sensitivity and specificity for central, lobar, and segmental vessels but has limitations, which are similar to CT, in its ability to detect subsegmental clots. MRA has the addit ...
technique - Montgomery College
technique - Montgomery College

... • Variable kVp, Fixed mAs– short contrast/more pt exposure • Fixed kVp, Variable mAs – Prefered, longer contrast less patient exposure • High kVp chart – For exams using 100 kVp or higher • Automatic exposure-PATIENT POSITIONING --VERY IMPORTANT ...
Diffusion-weighted MRI of urinary bladder and prostate cancers
Diffusion-weighted MRI of urinary bladder and prostate cancers

... of the ADC values of tumors and bladder wall in our study, there was a small amount of overlap, and we could not determine a cut-off point for the detection of malignancy. In another study, El-Assmy et al. (15) found both sensitivity and specificity of 100% for DWI in the detection of superficial bl ...
A Hand-Held, Intra-Operative Positron Imaging Probe for
A Hand-Held, Intra-Operative Positron Imaging Probe for

... Image-guided surgery has gained tremendous attention in recent years and spans over a range of technologies such as radiotracer- and optical based imaging modalities. Near infrared (NIR) fluorescence imaging falls into the latter category and is based on utilizing light photons at the 700-900 nm rang ...
Summary of Public Comment
Summary of Public Comment

... require significant downtime and inevitably affect patient care. With 10 critical access hospitals in the Upper Peninsula with only a single scanner, the time required to comply with this rule would potentially be days before the CT scanner is up and running. The risk to patients and their subsequen ...
PO3 Supervisor – Magnetic Resonance Imaging
PO3 Supervisor – Magnetic Resonance Imaging

... Operate under general policy direction and with a high level of professional independence in the determination of operational priorities, strategies, work standards and allocation of resources for MRI Level 6. Responsible for allocating and determining work priorities of the MRI team rostered to Lev ...
X enon X e 133 Gas - Mallinckrodt Pharmaceuticals
X enon X e 133 Gas - Mallinckrodt Pharmaceuticals

... standard, such as Americium Am 241, at that time for subsequent routine use. Other suitable radionuclides may also be used. Determine the effective readout of the secondary standard compared to the Xenon Xe 133 standard over the range of activities expected for routine measurements. Determine the ra ...
58-31-ET-V1-S1__intr.. - e-Acharya Integrated E
58-31-ET-V1-S1__intr.. - e-Acharya Integrated E

... • a pre-weighting of the projection data, depending on  • a pre-weighting of the filter (here we used the spatial domain filters) • a backprojection along the fan-beam rays (interpolation as usual) • a weighting of the contributions at the reconstructed pixels, depending on their distance v(x, y) f ...
Three-dimensional Dose Verification Using Normoxic Polymer Gel
Three-dimensional Dose Verification Using Normoxic Polymer Gel

... linear relationship with dose was present from 0 to 6.5 Gy. One group of gel samples were measured in near real-time, in which the gel phantom was read right after the irradiation. The other group was measured 12 hours after irradiation so the gel phantom can be exposed to oxygen. Several post-imagi ...
3D Rapid CT Reconstruction
3D Rapid CT Reconstruction

... • a pre-weighting of the projection data, depending on  • a pre-weighting of the filter (here we used the spatial domain filters) • a backprojection along the fan-beam rays (interpolation as usual) • a weighting of the contributions at the reconstructed pixels, depending on their distance v(x, y) f ...
INTRODUCTION TO CHEST IMAGING
INTRODUCTION TO CHEST IMAGING

... PLAIN RADIOGRAPHY OF THE CHEST (CXR) • CRITERIA OF A GOOD X-RAY OF THE CHEST • Patient central – a-Sterno-clavincular junction equidistant from midline (spinous process). – b-Mediasternum 2/3 to left and 1/3 to right • Lung apices appear and lower 3 cervical vertebrae. • The diaphragm should be fou ...
Diffusion Tensor Imaging and Tractography Technical Considerations
Diffusion Tensor Imaging and Tractography Technical Considerations

... have wraparound) due to their small FOV. Image domain parallel imaging techniques work by unfolding and combining these images to form the full FOV image. However, SENSE and ASSET both require a calibration scan performed before DWI to estimate the sensitivity profiles of each of the coil elements. ...
radiology services - Ministry of Health
radiology services - Ministry of Health

... the inside of the body. MRI scans can show bones, muscles, joints, blood vessels, nerves and other structures in great detail. The key component of MRI scanners is the magnet, which determines the scanner’s Field Strength, and is rated using a unit of measure known as a Tesla. Higher Field Strength ...
D. Design and Methods - Surgical Planning Laboratory
D. Design and Methods - Surgical Planning Laboratory

... use preoperatively acquired images to create anatomical models, which provide localization, targeting and visualization of the three-dimensional (3D) anatomy. These models support preoperative planning to define and optimize access strategies as well as the simulation of planned intervention. When r ...
1 - Healthcare Improvement Scotland
1 - Healthcare Improvement Scotland

... melanoma, oesophageal cancer and breast cancer and is considering extending its reimbursement to include some central nervous system tumours. A number of countries have undertaken HTAs of FDG-PET in cancer. Most have reached similar conclusions that FDG-PET is more accurate than conventional technol ...
Integration of FDG-PET/CT into external beam radiation therapy
Integration of FDG-PET/CT into external beam radiation therapy

... the image resolution can still be detected in PET if the contrast between lesion and surrounding tissue is sufficiently high. The CT components of combined PET/ CT are typically multi-slice CT systems with up to 128 slices being acquired simultaneously and a maximum axial coverage of 8 cm per rotati ...
radiation protection in diagnostic radiology
radiation protection in diagnostic radiology

... by receiving radiation over a larger volume. Irradiating a smaller volume also minimizes the amount of scattered radiation and improves image contrast. • When using equipment without automatic X Ray beam collimation, it should be verified that the radiation field is reduced up to the smallest size c ...
< 1 ... 60 61 62 63 64 65 66 67 68 ... 173 >

Image-guided radiation therapy

Image-guided radiation therapy (IGRT) is the process of frequent two and three-dimensional imaging, during a course of radiation treatment, used to direct radiation therapy utilizing the imaging coordinates of the actual radiation treatment plan. The patient is localized in the treatment room in the same position as planned from the reference imaging dataset. An example of IGRT would include localization of a cone beam computed tomography (CBCT) dataset with the planning computed tomography (CT) dataset from planning. IGRT would also include matching planar kilovoltage (kV) radiographs or megavoltage (MV) images with digital reconstructed radiographs (DRRs) from the planning CT. These two methods comprise the bulk of IGRT strategies currently employed circa 2013.This process is distinct from the use of imaging to delineate targets and organs in the planning process of radiation therapy. However, there is clearly a connection between the imaging processes as IGRT relies directly on the imaging modalities from planning as the reference coordinates for localizing the patient. The variety of medical imaging technologies used in planning includes x-ray computed tomography (CT), magnetic resonance imaging (MRI), and positron emission tomography (PET) among others. The precision of IGRT is significantly improved when N-localizer technology is used in conjunction with these medical imaging technologies. Through advancements in imaging technology, combined with a further understanding of human biology at the molecular level, the impact of IGRT on radiotherapy treatment continues to evolve.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report