• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Making the difference with Live Image Guidance - InCenter
Making the difference with Live Image Guidance - InCenter

... The DoseAware dose monitoring system provides real-time X-ray dose feedback that is displayed during a procedure, so staff can immediately adjust working habits to support radiation exposure management3. A time-stamped record of where and when X-ray dose was acquired is created. ...
BASE OF TONGUE CANCER
BASE OF TONGUE CANCER

... neck immobilization device was used to maximize reproducibility of the head and chin position (Figure 18.4-3A; AccuForm, MED-TEC Inc., Orange City, IA). In addition, the shoulders were immobilized by having the patient hold on to two hand dowels or pegs on a customized plastic board. The location of ...
Michael F. McNitt-Gray, PhD: CT imaging as a biomarker: the role of
Michael F. McNitt-Gray, PhD: CT imaging as a biomarker: the role of

... – Assess change in size using tumor volumes – What about change in other measures/characteristics ...
Anatomy and Physiology BIO 137
Anatomy and Physiology BIO 137

... doughnut standing on its side, and the person lies on the table in the center. 1) The X-ray tube rotates around the body. 2) The table slowly moves through the inside of the machine. 3) Each rotation yields several images of thin slices of the body. ...
Imaging in oncology - over a century of advances
Imaging in oncology - over a century of advances

... was found to be very useful in oncological imaging almost by chance, with the first oncological PET image being presented in 1991, using FDG as a radiotracer. To this day oncological imaging is by far the major use of PET in worldwide clinical practice. ...
New Joint Commission Radiology Standards
New Joint Commission Radiology Standards

... tomography (PET), or nuclear medicine (NM) services: Prior to installation of new imaging equipment, replacement of existing imaging equipment, or modification to rooms where ionizing radiation will be emitted or radioactive materials will be stored (such as scan rooms or hot labs), a medical physic ...
Fun Dx Penguine Points
Fun Dx Penguine Points

... -magnification mode results in better spatial resolution, better contrast resolution, and higher patient dose (this is because when we magnify, the image becomes dimmer. The ABC corrects for this by pumping up the mA) -vignetting  at the periphery of any magnified image, there is a reduction in br ...
An Imaging Process for Early Detection of Colorectal Cancer Using
An Imaging Process for Early Detection of Colorectal Cancer Using

... intestine using Compton backscattering of X-ray and gamma radiation emitted from a radioactive source. The new imaging process should become a part of the periodic screening program for early detection of colorectal cancer in men and women aged 50 years and more. This study presents an estimate of t ...
Introduction to Radiology
Introduction to Radiology

... gall bladder showing a gall stone ...
Applications of Cone Beam Computed Tomography in
Applications of Cone Beam Computed Tomography in

... CBCT machines have 2 major differences compared with so-called “medical” CT scanners. First, CBCT uses a low-energy fixed anode tube, similar to that used in dental panoramic x-ray machines. Second, CBCT machines rotate around the patient only once, capturing the data using a cone-shaped x-ray beam. ...
effective physics education for optimizing ct image quality and dose
effective physics education for optimizing ct image quality and dose

... continuing advances in technology there is the capability to produce images with characteristics that can be optimized for a wide range of clinical purposes. Also, there is the need to manage the radiation dose for each patient and balance it with respect to the image quality requirements. This is a ...
EXAM: MYOVIEW STRESS TEST (ADENOSINE or LEXISCAN
EXAM: MYOVIEW STRESS TEST (ADENOSINE or LEXISCAN

... identity, explain the procedure, and review their history. An IV will be started. The patient will receive an injection and wait a minimum of 30 minutes before imaging. The imaging lasts about 15-20minutes. The patient will then go to the stress lab area where the patient will wait until the patient ...
Microsoft Word Conversion Template
Microsoft Word Conversion Template

... Standing and walking is frequent within the clinic, when organising materials and equipment, when tending to patients, and when preparing radio-active materials. Sitting at an office desk or computer, if used for record-keeping, may be frequent. Stretching and reaching across is likely to be occasio ...
FLUOROSCOPY MODULE Jenniefer Kho, MD
FLUOROSCOPY MODULE Jenniefer Kho, MD

... Collimator - contains multiple sets of shutter blades that define the shape of the x-ray beam. There is a rectangular and a round set of blades. By further collimating the beam, or "coning down" to the area of interest, the exposed volume of tissue is reduced, which results in less scatter productio ...
Learning objectives
Learning objectives

... “As low as reasonably achievable” General principle guiding radiation exposure Keep radiation dose exposure to patient as low as reasonable for each procedure, given clinical need and patient factors ...
the First Positron Emission tomography–Magnetic Resonance
the First Positron Emission tomography–Magnetic Resonance

