View the Semester Catalog (DOCX 15.6KB)
... The Electrical Technology program prepares students for ever increasing career opportunities within the electrical field. From the designing of construction projects in residential, commercial, and industrial areas to the completion of these projects, students experience all phases of an electrical ...
... The Electrical Technology program prepares students for ever increasing career opportunities within the electrical field. From the designing of construction projects in residential, commercial, and industrial areas to the completion of these projects, students experience all phases of an electrical ...
Local Technical - Florida Building Code
... Surge-Protective Devices (SPDs) shall be installed on all service equipment. Where used at a point on a circuit, a surge-protective device shall be connected to each ungrounded conductor. A single installation of such surge-protective devices shall be permitted to protect a number of interconnected ...
... Surge-Protective Devices (SPDs) shall be installed on all service equipment. Where used at a point on a circuit, a surge-protective device shall be connected to each ungrounded conductor. A single installation of such surge-protective devices shall be permitted to protect a number of interconnected ...
4 Electricity - Home Distribution
... In parallel circuits, the total current flowing in the circuit is the sum of the individual currents through the devices. Too many appliance operating on a single power circuit will produce a large current. The conducting wires get hot and melt their insulation, potentially causing a fire! ...
... In parallel circuits, the total current flowing in the circuit is the sum of the individual currents through the devices. Too many appliance operating on a single power circuit will produce a large current. The conducting wires get hot and melt their insulation, potentially causing a fire! ...
Electrical Safety
... Cut voltage and/or remove victim from contact as quickly as possible--but without endangering your own safety. Use a length of dry wood, rope, blanket, etc. , to pry or pull the victim loose. Don't waste valuable time looking for the power switch. The resistance of the victim's contact decreases wit ...
... Cut voltage and/or remove victim from contact as quickly as possible--but without endangering your own safety. Use a length of dry wood, rope, blanket, etc. , to pry or pull the victim loose. Don't waste valuable time looking for the power switch. The resistance of the victim's contact decreases wit ...
Maintenance and Testing for the Healthcare Industry — Isolated
... systems has resulted in specific requirements in NFPA 70, National Electrical Code (NEC), (Section 517.160) and NFPA 99, Standard for Healthcare Facilities, (Section 4). Specific to the NEC, Article 517-20(a) states that “(a)ll receptacles and fixed equipment within the area of the wet location shal ...
... systems has resulted in specific requirements in NFPA 70, National Electrical Code (NEC), (Section 517.160) and NFPA 99, Standard for Healthcare Facilities, (Section 4). Specific to the NEC, Article 517-20(a) states that “(a)ll receptacles and fixed equipment within the area of the wet location shal ...
Electrical Circuits
... Load – any element or group of elements in a circuit that dissipates energy EMF – Electromotive force → the energy per unit charge supplied by a source of electric current → A source of electrical energy → A “charge pump” → Examples are batteries and generators ...
... Load – any element or group of elements in a circuit that dissipates energy EMF – Electromotive force → the energy per unit charge supplied by a source of electric current → A source of electrical energy → A “charge pump” → Examples are batteries and generators ...
DB101 THRU DB107 FEATURES
... contained are intended to provide a product description only. "Typical" parameters which may be included on RECTRON data sheets and/ or specifications can and do vary in different applications and actual performance may vary over time. Rectron Inc does not assume any liability arising out of the app ...
... contained are intended to provide a product description only. "Typical" parameters which may be included on RECTRON data sheets and/ or specifications can and do vary in different applications and actual performance may vary over time. Rectron Inc does not assume any liability arising out of the app ...
DB101 THRU DB107
... contained are intended to provide a product description only. "Typical" parameters which may be included on RECTRON data sheets and/ or specifications can and do vary in different applications and actual performance may vary over time. Rectron Inc does not assume any liability arising out of the app ...
... contained are intended to provide a product description only. "Typical" parameters which may be included on RECTRON data sheets and/ or specifications can and do vary in different applications and actual performance may vary over time. Rectron Inc does not assume any liability arising out of the app ...
2002 NEC Code Changes
... requirements of Chapters 1 through 7 except as specifically referenced in Chapter 8 ...
... requirements of Chapters 1 through 7 except as specifically referenced in Chapter 8 ...
Chapter 37: Meter Usage and Circuit Diagnosis
... ► The DVOM can read a wide range of scales depending what position is selected. ► The DVOM can read from low to high values. ► The DVOM in auto range will select the best value for the range being measured. ► The min/max setting gives the technician the ability to measure circuits that are only on m ...
... ► The DVOM can read a wide range of scales depending what position is selected. ► The DVOM can read from low to high values. ► The DVOM in auto range will select the best value for the range being measured. ► The min/max setting gives the technician the ability to measure circuits that are only on m ...
COMBOLIGHT Remodel Recessed Trimless - 12V AR70 - 3 Light
... clean edge. Can accommodate various ceiling thickness. B.... System Protection: Thermal protection provided to guard against overheating and misuse of insulation over and around fixture. Vent holes in housing provide cooler operation. C.... Junction Box Junction Box is UL listed for through branch w ...
... clean edge. Can accommodate various ceiling thickness. B.... System Protection: Thermal protection provided to guard against overheating and misuse of insulation over and around fixture. Vent holes in housing provide cooler operation. C.... Junction Box Junction Box is UL listed for through branch w ...
AL XHHW - Southwire
... 60°C - When terminated to equipment for circuits rated 100 amperes or less or marked for 14 through 1 AWG conductors. 75°C - When terminated to equipment for circuits rated over 100 amperes or marked for conductors larger than 1 AWG. 90°C - THWN-2 wet or dry locations. For ampacity derating purposes ...
... 60°C - When terminated to equipment for circuits rated 100 amperes or less or marked for 14 through 1 AWG conductors. 75°C - When terminated to equipment for circuits rated over 100 amperes or marked for conductors larger than 1 AWG. 90°C - THWN-2 wet or dry locations. For ampacity derating purposes ...
COMBOLIGHT Remodel Recessed Trimless - 12V AR70 - 4 Light
... clean edge. Can accommodate various ceiling thickness. B.... System Protection: Thermal protection provided to guard against overheating and misuse of insulation over and around fixture. Vent holes in housing provide cooler operation. C.... Junction Box Junction Box is UL listed for through branch w ...
... clean edge. Can accommodate various ceiling thickness. B.... System Protection: Thermal protection provided to guard against overheating and misuse of insulation over and around fixture. Vent holes in housing provide cooler operation. C.... Junction Box Junction Box is UL listed for through branch w ...
COMBOLIGHT Remodel Recessed Trimless - 12V AR70 - 6 Light
... clean edge. Can accommodate various ceiling thickness. B.... System Protection: Thermal protection provided to guard against overheating and misuse of insulation over and around fixture. Vent holes in housing provide cooler operation. C.... Junction Box Junction Box is UL listed for through branch w ...
... clean edge. Can accommodate various ceiling thickness. B.... System Protection: Thermal protection provided to guard against overheating and misuse of insulation over and around fixture. Vent holes in housing provide cooler operation. C.... Junction Box Junction Box is UL listed for through branch w ...
S1700
... maintained and operationally tested in accordance with their installation instructions at the time of installation and at least twice a year or more often and in accordance with local, state and federal codes, regulations and laws. Specification, application, installation, operation, maintenance and ...
... maintained and operationally tested in accordance with their installation instructions at the time of installation and at least twice a year or more often and in accordance with local, state and federal codes, regulations and laws. Specification, application, installation, operation, maintenance and ...