Focal Orbital Amyloidosis Presenting as Rectus Muscle
... and showed characteristic green birefringence when viewed under polarized light (Fig 1G). The specimen was decolorized after treatment with potassium permanganate. The diagnosis of amyloidosis (AA form) was made histopathologically. Rectal biopsy performed after surgery was negative for amyloid. No ...
... and showed characteristic green birefringence when viewed under polarized light (Fig 1G). The specimen was decolorized after treatment with potassium permanganate. The diagnosis of amyloidosis (AA form) was made histopathologically. Rectal biopsy performed after surgery was negative for amyloid. No ...
Lung Image Database Consortium: Developing a Resource for the
... (12,16,20,23–26), fuzzy clustering algorithms (13), spatial filtering (15), template matching (22), object-based deformation procedures (17), morphologic analysis (18), and model-based techniques (14,21). The computerized classification of lung nodules as cancerous or noncancerous has also received ...
... (12,16,20,23–26), fuzzy clustering algorithms (13), spatial filtering (15), template matching (22), object-based deformation procedures (17), morphologic analysis (18), and model-based techniques (14,21). The computerized classification of lung nodules as cancerous or noncancerous has also received ...
Non-Invasive ECG Mapping To Guide Catheter Ablation
... Since more than 100 years, 12-lead electrocardiography (ECG) is the standard-of-care tool, which involves measuring electrical potentials from limited sites on the body surface to diagnose cardiac disorder, its possible mechanism and the likely site of origin. Several decades of research has led to ...
... Since more than 100 years, 12-lead electrocardiography (ECG) is the standard-of-care tool, which involves measuring electrical potentials from limited sites on the body surface to diagnose cardiac disorder, its possible mechanism and the likely site of origin. Several decades of research has led to ...
salivary gland radio.. - 口腔病理科教學網
... Excellent for differentiating between solid & cystic masses Different echo signals are obtained from different tumors Identification of radiolucent stones Lithotripsy of salivary stones now possible Disadvantages The sound waves used are blocked by bone, so limiting the areas available for investiga ...
... Excellent for differentiating between solid & cystic masses Different echo signals are obtained from different tumors Identification of radiolucent stones Lithotripsy of salivary stones now possible Disadvantages The sound waves used are blocked by bone, so limiting the areas available for investiga ...
Efficacy of Feraheme as a Lymphatic Contrast Agent in Prostate
... It is hoped that the adaptability of this protocol will foster more widespread use of this agent in an attempt to further delineate its ability to define lymphatic metastatic disease. The imaging protocols utilized on these patients are available throughout the United States. It is hoped that the ab ...
... It is hoped that the adaptability of this protocol will foster more widespread use of this agent in an attempt to further delineate its ability to define lymphatic metastatic disease. The imaging protocols utilized on these patients are available throughout the United States. It is hoped that the ab ...
Evaluation of absorbed dose and image quality in mammography
... With a lot of help from my friends ...
... With a lot of help from my friends ...
C a t p h a n ® 500 and 600 M a n u a l
... numbers 4 and 5 will have better uniformity than outer slice numbers 1 and 8 because of the scanner x-ray beam geometry. However, if 1 and 8 or 4 and 5 are not similar, this may indicate a problem with the scanner. When assessing a scanner with a step and shoot mode, it is important to cover the ful ...
... numbers 4 and 5 will have better uniformity than outer slice numbers 1 and 8 because of the scanner x-ray beam geometry. However, if 1 and 8 or 4 and 5 are not similar, this may indicate a problem with the scanner. When assessing a scanner with a step and shoot mode, it is important to cover the ful ...
Creating in-vitro phantoms of blood vessels to support the testing
... Abstract: Ultrasound has proven to be a versatile technique, and its applications could be broadened by focussing on the visualization of perfusion throughout the microcirculatory system. This implies the use of high-frequency imaging (>15 MHz) which augments the spatial resolution needed to detect ...
