• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Radiation Protection and Dose Monitoring in Medical
Radiation Protection and Dose Monitoring in Medical

... are collaborating to achieve this worthy goal. Recording this information will not only provide a dose profile for a patient or a practice over time, but will also increase our ability to monitor and adhere to radiation protection principles such as optimization. Table 2 provides a list of potential ...
ICRP
ICRP

... Images of the highest quality are not essential for all diagnostic tasks, but rather the level of quality (e.g., low noise, medium or low dose) is dependent on the diagnostic task. Objective measures such as image noise or contrast-to-noise ratio may not completely capture all of the features releva ...
Is nuclear imaging a viable alternative technique to assess
Is nuclear imaging a viable alternative technique to assess

... (TDI) and myocardial strain-rate imaging are not ready for routine clinical practice to assess LV dyssynchrony.15 The PROSPECT study suggests that there is a need for better standardization and refinements of the echocardiographic screening tools currently used for the evaluation of LV dyssynchrony. ...
ESCH1317_Sarabjeet Singh
ESCH1317_Sarabjeet Singh

... and gaps in knowledge between scanning parameters and their effect on image quality. Our proposal will create web based, user-friendly interactive educational modules for protocol based CT radiation dose optimization that will educate the radiology community about the need and ways for clinical indi ...
Treatment of Neck Lines and Forehead Rhytids
Treatment of Neck Lines and Forehead Rhytids

... d ¼ ð3ma ½ma þ ms ð1  gÞÞ1=2 The optical window from 1.2 to 1.8 mm appears to be well suited for nonablative remodeling as penetration depth within this range is limited to the upper dermis.9–12 Table 1 displays the absorption and reduced scattering coefficients of human skin in this specific wind ...
Image Quality and Dose Comparison between
Image Quality and Dose Comparison between

... • Image quality with the spiral CT was superior for all imaging parameters, even at lower doses • While our currently employed spiral CT protocol offers superior image quality, dose is also greater ...
pet center of excellence newsletter Imaging Evaluation of Prostate Cancer with FDG-PET/CT
pet center of excellence newsletter Imaging Evaluation of Prostate Cancer with FDG-PET/CT

... The level and extent of FDG accumulation in metastatic lesions may provide information on prognosis. An increase of over 33% in the average maximum SUV measurement from up to five lesions, or the appearance of new lesions, was reported to be able to categorize castrate-sensitive metastatic prostate ...
The 20th Anniversary of the passage of the 1992 Mammography
The 20th Anniversary of the passage of the 1992 Mammography

... Radiology began its voluntary accreditation program. This action occurred at a time when mammography screening was becoming widely adopted, yet image quality, equipment, and radiation dose for the procedure varied considerably. Despite the ACR’s efforts, by 1992, only about 7,200 facilities out of a ...
Use of the Disease Ontology to Screen Genomic
Use of the Disease Ontology to Screen Genomic

... For both research and clinical WGS/WES results, the scientific community is in agreement that returning all results is not feasible as it is laborious and time-consuming. The types of results from research studies to consider for reporting in particular remains a matter of debate.[6, 7] When returni ...
Full Article (PDF file) - Journal of Gastrointestinal and
Full Article (PDF file) - Journal of Gastrointestinal and

... growth factor receptor. Many tumors previously diagnosed as leiomyomas, leiomyoblastomas, or leiomyosarcomas have been found to be positive for CD117 and are now considered GISTs. This includes tumors involving most sites in the gastrointestinal tract except the esophagus, where true leiomyomas are ...
2013 CuRe Preclerkship Presentation Jeffrey Mottola, M.D.
2013 CuRe Preclerkship Presentation Jeffrey Mottola, M.D.

... knowledge and interpretation skills to practice safely and effectively during clinical rotations • To demonstrate familiarity with: • Anatomy and physiology pertaining to radiology • Imaging physics and radiation protection • Radiology requisition and DI expectations • The characteristics of Imaging ...
High Resolution T2-Weighted Dixon Based Whole
High Resolution T2-Weighted Dixon Based Whole

... in rib cage that could not be detected with WB-MRI. This situation is consistent with the literature and believed to be caused by respiratory movements that would result in motion artifacts in MR images (10,14). This shortcoming of some MR sequences including T2WmD technique could probably be at lea ...
Role of 18F-fluorodeoxyglucose positron emission tomography
Role of 18F-fluorodeoxyglucose positron emission tomography

... covered that 18F-FDG PET or 18F-FDG PET/CT scans were positive in 4 of 16 patients with stage I disease. These findings suggest that 18F-FDG PET and 18F-FDG PET/CT are better than CT alone at detecting lesions in patients with stage I disease and the majority of patients with early stage CTCL seem t ...
Management of renal colic in the emergency department  E
Management of renal colic in the emergency department E

... treatment of renal colic, produced by the American Urological Association in 1997. Unfortunately the guideline concerns almost exclusively the indications and options for surgical management of renal calculi, which is not the major issue in an emergency department setting. In this context screening ...
Radiation Safety for the Cardiac Sonographer
Radiation Safety for the Cardiac Sonographer

