
BD9123MUV
... When the control mode is shifted by PWM from heavier load to the one for lighter load or vice versa, the switching pulse is designed to turn OFF with the device held operating in normal PWM control loop. This allows linear operation without voltage drop or deterioration in transient response during ...
... When the control mode is shifted by PWM from heavier load to the one for lighter load or vice versa, the switching pulse is designed to turn OFF with the device held operating in normal PWM control loop. This allows linear operation without voltage drop or deterioration in transient response during ...
Episode 118 - Teaching Advanced Physics
... The effect of the load on output With strong groups you might discuss the effect of loading a potential divider on its output voltage. The ideas to get across are: Connecting a load across R1 reduces the output voltage. This is because the effective resistance in the lower arm of the potential divid ...
... The effect of the load on output With strong groups you might discuss the effect of loading a potential divider on its output voltage. The ideas to get across are: Connecting a load across R1 reduces the output voltage. This is because the effective resistance in the lower arm of the potential divid ...
ADCMP361 数据手册DataSheet 下载
... The ADCMP361 is designed to operate from 1.7 V to 5.5 V. A 100 nF decoupling capacitor is recommended between VDD and GND. ...
... The ADCMP361 is designed to operate from 1.7 V to 5.5 V. A 100 nF decoupling capacitor is recommended between VDD and GND. ...
MAX1838 Dual USB Switch with Fault Blanking and Autoreset General Description
... Load conditions may require additional bulk capacitance to maintain AUX voltage regulation. ...
... Load conditions may require additional bulk capacitance to maintain AUX voltage regulation. ...
TPS60240 数据资料 dataSheet 下载
... voltage. Terminal C1+ is connected to VIN, and C1– is connected to GND. In the second phase, C1– is connected to the output of the operational amplifier, and C1+ is connected to VOUT. The operational amplifier then adjusts its output until the output VOUT delivers the correct voltage to make the res ...
... voltage. Terminal C1+ is connected to VIN, and C1– is connected to GND. In the second phase, C1– is connected to the output of the operational amplifier, and C1+ is connected to VOUT. The operational amplifier then adjusts its output until the output VOUT delivers the correct voltage to make the res ...
Interfacing to MM74HC High-Speed CMOS Logic Interfacing to
... VCC. The value of the resistor should be chosen based on the LSTTL and CMOS fanout of the LS gate. Figure 2 shows the range of pull-up resistors values versus LS fanout that can be used. For example, if an LSTTL device is driving only CMOS circuits, the resistor value is chosen from the left axis wh ...
... VCC. The value of the resistor should be chosen based on the LSTTL and CMOS fanout of the LS gate. Figure 2 shows the range of pull-up resistors values versus LS fanout that can be used. For example, if an LSTTL device is driving only CMOS circuits, the resistor value is chosen from the left axis wh ...
LTM8023 - 2A, 36V DC/DC Step-Down uModule Regulator
... The LTM8023 is a standalone nonisolated step-down switching DC/DC power supply. It can deliver up to 2A of DC output current with only bulk external input and output capacitors. This module provides a precisely regulated output voltage programmable via one external resistor from 0.8VDC to 10VDC. The ...
... The LTM8023 is a standalone nonisolated step-down switching DC/DC power supply. It can deliver up to 2A of DC output current with only bulk external input and output capacitors. This module provides a precisely regulated output voltage programmable via one external resistor from 0.8VDC to 10VDC. The ...
MAX531/MAX538/MAX539 +5V, Low-Power, Voltage-Output, Serial 12-Bit DACs _______________General Description
... at REFOUT. The output stage can source and sink current, so REFOUT can settle to the correct voltage quickly in response to code-dependent loading changes. Typically, source current is 5mA and sink current is 100µA. REFOUT connects the internal reference to the R-2R DAC ladder at REFIN. The R-2R lad ...
... at REFOUT. The output stage can source and sink current, so REFOUT can settle to the correct voltage quickly in response to code-dependent loading changes. Typically, source current is 5mA and sink current is 100µA. REFOUT connects the internal reference to the R-2R DAC ladder at REFIN. The R-2R lad ...
Dual Output BWR Models
... gradually so as not to cause any erratic behavior on the converters outputs. A slight degradation in efficiency will occur while this internal load is activated. Filtering and Noise Reduction The BWR 33 Watt Series Converters achieve their rated ripple and noise specifications with the use of 1μF outp ...
... gradually so as not to cause any erratic behavior on the converters outputs. A slight degradation in efficiency will occur while this internal load is activated. Filtering and Noise Reduction The BWR 33 Watt Series Converters achieve their rated ripple and noise specifications with the use of 1μF outp ...
MAX8563/MAX8564/MAX8564A ±1%, Ultra-Low Output Voltage, Dual and Triple Linear n-FET Controllers General Description
... The maximum input voltage to the drain of the n-MOSFET is a function of the breakdown voltage and the thermal conditions during operation. The breakdown voltage from drain to source is normally provided in the MOSFET data sheet. The theoretical maximum input voltage is the set output voltage plus th ...
... The maximum input voltage to the drain of the n-MOSFET is a function of the breakdown voltage and the thermal conditions during operation. The breakdown voltage from drain to source is normally provided in the MOSFET data sheet. The theoretical maximum input voltage is the set output voltage plus th ...
Chapter 10 Analyzing Electrical Yields
... and transient analysis. They can generate scatter plots for operating point analysis and family of curves plots for DC, AC, and transient analysis. The .MEASURE statement in Star-Hspice is used with yield analyses, allowing you to see distributions of delay times, power, or any other characteristic ...
... and transient analysis. They can generate scatter plots for operating point analysis and family of curves plots for DC, AC, and transient analysis. The .MEASURE statement in Star-Hspice is used with yield analyses, allowing you to see distributions of delay times, power, or any other characteristic ...
Datasheet
... The input and output negative voltage ratings may be exceeded if the input and output clamp current ratings are observed. ...
... The input and output negative voltage ratings may be exceeded if the input and output clamp current ratings are observed. ...
LTC3672B-1
... Many different sizes and shapes of inductors are available from numerous manufacturers. Choosing the right inductor from such a large selection of devices can be overwhelming, but following a few basic guidelines will make the selection process much simpler. The buck regulator is designed to work wi ...
... Many different sizes and shapes of inductors are available from numerous manufacturers. Choosing the right inductor from such a large selection of devices can be overwhelming, but following a few basic guidelines will make the selection process much simpler. The buck regulator is designed to work wi ...
Theoretical Comparison, Equivalent Transformation, and
... periodic overlapping and separation process of the two groups of sectors on the two concentric and closely contacted disks is achieved by relative rotation. The basic structure of the rotating TENG is composed of two disk-shaped components with several sectors each. The working principle is based on ...
... periodic overlapping and separation process of the two groups of sectors on the two concentric and closely contacted disks is achieved by relative rotation. The basic structure of the rotating TENG is composed of two disk-shaped components with several sectors each. The working principle is based on ...