
Product Catalog
... and utilizes solid-state electronics to accurately measure up to 1/100mm. Benefits • Measures gemstone dimensions with accuracy to 0.01mm • Direct carat conversion for round brilliant-cut diamonds • Clear and visible digital display for ease of reading measurements • Simple and easy-to-use • Light a ...
... and utilizes solid-state electronics to accurately measure up to 1/100mm. Benefits • Measures gemstone dimensions with accuracy to 0.01mm • Direct carat conversion for round brilliant-cut diamonds • Clear and visible digital display for ease of reading measurements • Simple and easy-to-use • Light a ...
Electronics Lab Manual
... the sufficient voltages across the transistor junctions. This amplifier set up is almost independent of β. R1 and R2 are designed such that a stable voltage drop exists across them even when the base current varies. For this, current through R1 and R2 is assumed to be the same and it is much higher ...
... the sufficient voltages across the transistor junctions. This amplifier set up is almost independent of β. R1 and R2 are designed such that a stable voltage drop exists across them even when the base current varies. For this, current through R1 and R2 is assumed to be the same and it is much higher ...
VN751PT
... where -IGND is the DC reverse ground pin current and can be found in the absolute maximum rating section of the device datasheet. The power dissipation associated to RGND during reverse polarity condition is: PD = (-VCC)2/RGND This resistor can be shared by several different ICs. In such case IS val ...
... where -IGND is the DC reverse ground pin current and can be found in the absolute maximum rating section of the device datasheet. The power dissipation associated to RGND during reverse polarity condition is: PD = (-VCC)2/RGND This resistor can be shared by several different ICs. In such case IS val ...
Laboratory 1 Ohm`s Law
... The oscilloscope acts like a DMM for time-varying signals, but one way in which it differs is the way in which it sees ground. The DMM measures voltage between its two probes. The oscilloscope measures voltage between its probe and the ground provided by the third prong of its electrical cord. This ...
... The oscilloscope acts like a DMM for time-varying signals, but one way in which it differs is the way in which it sees ground. The DMM measures voltage between its two probes. The oscilloscope measures voltage between its probe and the ground provided by the third prong of its electrical cord. This ...
Study of Material Evaluation Probe Using a Longitudinal Wave and
... Transmitting a longitudinal wave and a traverse wave into a composite material in a molten state has been studied in the online control of the composite material which cannot be evaluated by a conventional ultrasonic sensor as a final analysis, using the difference in the propagation characteristics ...
... Transmitting a longitudinal wave and a traverse wave into a composite material in a molten state has been studied in the online control of the composite material which cannot be evaluated by a conventional ultrasonic sensor as a final analysis, using the difference in the propagation characteristics ...
Lab 5 - Portal UniMAP
... 4. Determine the number of horizontal divisions for one complete cycle of either waveform denoted as D1 and the horizontal divisions for the phase shift between the Vs and VR denoted as D2. Now determine the phase shift, 1 in degrees using Eq. (5.1). Insert all the measured values in Table 1. From ...
... 4. Determine the number of horizontal divisions for one complete cycle of either waveform denoted as D1 and the horizontal divisions for the phase shift between the Vs and VR denoted as D2. Now determine the phase shift, 1 in degrees using Eq. (5.1). Insert all the measured values in Table 1. From ...
Digital Panel Meters Modular Indicator and Controller Type UDM35
... Alarm set-points are directly programmable from the measuring mode. Depending on the module: measuring range and type of probe (resistance, RTD thermoresistance, TC thermocouple) or measuring type (TRMS or DC). Displayed functions of channel A and B: F1: scaled value of channel A; F2: 1/A; F3: A-B; ...
... Alarm set-points are directly programmable from the measuring mode. Depending on the module: measuring range and type of probe (resistance, RTD thermoresistance, TC thermocouple) or measuring type (TRMS or DC). Displayed functions of channel A and B: F1: scaled value of channel A; F2: 1/A; F3: A-B; ...
Impedance Matching and Matching Networks
... components to be controlled for adjusting the real and imaginary part of the impedance. Practical component values - some of configurations require either very low inductance values or very high capacitance values which is impossible to make especially when you have to design auto matching network w ...
... components to be controlled for adjusting the real and imaginary part of the impedance. Practical component values - some of configurations require either very low inductance values or very high capacitance values which is impossible to make especially when you have to design auto matching network w ...
Chapter 7
... 7.3 Step Response of RL and RC Circuits We are going to find the currents and voltages in 1st order RL and RC circuits when a DC voltage or current is suddenly applied. The Step Response of an RL Circuit The switch is closed at t = 0 , the task is to find the expressions for the current in the circ ...
... 7.3 Step Response of RL and RC Circuits We are going to find the currents and voltages in 1st order RL and RC circuits when a DC voltage or current is suddenly applied. The Step Response of an RL Circuit The switch is closed at t = 0 , the task is to find the expressions for the current in the circ ...
16 Channel High Voltage Board
... voltage scale to 200mVDC with the time base at 50us/division. 3. Turn on the cursor data function dt and the dV on the oscilloscope. 4. Make sure the piezo material is not connected to the high voltage connector assembly. Turn on the high voltage power supply from the power strip. Adjust the voltage ...
... voltage scale to 200mVDC with the time base at 50us/division. 3. Turn on the cursor data function dt and the dV on the oscilloscope. 4. Make sure the piezo material is not connected to the high voltage connector assembly. Turn on the high voltage power supply from the power strip. Adjust the voltage ...
INA114 数据资料 dataSheet 下载
... A combination of common-mode and differential input signals can cause the output of A1 or A2 to saturate. Figure 4 shows the output voltage swing of A1 and A2 expressed in terms of a common-mode and differential input voltages. Output swing capability of these internal amplifiers is the same as the ...
... A combination of common-mode and differential input signals can cause the output of A1 or A2 to saturate. Figure 4 shows the output voltage swing of A1 and A2 expressed in terms of a common-mode and differential input voltages. Output swing capability of these internal amplifiers is the same as the ...
Current Switching with High Voltage Air Disconnector
... positive or negative. As the time passes a series of successive Switching operation in power stations and substations, high- strikes will keep occurring at reduced amplitude, until the voltage faults and lightning cause high levels of high contacts touch. The highest transient overvoltage therefore ...
... positive or negative. As the time passes a series of successive Switching operation in power stations and substations, high- strikes will keep occurring at reduced amplitude, until the voltage faults and lightning cause high levels of high contacts touch. The highest transient overvoltage therefore ...
Test probe
A test probe (test lead, test prod, or scope probe) is a physical device used to connect electronic test equipment to a device under test (DUT). They range from very simple, robust devices to complex probes that are sophisticated, expensive, and fragile.