... the source (increasing distance exponentially reduces exposure) and using shielding. From the Nuclear Regulatory Commission.12 for prolonged periods of time. Because the volume of patients receiving radioisotopes for nuclear scans shortly preceding the performance of TTE has increased, this exposure ...
The role of positron emission tomography in the management of non
The role of positron emission tomography in the management of non

... espite many advances in the diagnosis, staging and treatment of non–small cell lung cancer (NSCLC), the overall 5-year survival rate of patients with resectable NSCLC is less than 50%.1 This suboptimal survival rate is likely due to many factors, including the aggressiveness of the specific phenotyp ...
Radiologic Technology (W170210) - Florida Department Of Education
Radiologic Technology (W170210) - Florida Department Of Education

... 06.07 Explain how the radiographer determines that an adequate level of penetration has been applied to produce an acceptable image. 06.08 Summarize the importance of proper positioning. 06.09 Discuss the impact of patient preparation on the resulting radiographic image. 06.10 Analyze images to dete ...
Radiologic Technology (W170210) - Florida Department Of Education
Radiologic Technology (W170210) - Florida Department Of Education

... 06.07 Explain how the radiographer determines that an adequate level of penetration has been applied to produce an acceptable image. 06.08 Summarize the importance of proper positioning. 06.09 Discuss the impact of patient preparation on the resulting radiographic image. 06.10 Analyze images to dete ...
Thallous Chloride TI 201 Injection
Thallous Chloride TI 201 Injection

... maximum stress which is sustained for approximately 30 seconds after injection. Begin imaging within ten minutes after administration to obtain maximum target-to-background ratios. Within two hours after the completion of the stress testing the target-tobackground ratios may decrease in lesions that ...
M.Sc. Medical Physics Regulations and Syllabus from 2008
M.Sc. Medical Physics Regulations and Syllabus from 2008

... (d) At the end of the course the student must have an in depth knowledge in the field of Medical Physics. (e) Have an understanding about the radiation applications in diagnosis and treatment and its impact on health care and health care delivery. 3. MINIMUM QUALIFICATION FOR ADMISSION :The candidat ...
Guidelines for 18 F-FDG PET and PET-CT imaging in
Guidelines for 18 F-FDG PET and PET-CT imaging in

... Patient preparation A thorough explanation of the scan should be given to the patient and his/her parents or carers by the technologist or physician (including hydration, time/ duration of scanning, and details of the procedure itself). Information should be given both verbally and in writing to ens ...
Optimization of pulsed fluoroscopy in pediatric
Optimization of pulsed fluoroscopy in pediatric

... fluoroscopic image quality obtained sufficient for diagnostic purposes. Hence, the production of spot images (IQX) becomes unnecessary to a great extent. A very favorable effect seen in examinations is the fact that, in 50% of examinations, a normal, acceptable image is already obtained with the fir ...
European Higher Education Area Level 6 Benchmarking
European Higher Education Area Level 6 Benchmarking

... 3 http://www.estro.org/binaries/content/assets/estro/school/europeancurricula/recommended_core_curriculum-radiationtherapists---3rd-edition-2011.pdf ...
Attenuation correction of myocardial perfusion SPET in patients of
Attenuation correction of myocardial perfusion SPET in patients of

... patients who are obese and is not performed on patients with normal BMI, as was the case in our department. The remit of this study was not to evaluate the diagnostic accuracy of attenuation correction as this has been extensively covered in the literature, but to determine whether there is a differ ...
Radiation - inayacollegedrmohammedemam
Radiation - inayacollegedrmohammedemam

... • Uranium have 92P and 146N. Why is that??? Nucleus is held together by a strong nuclear force; All these nucleons are held together by this force (came from neutrons) which hold the nucleus together. ...
< 1 ... 28 29 30 31 32 33 34 35 36 ... 67 >

Neutron capture therapy of cancer



Neutron capture therapy (NCT) is a noninvasive therapeutic modality for treating locally invasive malignant tumors such as primary brain tumors and recurrent head and neck cancer. It is a two step procedure: first, the patient is injected with a tumor localizing drug containing a non-radioactive isotope that has a high propensity or cross section (σ) to capture slow neutrons. The cross section of the capture agent is many times greater than that of the other elements present in tissues such as hydrogen, oxygen, and nitrogen. In the second step, the patient is radiated with epithermal neutrons, which after losing energy as they penetrate tissue, are absorbed by the capture agent which subsequently emits high-energy charged particles, thereby resulting in a biologically destructive nuclear reaction (Fig.1).All of the clinical experience to date with NCT is with the non-radioactive isotope boron-10, and this is known as boron neutron capture therapy (BNCT). At this time, the use of other non-radioactive isotopes, such as gadolinium, has been limited, and to date, it has not been used clinically. BNCT has been evaluated clinically as an alternative to conventional radiation therapy for the treatment of malignant brain tumors (gliomas), and more recently, recurrent, locally advanced head and neck cancer.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report