MAX366/MAX367 Signal-Line Circuit Protectors _______________General Description ____________________________Features
... the MAX367 contains eight. They can protect analog signals using either unipolar (4.5V to 36V) or bipolar (±2.25V to ±18V) power supplies. Each protector is symmetrical. Input and output terminals may be freely interchanged. These devices are voltage-sensitive MOSFET transistor arrays that are norma ...
... the MAX367 contains eight. They can protect analog signals using either unipolar (4.5V to 36V) or bipolar (±2.25V to ±18V) power supplies. Each protector is symmetrical. Input and output terminals may be freely interchanged. These devices are voltage-sensitive MOSFET transistor arrays that are norma ...
Electrical Circuits
... In a simple series circuit, everything is connected in one loop across the terminals of the battery. So there are not any points where the current can split or join (these are called junctions). This circuit has two lamps connected in series. Circuits are always drawn using straight lines. ...
... In a simple series circuit, everything is connected in one loop across the terminals of the battery. So there are not any points where the current can split or join (these are called junctions). This circuit has two lamps connected in series. Circuits are always drawn using straight lines. ...
OPA602 High-Speed Precision Difet OPERATIONAL AMPLIFIER
... Important Information and Disclaimer:The information provided on this page represents TI's knowledge and belief as of the date that it is provided. TI bases its knowledge and belief on information provided by third parties, and makes no representation or warranty as to the accuracy of such informati ...
... Important Information and Disclaimer:The information provided on this page represents TI's knowledge and belief as of the date that it is provided. TI bases its knowledge and belief on information provided by third parties, and makes no representation or warranty as to the accuracy of such informati ...
Experiment 6: Rectifiers
... Because the earth of both the oscilloscope and Function Generator are not isolated, scope measurements for the circuits of Figures 2.2 and 2.3 are not possible using the known conventional techniques. Thus, the scope has to be set up to function in differential mode. A consequence of this set up is ...
... Because the earth of both the oscilloscope and Function Generator are not isolated, scope measurements for the circuits of Figures 2.2 and 2.3 are not possible using the known conventional techniques. Thus, the scope has to be set up to function in differential mode. A consequence of this set up is ...
ECE 4760 - Cornell ECE
... 2. A critical component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness. ...
... 2. A critical component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness. ...
Triple Differential Receiver with 200 Meter Adjustable Cable Equalization AD8124
... rating only; functional operation of the device at these or any other conditions above those indicated in the operational section of this specification is not implied. Exposure to absolute maximum rating conditions for extended periods may affect device reliability. ...
... rating only; functional operation of the device at these or any other conditions above those indicated in the operational section of this specification is not implied. Exposure to absolute maximum rating conditions for extended periods may affect device reliability. ...
CTFinal
... A ray of light is sent into an optic fiber at an angle such that the angle with the normal to the pipe is . The fiber has an inner core with index ni and an outer cladding with index no. If no/ni is not large enough there will be no internal reflection. What is the minimum value of no/ni required f ...
... A ray of light is sent into an optic fiber at an angle such that the angle with the normal to the pipe is . The fiber has an inner core with index ni and an outer cladding with index no. If no/ni is not large enough there will be no internal reflection. What is the minimum value of no/ni required f ...
Smps repair sometimes can be easy and sometimes are quite
... outputs, some have five and so on. Each of the output is connected to an individual circuit. For instance, a 6.3 volt output supply is send to the picture tube so that it could light up and heat the cathode gun. A 5 volt supply will usually entered into microprocessor and EEPROM IC as vcc supply, 60 ...
... outputs, some have five and so on. Each of the output is connected to an individual circuit. For instance, a 6.3 volt output supply is send to the picture tube so that it could light up and heat the cathode gun. A 5 volt supply will usually entered into microprocessor and EEPROM IC as vcc supply, 60 ...
CEC Co. Ltd. - AudioVideoMir.com.ua
... The unique combination of current injection and LEF Single Ended Class A technology in only one amplifier per balanced analog output stage provides you today’s best possible sound quality. The amplifier section runs without overall negative feedback. No dynamic distortions are created by the amplifi ...
... The unique combination of current injection and LEF Single Ended Class A technology in only one amplifier per balanced analog output stage provides you today’s best possible sound quality. The amplifier section runs without overall negative feedback. No dynamic distortions are created by the amplifi ...
