MAX4554/MAX4555/MAX4556 Force-Sense Switches General Description Features
... switches configured as two triple-pole/single-throw (3PST) normally open (NO) switches. The MAX4555 contains four independent single-pole/single-throw (SPST) normally closed (NC) switches, two force switches, and two sense switches. The MAX4556 contains three independent single-pole/double-throw (SP ...
... switches configured as two triple-pole/single-throw (3PST) normally open (NO) switches. The MAX4555 contains four independent single-pole/single-throw (SPST) normally closed (NC) switches, two force switches, and two sense switches. The MAX4556 contains three independent single-pole/double-throw (SP ...
Reciprocity condition in terms of two port parameters
... If we are interested in the solution of the current or voltage of a small part of the network, it is convenient from the computational point of view to simplify the network, except that small part in question, by a simple equivalent. This is achieved by Thevinin’s Theorem or ...
... If we are interested in the solution of the current or voltage of a small part of the network, it is convenient from the computational point of view to simplify the network, except that small part in question, by a simple equivalent. This is achieved by Thevinin’s Theorem or ...
LM139/LM239/LM339/LM2901/LM3302 Low Power Low Offset
... Note 5: The direction of the input current is out of the IC due to the PNP input stage. This current is essentially constant, independent of the state of the output so no loading change exists on the reference or input lines. Note 6: The input common-mode voltage or either input signal voltage shoul ...
... Note 5: The direction of the input current is out of the IC due to the PNP input stage. This current is essentially constant, independent of the state of the output so no loading change exists on the reference or input lines. Note 6: The input common-mode voltage or either input signal voltage shoul ...
T3029919 - Telecommunications Industry Association
... This Standard does not describe any requirements for error performance either for a complete system or any system components. It should not be assumed that compliance with this Standard will produce error rates that are acceptable in any particular application. ...
... This Standard does not describe any requirements for error performance either for a complete system or any system components. It should not be assumed that compliance with this Standard will produce error rates that are acceptable in any particular application. ...
ESCC 2134000 (Resistors and Thermistors)
... (a) For high values of resistance, the limiting element voltage may prevent the rated dissipation being attained. (b) For the dissipation at temperatures other than +70°C, reference should be made to the rating graphs for variable resistors or the relevant Detail Specification. (c) For situations wh ...
... (a) For high values of resistance, the limiting element voltage may prevent the rated dissipation being attained. (b) For the dissipation at temperatures other than +70°C, reference should be made to the rating graphs for variable resistors or the relevant Detail Specification. (c) For situations wh ...
IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE) e-ISSN: 2278-1676,p-ISSN: 2320-3331,
... switching schemes and each one will have its own advantages and disadvantages. Efficiency and output distortion are two important factors governing the choice of inverter system. In 2009 Wuhua Li et al presented a review paper of Non-Isolated High Step-Up DC/DC Converters in Renewable Energy Applica ...
... switching schemes and each one will have its own advantages and disadvantages. Efficiency and output distortion are two important factors governing the choice of inverter system. In 2009 Wuhua Li et al presented a review paper of Non-Isolated High Step-Up DC/DC Converters in Renewable Energy Applica ...
ADV7283 - Analog Devices
... The absolute maximum ratings assume that the DGND pins and the exposed pad of the ADV7283 are connected together to a common ground plane (GND). This is part of the recommended layout scheme. See the PCB Layout Recommendations section for more information. The absolute maximum ratings are stated in ...
... The absolute maximum ratings assume that the DGND pins and the exposed pad of the ADV7283 are connected together to a common ground plane (GND). This is part of the recommended layout scheme. See the PCB Layout Recommendations section for more information. The absolute maximum ratings are stated in ...
doc - Montana State University
... The switch is normally open. In this configuration the signal S2 is 'high' because the node is connected to +5 V (Vcc) through the 10 k resistor: since no current flows in the resistor Ohm's Law says that the voltage across the resistor must be zero, so S2 must be at the same voltage as Vcc. If the ...
... The switch is normally open. In this configuration the signal S2 is 'high' because the node is connected to +5 V (Vcc) through the 10 k resistor: since no current flows in the resistor Ohm's Law says that the voltage across the resistor must be zero, so S2 must be at the same voltage as Vcc. If the ...
MAX4245/MAX4246/MAX4247 Ultra-Small, Rail-to-Rail I/O with Disable, Single-/Dual-Supply, Low-Power Op Amps General Description
... The MAX4245/MAX4246/MAX4247 family of low-cost op amps offer rail-to-rail inputs and outputs, draw only 320µA of quiescent current, and operate from a single +2.5V to +5.5V supply. For additional power conservation, the MAX4245/MAX4247 offer a low-power shutdown mode that reduces supply current to 5 ...
... The MAX4245/MAX4246/MAX4247 family of low-cost op amps offer rail-to-rail inputs and outputs, draw only 320µA of quiescent current, and operate from a single +2.5V to +5.5V supply. For additional power conservation, the MAX4245/MAX4247 offer a low-power shutdown mode that reduces supply current to 5 ...
A. Bioimpedance monitoring for physicians: an overview
... A. Bioimpedance monitoring for physicians: an overview 1 Sometimes I have had to explain the basics of electrical Bioimpedance Monitoring (BM) to physicians, biologists or veterinarians, all of them from the biomedical community and familiarized with cell biology. In general, those professionals are ...
... A. Bioimpedance monitoring for physicians: an overview 1 Sometimes I have had to explain the basics of electrical Bioimpedance Monitoring (BM) to physicians, biologists or veterinarians, all of them from the biomedical community and familiarized with cell biology. In general, those professionals are ...
LM45 SOT-23 Precision Centigrade Temperature Sensors
... The LM45 can be applied easily in the same way as other integrated-circuit temperature sensors. It can be glued or cemented to a surface and its temperature will be within about 0.2°C of the surface temperature. This presumes that the ambient air temperature is almost the same as the surface tempera ...
... The LM45 can be applied easily in the same way as other integrated-circuit temperature sensors. It can be glued or cemented to a surface and its temperature will be within about 0.2°C of the surface temperature. This presumes that the ambient air temperature is almost the same as the surface tempera ...
Valve RF amplifier
A valve RF amplifier (UK and Aus.) or tube amplifier (U.S.), is a device for electrically amplifying the power of an electrical radio frequency signal.Low to medium power valve amplifiers for frequencies below the microwaves were largely replaced by solid state amplifiers during the 1960s and 1970s, initially for receivers and low power stages of transmitters, transmitter output stages switching to transistors somewhat later. Specially constructed valves are still in use for very high power transmitters, although rarely in new designs.