... Abstract: Ultrasound has proven to be a versatile technique, and its applications could be broadened by focussing on the visualization of perfusion throughout the microcirculatory system. This implies the use of high-frequency imaging (>15 MHz) which augments the spatial resolution needed to detect ...
Diffusion Tensor Imaging: Concepts and Applications
... from its specific organization in bundles of more or less myelinated axonal fibers running in parallel, although the exact mechanism is still not completely understood (see below): diffusion in the direction of the fibers is faster than in the perpendicular direction. It quickly appeared that this f ...
... from its specific organization in bundles of more or less myelinated axonal fibers running in parallel, although the exact mechanism is still not completely understood (see below): diffusion in the direction of the fibers is faster than in the perpendicular direction. It quickly appeared that this f ...
Imaging Evaluation of Cutaneous Symptoms in the
... fashion through foramen rotundum and the cavernous sinus (green arrow) and continues inferiorly along V3 through foramen ovale (magenta arrow) into the masticator space. CT-guided fine needle aspiration revealed poorly-differentiated squamous cell carcinoma. However, a primary site was not identifie ...
... fashion through foramen rotundum and the cavernous sinus (green arrow) and continues inferiorly along V3 through foramen ovale (magenta arrow) into the masticator space. CT-guided fine needle aspiration revealed poorly-differentiated squamous cell carcinoma. However, a primary site was not identifie ...
Principles and clinical application of ultrasound - e
... which are called shear waves. In the case of transient elastography, a mechanical push is used for excitation application, which produces transient shear waves in the target tissue. This type of excitation application is classified as a dynamic elastography technique with an external source. In addi ...
... which are called shear waves. In the case of transient elastography, a mechanical push is used for excitation application, which produces transient shear waves in the target tissue. This type of excitation application is classified as a dynamic elastography technique with an external source. In addi ...
Get PDF - OSA Publishing
... light source behind the objects to provide you with a transmission imaging geometry. Glare suppression in principle is possible using time-of-flight methods with the help of fast imaging systems, such as those based on intensified charge-coupled device (ICCD) technology [13–15] or single-photon aval ...
... light source behind the objects to provide you with a transmission imaging geometry. Glare suppression in principle is possible using time-of-flight methods with the help of fast imaging systems, such as those based on intensified charge-coupled device (ICCD) technology [13–15] or single-photon aval ...
Positron Emission Tomography in Urology - EU-ACME
... converted into energy following Einstein’s formula E = mc2. It has been calculated that the energy present in this system is 1022 kilo-electron Volts (keV). However, in order to fulfill the law on conservation of momentum, this energy is released as 2 gamma-photons with energy of 511 keV which are e ...
... converted into energy following Einstein’s formula E = mc2. It has been calculated that the energy present in this system is 1022 kilo-electron Volts (keV). However, in order to fulfill the law on conservation of momentum, this energy is released as 2 gamma-photons with energy of 511 keV which are e ...
The Bioimpedance Technique in Respiratory
... [45]. On the other hand, direct airway measurements have been criticized for low patient tolerability [106]. In addition, datadriven methods may depend on radiopharmaceutical uptake, patient body habitus, or scanner geometry [29]. Further, there ...
... [45]. On the other hand, direct airway measurements have been criticized for low patient tolerability [106]. In addition, datadriven methods may depend on radiopharmaceutical uptake, patient body habitus, or scanner geometry [29]. Further, there ...
Radiological protection for medical exposure to ionizing radiation
... Gy) precisely delivered to target volumes in order to eradicate disease or to alleviate symptoms. Over 90% of total radiation treatments are conducted by teletherapy or brachytherapy, with radiopharmaceuticals being used in only 7% of treatments [1]. 1.4. Increases in the uses of medical radiation a ...
... Gy) precisely delivered to target volumes in order to eradicate disease or to alleviate symptoms. Over 90% of total radiation treatments are conducted by teletherapy or brachytherapy, with radiopharmaceuticals being used in only 7% of treatments [1]. 1.4. Increases in the uses of medical radiation a ...