Dual Wideband, High Output Current Operational Amplifier with
... Line Modem driver applications. Operating on a single +12V supply, the OPA2670 consumes a low 30.5mA quiescent current to deliver a very high 700mA output current. This output current supports even the most demanding xDSL requirements with greater than 450mA minimum output current (+25°C minimum val ...
... Line Modem driver applications. Operating on a single +12V supply, the OPA2670 consumes a low 30.5mA quiescent current to deliver a very high 700mA output current. This output current supports even the most demanding xDSL requirements with greater than 450mA minimum output current (+25°C minimum val ...
Subiecte de examen la CEF din sesiunile anterioare
... T1. 1.5p. What is the circuit for the NAND CMOS gate? Describe the operation of the circuit by means of the truth table and the states of all transistors (on or off). T2. 1.5p. The operational amplifier: symbol; terminals; operation equation; properties of the ideal op amp. E1. Assume OA – ideal, ra ...
... T1. 1.5p. What is the circuit for the NAND CMOS gate? Describe the operation of the circuit by means of the truth table and the states of all transistors (on or off). T2. 1.5p. The operational amplifier: symbol; terminals; operation equation; properties of the ideal op amp. E1. Assume OA – ideal, ra ...
Pure water is non-conducting Gas discharges Current– flow of
... current Æ you must check that whatever is plugged into it will not draw more current than the cord can handle safely. • power strips are also rated for maximum current Æ since they have multiple imputs you must check that the total current drawn by everything on it does not exceed the current rating ...
... current Æ you must check that whatever is plugged into it will not draw more current than the cord can handle safely. • power strips are also rated for maximum current Æ since they have multiple imputs you must check that the total current drawn by everything on it does not exceed the current rating ...
Addendum to kWh Meter Installation Instructions For Use - E-Mon
... Transformers) and CTs (Current Transformers) supplied by others. The E-MON meter is installed using the secondary outputs of these devices. High voltage PTs reduce the primary voltage (4160v, 13200v, etc.) to a Secondary output of 120v. This secondary is connected to the E-MON meter voltage inputs a ...
... Transformers) and CTs (Current Transformers) supplied by others. The E-MON meter is installed using the secondary outputs of these devices. High voltage PTs reduce the primary voltage (4160v, 13200v, etc.) to a Secondary output of 120v. This secondary is connected to the E-MON meter voltage inputs a ...
RT8749 - Richtek
... fan motor's speed to this target speed by adjusting the switching duty ratio of the output drivers. It should be noted that the input PWM frequency is independent of the switching frequency of the output drivers. Hence, the input PWM frequency can be chosen within a wide range, from 100Hz to 100kHz, ...
... fan motor's speed to this target speed by adjusting the switching duty ratio of the output drivers. It should be noted that the input PWM frequency is independent of the switching frequency of the output drivers. Hence, the input PWM frequency can be chosen within a wide range, from 100Hz to 100kHz, ...
Operational amplifier
An operational amplifier (""op-amp"") is a DC-coupled high-gain electronic voltage amplifier with a differential input and, usually, a single-ended output. In this configuration, an op-amp produces an output potential (relative to circuit ground) that is typically hundreds of thousands of times larger than the potential difference between its input terminals.Operational amplifiers had their origins in analog computers, where they were used to do mathematical operations in many linear, non-linear and frequency-dependent circuits. The popularity of the op-amp as a building block in analog circuits is due to its versatility. Due to negative feedback, the characteristics of an op-amp circuit, its gain, input and output impedance, bandwidth etc. are determined by external components and have little dependence on temperature coefficients or manufacturing variations in the op-amp itself.Op-amps are among the most widely used electronic devices today, being used in a vast array of consumer, industrial, and scientific devices. Many standard IC op-amps cost only a few cents in moderate production volume; however some integrated or hybrid operational amplifiers with special performance specifications may cost over $100 US in small quantities. Op-amps may be packaged as components, or used as elements of more complex integrated circuits.The op-amp is one type of differential amplifier. Other types of differential amplifier include the fully differential amplifier (similar to the op-amp, but with two outputs), the instrumentation amplifier (usually built from three op-amps), the isolation amplifier (similar to the instrumentation amplifier, but with tolerance to common-mode voltages that would destroy an ordinary op-amp), and negative feedback amplifier (usually built from one or more op-amps and a resistive feedback network).