... Correspondence: Dr Solomon Ka, Department of Diagnostic and Interventional Radiology, Hong Kong Sanatorium and Hospital, 1/ ...
Female Pelvis: Tips and Tricks for Pelvic Imaging Patricia
Female Pelvis: Tips and Tricks for Pelvic Imaging Patricia

... echo or fast gradient recalled echo. DWI is interesting in the setting of neoplasm, knowing that most cancers will cause diffusion restriction. These sequences are useful in the initial identification of tumors as well as treatment response evaluation, especially in the setting of adnexal and uterin ...
PAT IENT INFOR MAT ION: HEAMA NGIO MA SCAN
PAT IENT INFOR MAT ION: HEAMA NGIO MA SCAN

... If you cannot attend on the day, please call the Department to make another appointment time. ...
Brochure
Brochure

... - A larger, better-performing sensor (flat panel) allows investigation of volumes of up to 24x19 cm with an improved signal/noise ratio; ; - A rotating-anode generator with a focal spot of 0.3 mm, suitable for low-exposure high-definition protocols, for post-operative checks and follow-ups. This pro ...
BBS 3220 Application of Radioimmunoassay and Imaging
BBS 3220 Application of Radioimmunoassay and Imaging

... BBS 3220 Application of Radioimmunoassay and Imaging techniques Course description This course covers the instruments, reagents and methods used in radioimmunoassay and radio imaging of internal organs. It also brings out the major diagnostic and therapeutic procedures carried out using radioisotope ...
Medical Imaging Services
Medical Imaging Services

... CT shields for the chest, eye and thyroid areas. Medical shields reduce harmful radiation exposure by up to 57 percent and do not sacrifice the quality of the resulting images. Computed Tomography (CT Scan) Computed Tomography, sometimes called a CAT Scan, uses special x-ray equipment to obtain many ...
x-ray imaging - X-ICAD
x-ray imaging - X-ICAD

... E-mail: [email protected] Website: www.x-icad.co.za ...
89( اردﻳﺒﻬﺸﺖ ) ﻴﻨﺎل ﺧﺮﻳﺪاري ﺷﺪه از ﻧﻤﺎﻳﺸﮕﺎه ﻛﺘﺎب ﺟ ﻟﻴﺴﺖ
89( اردﻳﺒﻬﺸﺖ ) ﻴﻨﺎل ﺧﺮﻳﺪاري ﺷﺪه از ﻧﻤﺎﻳﺸﮕﺎه ﻛﺘﺎب ﺟ ﻟﻴﺴﺖ

... Organic Synthesis with Enzymes in Non-Aqueous Media Practical: microwave synthesis for orgnic chemists; strategies instruments , and ...
CTbushong2
CTbushong2

... Third Generation A fan beam x-ray source is used and it views the entire patient during imaging  As many as several hundred radiation detectors are incorporated into the curvilinear detector array  The curvilinear detector array provides constant distance between source and each detector, resulti ...
RADIOLOGY The coursework of Radiology and Diagnostic Imaging
RADIOLOGY The coursework of Radiology and Diagnostic Imaging

... Weissleder R., et al.: Primer of Diagnostic Imaging. 4th ed, Mosby Elsevier, 2007. Gibson R, et al.: Essential Medical Imaging. Cambridge University Press, 2009. Moeller T.B., Reif E.: Pocket Atlas of Sectional Anatomy, Computed Tomography and Magnetic Resonance Imaging, Vol. 1-3. Thieme Verlag, 200 ...
< 1 ... 147 148 149 150 151 152 153 154 155 ... 173 >

Image-guided radiation therapy

Image-guided radiation therapy (IGRT) is the process of frequent two and three-dimensional imaging, during a course of radiation treatment, used to direct radiation therapy utilizing the imaging coordinates of the actual radiation treatment plan. The patient is localized in the treatment room in the same position as planned from the reference imaging dataset. An example of IGRT would include localization of a cone beam computed tomography (CBCT) dataset with the planning computed tomography (CT) dataset from planning. IGRT would also include matching planar kilovoltage (kV) radiographs or megavoltage (MV) images with digital reconstructed radiographs (DRRs) from the planning CT. These two methods comprise the bulk of IGRT strategies currently employed circa 2013.This process is distinct from the use of imaging to delineate targets and organs in the planning process of radiation therapy. However, there is clearly a connection between the imaging processes as IGRT relies directly on the imaging modalities from planning as the reference coordinates for localizing the patient. The variety of medical imaging technologies used in planning includes x-ray computed tomography (CT), magnetic resonance imaging (MRI), and positron emission tomography (PET) among others. The precision of IGRT is significantly improved when N-localizer technology is used in conjunction with these medical imaging technologies. Through advancements in imaging technology, combined with a further understanding of human biology at the molecular level, the impact of IGRT on radiotherapy treatment continues to evolve.