ICD Registry™ v2.2 - Integrating the Healthcare Enterprise (IHE)
... Standardize report organization and representation of clinical information • Organize content that is familiar for clinicians • Looking to provide electronic equivalent of existing hardcopy reports Patient Care Use Case Report generated to document the imaging exam/procedure for consumption by CVIS ...
... Standardize report organization and representation of clinical information • Organize content that is familiar for clinicians • Looking to provide electronic equivalent of existing hardcopy reports Patient Care Use Case Report generated to document the imaging exam/procedure for consumption by CVIS ...
diagnostic imaging equipment industry
... After an introduction outlining the study, Chapter 1 presents the basic conditions of the industry, including product descriptions, supply and demand conditions, and the regulatory environment. Quality characteristics are found to be especially important in this market. Market structure is analyzed ...
... After an introduction outlining the study, Chapter 1 presents the basic conditions of the industry, including product descriptions, supply and demand conditions, and the regulatory environment. Quality characteristics are found to be especially important in this market. Market structure is analyzed ...
MAGNETIC RESONANCE IMAGING OF THE INTERNALLY
... complications. It is unique in its ability to demonstrate the nature and extent of injuries. Imaging can be accomplished in any plane without moving the patient and a wide variety of MRI pulse sequences can be performed to produce diagnostic quality images. These include spin echo, fast (turbo) spin ...
... complications. It is unique in its ability to demonstrate the nature and extent of injuries. Imaging can be accomplished in any plane without moving the patient and a wide variety of MRI pulse sequences can be performed to produce diagnostic quality images. These include spin echo, fast (turbo) spin ...
Optimal parameters for clinical implementation of breast cancer
... much noise for visualization of the clips. Similar findings were reported by Thomas et al.(3) In addition, our clinical experience has shown that rotations and translations can be difficult to distinguish using only two orthogonal planar images. Therefore volumetric images are desired for accurate p ...
... much noise for visualization of the clips. Similar findings were reported by Thomas et al.(3) In addition, our clinical experience has shown that rotations and translations can be difficult to distinguish using only two orthogonal planar images. Therefore volumetric images are desired for accurate p ...
Comparing the performance of visual estimation and standard
... of the lesion. When it was difficult to discern the range of the lesion with PET/CT, we used contrastenhanced CT or magnetic resonance imaging (MRI) to set the region of interest on the very limit of the inside of the lesion, so as to not extend over the border of the lesion and not pick up uptake f ...
... of the lesion. When it was difficult to discern the range of the lesion with PET/CT, we used contrastenhanced CT or magnetic resonance imaging (MRI) to set the region of interest on the very limit of the inside of the lesion, so as to not extend over the border of the lesion and not pick up uptake f ...
Management of the Incidentally Discovered Adrenal Mass
... CT. With current collimation, masses between 3 and 9 mm are being discovered on a routine basis, which emphasizes that this issue will only increase in the future. As previously mentioned, myelolipoma, cysts and hemorrhages have distinct features on imaging that are well-documented in the literature ...
... CT. With current collimation, masses between 3 and 9 mm are being discovered on a routine basis, which emphasizes that this issue will only increase in the future. As previously mentioned, myelolipoma, cysts and hemorrhages have distinct features on imaging that are well-documented in the literature ...
Package Insert - Zevacor Molecular
... ranging from 19 MBq-148 MBq (0.5 mCi-4 mCi) were used. Sodium Fluoride F 18 Injection was shown to localize to areas of bone turnover including rapidly growing epiphyses in developing long bones. Children are more sensitive to radiation and may be at higher risk of cancer from Sodium Fluoride F 18 I ...
... ranging from 19 MBq-148 MBq (0.5 mCi-4 mCi) were used. Sodium Fluoride F 18 Injection was shown to localize to areas of bone turnover including rapidly growing epiphyses in developing long bones. Children are more sensitive to radiation and may be at higher risk of cancer from Sodium Fluoride F 18 I ...
