• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Endoscopic ultrasonography identifies patients unlikely to be cured by
Endoscopic ultrasonography identifies patients unlikely to be cured by

... next generation of scanners, which can acquire up to 32 slices per second with even faster scan times. The impact of these new scanners on diagnostic accuracy will need to be carefully evaluated. Several studies have compared the accuracy of angiography and EUS for determining vascular invasion.17,1 ...
Inclusion of the dose from kilovoltage cone beam CT in the radiation
Inclusion of the dose from kilovoltage cone beam CT in the radiation

... We have modeled the kV CBCT beam from a Varian OBI system on a Trilogy linear accelerator 共Varian Medical Systems, Palo Alto, CA兲 in the Philips PINNACLE treatment planning system v8.0 共Philips Medical Systems, Milpitas, CA兲. The OBI system has been extensively described elsewhere.1,10 In brief, the ...
Radiation Protection – Chapter 23, Bushberg
Radiation Protection – Chapter 23, Bushberg

... is obsolete and out of print. Bushberg notes that it is badly out of date. NCRP 147 replaced NCRP 49 in 2005. It should be used for all shielding calculations. NCRP 147 uses a different methodology to calculate the shielding values and uses much more realistic values for occupancy, tube kVps, weekly ...
RADIATION PROTECTION IN PEDIATRIC RADIOGRAPHY
RADIATION PROTECTION IN PEDIATRIC RADIOGRAPHY

... radiologists and radiographers should work together to provide a child friendly environment during imaging, to minimize the stress for the patient and parents, and to facilitate the child’s cooperation. The maximum information possible must be gained from the radiographic procedure. Considerable ski ...
2008 January DAI News - Carl E Ravin Advanced Imaging
2008 January DAI News - Carl E Ravin Advanced Imaging

... to develop a clinical imaging device for detection of iron overload in the liver. Recent simulation experiments have shown that NSECT has strong potential in detecting isolated regions of elevated iron concentration in a human liver through tomographic scanning with clinically acceptable dose levels ...
Lecture Outline 16: Special Topics in Protection
Lecture Outline 16: Special Topics in Protection

... patient scanning. The x-ray tube within the gantry revolves around the patient at the same time that the table is moving into the bore of the gantry. ...
Advances in Treatment Planning Techniques and Technologies for Esophagus Cancer
Advances in Treatment Planning Techniques and Technologies for Esophagus Cancer

... • Suggest Left Lateral or LPO with PA ...
6668 Form Completion Guidelines
6668 Form Completion Guidelines

... to registration to determine and confirm study eligibility. It includes general demographic characteristics (including age, gender, and race), inclusion/exclusion criteria checks, and receipt of written informed consent. At the time of enrollment, the participant is to review, sign and date the cons ...
Image Guided Radiation Therapy: A Refresher
Image Guided Radiation Therapy: A Refresher

... Princess Margaret Hospital/Ontario Cancer Institute Professor Departments of Radiation Oncology and Medical Biophysics University of Toronto ...
Multimodality image integration for radiotherapy - DIE
Multimodality image integration for radiotherapy - DIE

... allows increases of 15 to 25% over traditional standard total doses 2. The aim of 3D planning is to adjust radiation beams to the shape of the volume to be treated, minimizing radiation to neighboring regions. Beam intensity modulation consists of manipulating the radiation beam, so that each beam r ...
6,7,8,9,10
6,7,8,9,10

... anal sphincter and puborectalis muscles in normal children. The muscle thickness was graded by keeping age adjusted range of thickness for external anal sphincter and puborectalis muscles and thereby MRI scoring was categorized as good, moderate/ fair and poor/ severe hypoplasia. The Kelly’s score i ...
ACR–SPR–STR Practice Parameter for the Performance of Pulmonary
ACR–SPR–STR Practice Parameter for the Performance of Pulmonary

... the patient, limitations of available resources, or advances in knowledge or technology subsequent to publication of this document. However, a practitioner who employs an approach substantially different from the guidance in this document is advised to document in the patient record information suff ...
Exposure to Diagnostic Ionizing Radiation in Sports
Exposure to Diagnostic Ionizing Radiation in Sports

... in the trunk, and, therefore, investigations (radiography and CT) in the trunk region carry a much greater effective dose than investigations of the extremities. It should be noted that effective dose is an estimate of the whole body dose that would be required to produce the same detriment as the p ...
Digital chest radiography
Digital chest radiography

... evaluated radiograph had excessive collimation and should be reduced as this digital chest radiograph is one of the most common examinations with 641,561 examinations performed on Danish departments of medical imaging in 2013 (2). Pervious studies evaluating lumbar spine radiographs found likewise l ...
organ and effective doses from a multidetector computed
organ and effective doses from a multidetector computed

