• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Chapter 15 SPECIAL PROCEDURES AND TECHNIQUES IN
Chapter 15 SPECIAL PROCEDURES AND TECHNIQUES IN

... ● The requirements for positional and numerical accuracy in dose delivery are ±1 mm and ±5%, respectively. ● The dose in stereotactic irradiation may be delivered through a stereotactic implantation of radioactive sources (stereotactic brachytherapy) or, more commonly, with one or several external r ...
iconnect - Siemens India
iconnect - Siemens India

... Get the full picture The syngo.via 3D and advanced visualization solution helps to accelerate workflows across all modalities and is perfect for both day-to-day and more challenging cases. We have now introduced new applications:  syngo.CT Myocardial Perfusion: Analysis and visualization of the fu ...
Optimisation in general radiography (PDF Available)
Optimisation in general radiography (PDF Available)

... Radiography using film has been an established method for imaging the internal organs of the body for over 100 years. Surveys carried out during the 1980s identified a wide range in patient doses showing that there was scope for dosage reduction in many hospitals. This paper discusses factors that n ...
X-ray production
X-ray production

...  These systems use continuous electric power to produce the magnetic field, produce a significant amount of heat, and often require additional cooling subsystems.  The magnetic field of resistive systems ranges from 0.1 T to about 0.3 T.  An advantage of purely resistive system is the ability to ...
Performance Measurement Set Specifications
Performance Measurement Set Specifications

... director of quality improvement for the non-invasive laboratory: Diagnostic Error Rate Alternatively the number of accurate diagnoses can be reported over the total number of cases reviewed: Diagnostic Accuracy Rate Challenges to Implementation ...
bs radiology curriculum - Institute of Paramedical Sciences
bs radiology curriculum - Institute of Paramedical Sciences

... Following competencies will be expected from a student on completing four years degree course in Radiology. The student should be proficient to: ...
Image Acquisition and Processing Hardware
Image Acquisition and Processing Hardware

... processing of the input digital data. ...
Enhancing Vascular Imaging by OCT at the Charité Hospital
Enhancing Vascular Imaging by OCT at the Charité Hospital

... Clinical applications of OCT Professor Witzenbichler began using OCT as part of a clinical study of treatments for acute myocardial infarction, designed to assess the correct positioning (apposition) of self-expanding and conventional stents. OCT is considered uniquely powerful as a tool: To determ ...
Optical microscopy
Optical microscopy

... • CT scans use a series of X-ray beams • It creates cross-sectional images, e.g. of the brain and shows the structure of the brain, but not its function. • Digital geometry processing is used to generate a threedimensional image of the internals of an object from a large series of two-dimensional X- ...
Gallium isotopes in medicine Ga is a radioactive isotope that emits
Gallium isotopes in medicine Ga is a radioactive isotope that emits

... and an equal but opposite (positive) charge. [return] positron emission tomography (PET) scan – an imaging technique that is used to observe metabolic activity within the body. The system detects pairs of gamma rays emitted indirectly by a radioactive isotope used as a tracer, which emits positrons ...
Intelligent Multimedia Databases for Medicine
Intelligent Multimedia Databases for Medicine

... PACS replaces hard-copy based means of managing medical images, such as film archives It expands on the possibilities of such conventional systems by providing capabilities of off-site viewing and reporting (distance education, tele-diagnosis) Additionally, it enables practitioners at various physic ...
ambient
ambient

... around the current filaments and local reconnections during merging filaments in relativistic jets. • Broadband (not monoenergetic) jets sustain the stronger magnetic field over a longer region. • The magnetic fields created by Weibel instability generate highly inhomogeneous magnetic fields, which ...
BIRADS Atlas Preface - American College of Radiology
BIRADS Atlas Preface - American College of Radiology

... The Fifth Edition, like its predecessor, includes sections on ultrasound and magnetic resonance imaging (MRI) of the breast. As you will see, the number of actual cases has been increased significantly throughout all sections of the atlas. The new edition has a total of approximately 600 images. Als ...
Computer`s role in Medical - University of Wisconsin
Computer`s role in Medical - University of Wisconsin

... determine the due date. If one is having problems with blood circulation in a limb or heart, a Doppler ultrasound can check on the blood flow. Ultrasound has been a popular medical imaging technique for many years. ...
PDF of this page - The University of Kansas
PDF of this page - The University of Kansas

... part of the presentation of the Department of Anatomy and Cell Biology. Various types of X-rays and imaging studies including vascular studies, MRI, and CT demonstrate the necessity of a firm foundation in anatomy and illustrate how changes in anatomy form the foundation of disease processes. This b ...
Basic Principles of Computed Axial Tomography
Basic Principles of Computed Axial Tomography