- Braincon
... Abstract Nowadays, conventional or digitalized teleradiography remains the most commonly used tool for the study of the sagittal balance, sometimes with secondary digitalization. The irradiation given by this technique is important and the photographic results are often poor. Some radiographic table ...
... Abstract Nowadays, conventional or digitalized teleradiography remains the most commonly used tool for the study of the sagittal balance, sometimes with secondary digitalization. The irradiation given by this technique is important and the photographic results are often poor. Some radiographic table ...
Reporting Standards for Percutaneous Thermal
... the ipsilateral or contralateral kidney must be noted. To enable determination of the effect of RF ablation on long-term renal function, serum creatinine levels and glomerular filtration rate (measured directly or estimated according to the Cockcroft and Gault equation) must be reported at baseline ...
... the ipsilateral or contralateral kidney must be noted. To enable determination of the effect of RF ablation on long-term renal function, serum creatinine levels and glomerular filtration rate (measured directly or estimated according to the Cockcroft and Gault equation) must be reported at baseline ...
Medical imaging
Medical imaging is the technique and process of creating visual representations of the interior of a body for clinical analysis and medical intervention. Medical imaging seeks to reveal internal structures hidden by the skin and bones, as well as to diagnose and treat disease. Medical imaging also establishes a database of normal anatomy and physiology to make it possible to identify abnormalities. Although imaging of removed organs and tissues can be performed for medical reasons, such procedures are usually considered part of pathology instead of medical imaging.As a discipline and in its widest sense, it is part of biological imaging and incorporates radiology which uses the imaging technologies of X-ray radiography, magnetic resonance imaging, medical ultrasonography or ultrasound, endoscopy, elastography, tactile imaging, thermography, medical photography and nuclear medicine functional imaging techniques as positron emission tomography.Measurement and recording techniques which are not primarily designed to produce images, such as electroencephalography (EEG), magnetoencephalography (MEG), electrocardiography (ECG), and others represent other technologies which produce data susceptible to representation as a parameter graph vs. time or maps which contain information about the measurement locations. In a limited comparison these technologies can be considered as forms of medical imaging in another discipline.Up until 2010, 5 billion medical imaging studies had been conducted worldwide. Radiation exposure from medical imaging in 2006 made up about 50% of total ionizing radiation exposure in the United States.In the clinical context, ""invisible light"" medical imaging is generally equated to radiology or ""clinical imaging"" and the medical practitioner responsible for interpreting (and sometimes acquiring) the images is a radiologist. ""Visible light"" medical imaging involves digital video or still pictures that can be seen without special equipment. Dermatology and wound care are two modalities that use visible light imagery. Diagnostic radiography designates the technical aspects of medical imaging and in particular the acquisition of medical images. The radiographer or radiologic technologist is usually responsible for acquiring medical images of diagnostic quality, although some radiological interventions are performed by radiologists.As a field of scientific investigation, medical imaging constitutes a sub-discipline of biomedical engineering, medical physics or medicine depending on the context: Research and development in the area of instrumentation, image acquisition (e.g. radiography), modeling and quantification are usually the preserve of biomedical engineering, medical physics, and computer science; Research into the application and interpretation of medical images is usually the preserve of radiology and the medical sub-discipline relevant to medical condition or area of medical science (neuroscience, cardiology, psychiatry, psychology, etc.) under investigation. Many of the techniques developed for medical imaging also have scientific and industrial applications.Medical imaging is often perceived to designate the set of techniques that noninvasively produce images of the internal aspect of the body. In this restricted sense, medical imaging can be seen as the solution of mathematical inverse problems. This means that cause (the properties of living tissue) is inferred from effect (the observed signal). In the case of medical ultrasonography, the probe consists of ultrasonic pressure waves and echoes that go inside the tissue to show the internal structure. In the case of projectional radiography, the probe uses X-ray radiation, which is absorbed at different rates by different tissue types such as bone, muscle and fat.The term noninvasive is used to denote a procedure where no instrument is introduced into a patient's body which is the case for most imaging techniques used.