Type HVH Horizontal/Vertical Unit Heater
... 1. Use 14 gauge copper, NEC Class 1, 600V rated insulated wire. Wiring must meet all Local and NEC requirements for 480-volt service. 2. Install the remote fan switch in standard wall box in any convenient location that is protected from traffic or other accidental damage. 3. Connect the 14 gauge ...
... 1. Use 14 gauge copper, NEC Class 1, 600V rated insulated wire. Wiring must meet all Local and NEC requirements for 480-volt service. 2. Install the remote fan switch in standard wall box in any convenient location that is protected from traffic or other accidental damage. 3. Connect the 14 gauge ...
ST5484E Seismic Velocity 4-20mA Transmitter - Metrix
... Excellent Moisture Resistance – The 2-pin MIL connector version is hermetically sealed to provide an IP67-rated enclosure. Flying lead and terminal block versions are fully potted and rated to IP56 when installed with optional IEC conduit elbow Hazardous Area Approvals – North American (CSA), Brazil ...
... Excellent Moisture Resistance – The 2-pin MIL connector version is hermetically sealed to provide an IP67-rated enclosure. Flying lead and terminal block versions are fully potted and rated to IP56 when installed with optional IEC conduit elbow Hazardous Area Approvals – North American (CSA), Brazil ...
Section 2A-8 Voice, Data, and Video Struct Cab
... system via a fiber backbone connection. 9. Electrical wiring shall not be bundled in the same pathway as the communications wiring unless the pathway contains partitions for power and communications wiring UL listed for this purpose. Combination power and data outlet boxes (typically used in floor i ...
... system via a fiber backbone connection. 9. Electrical wiring shall not be bundled in the same pathway as the communications wiring unless the pathway contains partitions for power and communications wiring UL listed for this purpose. Combination power and data outlet boxes (typically used in floor i ...
LP-FXZAN13-0 Zone Controller and Actuator
... Make all wiring connections in accordance with the National Electrical Code (NEC) and state and local regulations. For transformer primaries above 150 VAC, the secondary must be earth-grounded at the transformer to meet NEC. Since the power supply for the FXZAN is not isolated, earth ground can be i ...
... Make all wiring connections in accordance with the National Electrical Code (NEC) and state and local regulations. For transformer primaries above 150 VAC, the secondary must be earth-grounded at the transformer to meet NEC. Since the power supply for the FXZAN is not isolated, earth ground can be i ...
Electromagnets - Cockeysville Middle
... André Ampere followed up on this discovery and found that two parallel wires carrying electric currents running the same direction attracted each other. This observation led to the creation of a solenoid or coil as shown in Figure 1. In the solenoid, the magnetic field created by a loop of wire carr ...
... André Ampere followed up on this discovery and found that two parallel wires carrying electric currents running the same direction attracted each other. This observation led to the creation of a solenoid or coil as shown in Figure 1. In the solenoid, the magnetic field created by a loop of wire carr ...
Update on 2008 Code Changes
... The essential electrical system shall meet the requirements of Article 700, except as amended by Article 517. (Note: Article 517 has no amendment to the selective coordination requirement, therefore selective coordination is required.) Article 620 Elevators 620.62 Selective Coordination Where more t ...
... The essential electrical system shall meet the requirements of Article 700, except as amended by Article 517. (Note: Article 517 has no amendment to the selective coordination requirement, therefore selective coordination is required.) Article 620 Elevators 620.62 Selective Coordination Where more t ...
- Underhill International
... This procedure checks for the presence of any bad insulation along the 2 wire path which would allow current to leak into the earth. 1. Switch off the ICC. 2. Ensure the 2 wire path is disconnected from the Decoder Module Ll & L2 3. Instead, connect the 2 wire path to the 30V output of the TRANSFRMR ...