... of the relative merits of these algorithms is outside the scope of this work. The method of reconstruction which is currently used in most CT devices is conceptually quite simple. Called either the "convolution" or the "filtered back projection" reconstruction method, 5-7 it can be illustrated as fo ...
0950-Horii-Practical-Guide-clinical-workflow
0950-Horii-Practical-Guide-clinical-workflow

... • There are vendor-based standards, but they are usually proprietary • There are standards (HDMI for video) that permit display on different devices, but not integration/interoperation ...
SPECT/CT Preparation
SPECT/CT Preparation

... SPECT/CT combines two imaging techniques – Nuclear Medicine SPECT which demonstrates function and CT (computed tomography) which demonstrates detailed anatomy. SPECT shows function at the cellular level within the body, and CT shows exactly where the abnormality is located in the body. Combining the ...
An Attempt to Establish National Dose Reference Levels for
An Attempt to Establish National Dose Reference Levels for

... used in medical field globally. In further developments, along with the development in computer technology and programming algorithms, in the 1970s, Sir Godfrey N. Hounsfield, a British engineer invented a computed tomography (CT) scanner to make a tomographic image of the human body interior transv ...
Positron Emission Tomography/Computed Tomography Findings in
Positron Emission Tomography/Computed Tomography Findings in

... but it also cannot be used for assessment of bone erosion and treatment monitoring (4). Tc-99 MDP scan is used for revealing early osteomyelitis. Ga-67 is useful for monitoring response to therapy (7). However, these conventional nuclear medicine studies lack anatomic detail and require long imaging ...
Nobel Prize for CT and MRI pioneers
Nobel Prize for CT and MRI pioneers

... equilibrium according to two time constants, T1 and T2. It is the differences in the T1 times and T2 times of the various tissues that account for tissue contrast from which MR images can be produced using three orthogonal magnetic field gradients that are applied to the patient during the imaging ...
ACR–SPR–STR Practice Parameter for the Performance of Pulmonary
ACR–SPR–STR Practice Parameter for the Performance of Pulmonary

... patients. Practice Parameters and Technical Standards are not inflexible rules or requirements of practice and are not intended, nor should they be used, to establish a legal standard of care1. For these reasons and those set forth below, the American College of Radiology and our collaborating medic ...
Digital Radiography Positioning Guide
Digital Radiography Positioning Guide

... Information and insights into radiography using your IDEXX Digital Imaging System ...
Appraisal of Radiation Dose Received in Abdominal Computed
Appraisal of Radiation Dose Received in Abdominal Computed

... Radiation Therapy from College of Medical radiological Science, Sudan University of Science and Technology in 2005, 2009 and 2013 respectively. He was professor (assistant) in College of Medical radiological Science, Sudan University of Science and Technology from September 2006 to March 2015. Form ...
4DCT And Respiratory Motion Management Strategies In Lung
4DCT And Respiratory Motion Management Strategies In Lung

... 1. Identify the tumour position in real time 2. Anticipate the tumour motion to allow for time delays in the response of the beam-positioning system 3. Reposition the beam 4. Adapt the dosimetry to allow for changing lung volume and critical structure locations during the breathing cycle. ...
< 1 ... 117 118 119 120 121 122 123 124 125 ... 173 >

Image-guided radiation therapy

Image-guided radiation therapy (IGRT) is the process of frequent two and three-dimensional imaging, during a course of radiation treatment, used to direct radiation therapy utilizing the imaging coordinates of the actual radiation treatment plan. The patient is localized in the treatment room in the same position as planned from the reference imaging dataset. An example of IGRT would include localization of a cone beam computed tomography (CBCT) dataset with the planning computed tomography (CT) dataset from planning. IGRT would also include matching planar kilovoltage (kV) radiographs or megavoltage (MV) images with digital reconstructed radiographs (DRRs) from the planning CT. These two methods comprise the bulk of IGRT strategies currently employed circa 2013.This process is distinct from the use of imaging to delineate targets and organs in the planning process of radiation therapy. However, there is clearly a connection between the imaging processes as IGRT relies directly on the imaging modalities from planning as the reference coordinates for localizing the patient. The variety of medical imaging technologies used in planning includes x-ray computed tomography (CT), magnetic resonance imaging (MRI), and positron emission tomography (PET) among others. The precision of IGRT is significantly improved when N-localizer technology is used in conjunction with these medical imaging technologies. Through advancements in imaging technology, combined with a further understanding of human biology at the molecular level, the impact of IGRT on radiotherapy treatment continues to evolve.