• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Power Supply Safety Standards, Agencies and Marks
Power Supply Safety Standards, Agencies and Marks

... parts and the earth termination must not exceed 0.1 Ω, which is tested by a current 1.5 times the current capacity of any hazardous voltage circuit at the point where failure of basic insulation would make the earthed part live. Test voltage maximum is 12 V. Test current may be ac or dc but must not ...
CA320004EN
CA320004EN

... tamperproof and scratch-resistant protection. A six foot fiber optic cable connects the sensor to the display, thereby eliminating any electrical or metallic connection between the primary side and the secondary side of the transformer. A six foot low voltage cable from the display attaches to the s ...
Wiring - GTU e
Wiring - GTU e

... installations. The cleats are made in pairs having bottom and top halves. The bottom half is grooved to receive the wire and the top half is for cable grip. Initially the bottom and top cleats are fixed on the wall loosely according to the layout. Then the cable is drawn, tensioned and the cleats a ...
MQ1 System Number: 935
MQ1 System Number: 935

... dangerous when grounded, particularly above 300 volts—the majority of systems now being installed in the U.S. Recent fires have also shown that grounding of systems has created critical blindspots in ground-fault detection systems allowing grounded conductor faults to persist undetected setting up t ...
Document
Document

... that makes up a complete electrical circuit. ...
Duralum-metric 022815.indd
Duralum-metric 022815.indd

“TC” and “P” Edison Base Plug Fuses
“TC” and “P” Edison Base Plug Fuses

... CSA Certified (Class 1423-01, File # 53787) Benefits: • “D” rating for Canadian applications. • Heavy Duty TC fuses are industrial strength products, featuring Bussmann’s exclusive Dual-Element construction. • This spring loaded design provides superior short-circuit and overload protection. • The T ...
Electrical Engineering Student Outcomes: (a) An ability to apply
Electrical Engineering Student Outcomes: (a) An ability to apply

... (a) An ability to apply knowledge of mathematics, science, and engineering. (b) An ability to design and conduct experiments, as well as to analyze and interpret data. (c) An ability to design a system, component, or process to meet desired needs within realistic constraints such as economic, enviro ...
Electrical Safety
Electrical Safety

Constructing circuit diagrams with pst-circ
Constructing circuit diagrams with pst-circ

Electrical Fundamentals
Electrical Fundamentals

... • Semiconductors—materials that conduct electricity more easily than insulators but not as well as conductors – Used in transistors and microchips – Atoms with four valence ring electrons • Can be used as a switch ...
Slash Rated Devices 2
Slash Rated Devices 2

... two values and the voltage between any two conductors does not exceed the larger of the circuit breaker’s two values. Slash-rated devices can not be used on corner-grounded delta systems whenever the voltage to ground exceeds the smaller of the two ratings. Where slash-rated devices will not meet th ...
06_lecture_ppt
06_lecture_ppt

... – Overall resistance drops as more elements are added – Total circuit current increases as more elements are added ...
The 2002 National Electric Code (NEC)
The 2002 National Electric Code (NEC)

... required or permitted by the code shall only be acceptable if approved. This means it must be approved by the local authority having jurisdiction. (AHJ) 110.3 (B) Installation and Use. This section requires that equipment be installed and used in accordance with its installation instructions. All th ...
Electricity and Magnetism
Electricity and Magnetism

... which electric charges cannot travel easily. A conductor is a material, such as metal wire, through which electric charges can travel easily. ...
AO Electricity
AO Electricity

... proportions of positive and negative charges, making the materials as a whole electrically neutral. Negative charges, being associated with electrons, are far more mobile in materials than positive charges are. A very small excess or deficit of negative charges in a material produces noticeable elec ...
Lighting Load Protection
Lighting Load Protection

... conductors supplied by a single phase transformer with a 2-wire secondary, or a three-phase delta-delta transformer with a 3-wire, single voltage secondary, it is recommended that these conductors be protected. Primary overcurrent devices cannot adequately provide protection during internal transfor ...
series rated combinations
series rated combinations

Required Output per Foot (Meter)
Required Output per Foot (Meter)

electric rewind installation instructions (h-8823)
electric rewind installation instructions (h-8823)

... The circuit breaker should be firmly mounted using the two mounting holes provided. The mounting position should be well removed from any abnormal sources of heat such as an exhaust manifold or radiator. To use the SDLM breaker satisfactorily, a small mounting bracket, available from us as part #991 ...
Magnetic
Magnetic

... Magnetic - A Magnetic material is a substance that is attracted to a magnet and can act like a magnet. Magnetic field - A magnetic field is area of attraction and repulsion that surrounds a magnet. Magnetically - If two objects magnetically attract each other, they are pulled toward each other. Iron ...
30104 Operate electrical switchgear in the electricity
30104 Operate electrical switchgear in the electricity

drawing title - Eagle County
drawing title - Eagle County

... THE DRAWINGS INDICATE THE GENERAL ARRANGEMENT OF CIRCUITS AND OUTLETS, LOCATIONS OF SWITCHES, PANELBOARDS AND OTHER WORK. INFORMATION SHOWN ON THE DRAWINGS IS DIAGRAMMATIC, HOWEVER DO NOT REVISE THE CIRCUITING SHOWN WITHOUT SPECIFIC APPROVAL OF THE ENGINEER. DRAWINGS AND SPECIFICATIONS ARE COMPLEMEN ...
High voltage circuit breaker standards—comparative guide
High voltage circuit breaker standards—comparative guide

... last several decades. Contacts do not corrode, and arcing on some vacuum interruptions is no more than defuse blue plasma. Synthetic lubricants and precision computer designed parts allow manufacturers to design circuit breakers with capabilities well beyond the limits shown in Table 2. ...
WIRE 1 = WIRE 2 = WIRE 3 - Bishopston Comprehensive School
WIRE 1 = WIRE 2 = WIRE 3 - Bishopston Comprehensive School

< 1 ... 41 42 43 44 45 46 47 48 49 ... 91 >

National Electrical Code

The National Electrical Code (NEC), or NFPA 70, is a regionally adoptable standard for the safe installation of electrical wiring and equipment in the United States. It is part of the National Fire Codes series published by the National Fire Protection Association (NFPA), a private trade association. Despite the use of the term ""national"", it is not a federal law. It is typically adopted by states and municipalities in an effort to standardize their enforcement of safe electrical practices. In some cases, the NEC is amended, altered and may even be rejected in lieu of regional regulations as voted on by local governing bodies.The ""authority having jurisdiction"" inspects for compliance with these minimum standards.