... This procedure checks for the presence of any bad insulation along the 2 wire path which would allow current to leak into the earth. 1. Switch off the ICC. 2. Ensure the 2 wire path is disconnected from the Decoder Module Ll & L2 3. Instead, connect the 2 wire path to the 30V output of the TRANSFRMR ...
TrueAlert Multi-Candela Notification Appliances
... background allows the selected intensity to be seen at the side of the strobe lens. ...
... background allows the selected intensity to be seen at the side of the strobe lens. ...
Electromagnet Review Slides
... 1. You can increase the current in the solenoid. 2. You can add more loops of wire to the solenoid. 3. You can wind the coils of the solenoid closer together. 4. You can use a stronger ferromagnetic material for the core. ...
... 1. You can increase the current in the solenoid. 2. You can add more loops of wire to the solenoid. 3. You can wind the coils of the solenoid closer together. 4. You can use a stronger ferromagnetic material for the core. ...
The Polarization Cell Replacement (PCR)
... (2) over-voltage protection of insulated joints and similar structures and equipment, (3) DC isolation and AC grounding of cathodically protected structures and electrical equipment in cathodically protected structures. The PCR can be used in a variety of different applications, each of which requi ...
... (2) over-voltage protection of insulated joints and similar structures and equipment, (3) DC isolation and AC grounding of cathodically protected structures and electrical equipment in cathodically protected structures. The PCR can be used in a variety of different applications, each of which requi ...
PowerPoint Ch 32
... Lecture PowerPoint Physics for Scientists and Engineers, 3rd edition Fishbane Gasiorowicz Thornton © 2005 Pearson Prentice Hall This work is protected by United States copyright laws and is provided solely for the use of instructors in teaching their courses and assessing student learning. Dissemina ...
... Lecture PowerPoint Physics for Scientists and Engineers, 3rd edition Fishbane Gasiorowicz Thornton © 2005 Pearson Prentice Hall This work is protected by United States copyright laws and is provided solely for the use of instructors in teaching their courses and assessing student learning. Dissemina ...
HEWITT PYROMETERS Installation Instructions
... After installation of all system components is completed and power is applied, simply connect the corresponding tester leads to the pyrometer terminals, press the power button and turn test knob until pointer indicates desired switch point. If Pyro-Alarm does not switch, adjust alarm as needed. Repe ...
... After installation of all system components is completed and power is applied, simply connect the corresponding tester leads to the pyrometer terminals, press the power button and turn test knob until pointer indicates desired switch point. If Pyro-Alarm does not switch, adjust alarm as needed. Repe ...
Draw wire encoder
... It is guaranteed by the mechanical construction that the wire unwraps evenly on the drum. The dimension of the drum (diameter and width) and the diameter of the wire determine the maximum wire length. The measuring accuracy is only for the first rolled up situation accurately defined. The offered me ...
... It is guaranteed by the mechanical construction that the wire unwraps evenly on the drum. The dimension of the drum (diameter and width) and the diameter of the wire determine the maximum wire length. The measuring accuracy is only for the first rolled up situation accurately defined. The offered me ...
IF 1670 Revision 1
... To avoid the risk of fire, explosion, or electric shock, this product should be installed, inspected, and maintained by a qualified electrician only, in accordance with all applicable electrical codes. ...
... To avoid the risk of fire, explosion, or electric shock, this product should be installed, inspected, and maintained by a qualified electrician only, in accordance with all applicable electrical codes. ...
The MWS Splitter (SP)
... MWS, Modular Wiring Systems, provide low cost installation of branch circuit wiring for lighting and power. Using modular components that plug together, MWS can be installed in a fraction of the time of hardwiring. Plus, MWS offers the advantage of relocating fixtures and outlets in future renovatio ...
... MWS, Modular Wiring Systems, provide low cost installation of branch circuit wiring for lighting and power. Using modular components that plug together, MWS can be installed in a fraction of the time of hardwiring. Plus, MWS offers the advantage of relocating fixtures and outlets in future renovatio ...