... Abstract: The growth of Multidetector Computed Tomography (MDCT) associated with the large number of images per examination offers many clinical benefits. It is easy to use for radiologist and physician, and these reasons are the cause of increasing exposure for populations rapidly. Organ and effect ...
Safety of the Gadolinium-Based Contrast Agents for Magnetic
Safety of the Gadolinium-Based Contrast Agents for Magnetic

... Abstract: The established class of intravenous contrast media for magnetic resonance imaging is the gadolinium chelates, more generally referred to as the gadolinium-based contrast agents (GBCAs). These can be differentiated on the basis of stability in vivo, with safety and tolerability of the GBCA ...
CT Simulation Refresher Course Sasa Mutic, MS
CT Simulation Refresher Course Sasa Mutic, MS

... conventional simulation process is that very little anatomy, other than bony anatomy, is available for design of treatment portals. CT images provide information not only about target volumes but about critical (normal) organs as well. Using CT images for radiation therapy treatment planning has ena ...
Whats New in DICOM
Whats New in DICOM

...  Extensive detail on beam setting options  Enhancements to patient position and fixation devices that will be ...
Medicinska fizika: znanost in poklic
Medicinska fizika: znanost in poklic

... Clinical x-ray beams  Clinical x-ray beams typically range in energy between 10 kVp and 50 MV and are produced in x-ray targets when electrons with kinetic energies between 10 keV and ...
Good Afternoon I am Bulent Aydogan and I will be Good Afternoon I
Good Afternoon I am Bulent Aydogan and I will be Good Afternoon I

... We are used to see evaluate plan using absorbed dose in tissue represented by isodose line.s As shown in this Stocholm system based treatment isodose lines are replaced by by mg-h lines ...
Document
Document

... not reach bone (soft stop), the obstruction was classified as canalicular. Informed consent was obtained from all patients for further imaging using CBCT. Subjects presenting with iodine or contrast material solution allergies were excluded. The ophthalmologist referred patients for DCG using 2 diff ...
Applied Physics Radiation Oncology
Applied Physics Radiation Oncology

... geometry, distances (SSD, SDD, etc.), beam divergence, and field size. A simulator produces high-quality images of the treatment field. During simulation, the patient is placed in as comfortable a position as is consistent with good beam placement. Accurate, reproducible positioning is critical sinc ...
May 15, 2015 Dear Sir or Madam, Thank you for the opportunity to
May 15, 2015 Dear Sir or Madam, Thank you for the opportunity to

... We believe that there are multiple resources to aid in biomarker development, validation and qualification that can be utilized across appropriate stakeholders. There is certainly value in bringing together a variety of efforts that are ongoing to increase awareness of scientific advancements and pr ...
Contrast Optimization in Low Radiation Dose Imaging
Contrast Optimization in Low Radiation Dose Imaging

... ever, it is important to note that small reductions in kV have a more substantial effect on radiation dose reduction.5,6 Moreover, for iodinated contrast-enhanced exams, lower kVp values result not only in lower radiation dose exposure, but also higher contrast enhancement, especially when employed ...
multiplan" treatment planning system
multiplan" treatment planning system

... Lung Optimized Treatment – Makes non-invasive lung treatments an option for all lung SBRT patients and offers the optimal accuracy and steep dose fall off required to treat tumors anywhere in the lung, even those close to critical structures. Simulation and comparison workflows, combined with unique ...
< 1 ... 34 35 36 37 38 39 40 41 42 ... 67 >

Neutron capture therapy of cancer



Neutron capture therapy (NCT) is a noninvasive therapeutic modality for treating locally invasive malignant tumors such as primary brain tumors and recurrent head and neck cancer. It is a two step procedure: first, the patient is injected with a tumor localizing drug containing a non-radioactive isotope that has a high propensity or cross section (σ) to capture slow neutrons. The cross section of the capture agent is many times greater than that of the other elements present in tissues such as hydrogen, oxygen, and nitrogen. In the second step, the patient is radiated with epithermal neutrons, which after losing energy as they penetrate tissue, are absorbed by the capture agent which subsequently emits high-energy charged particles, thereby resulting in a biologically destructive nuclear reaction (Fig.1).All of the clinical experience to date with NCT is with the non-radioactive isotope boron-10, and this is known as boron neutron capture therapy (BNCT). At this time, the use of other non-radioactive isotopes, such as gadolinium, has been limited, and to date, it has not been used clinically. BNCT has been evaluated clinically as an alternative to conventional radiation therapy for the treatment of malignant brain tumors (gliomas), and more recently, recurrent, locally advanced head and neck cancer.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report