ADA4310-1 数据手册DataSheet 下载
... covering all unused portions of the component side of the board to provide a low impedance return path. Removing the ground plane on all layers from the area near the input and output pins reduces stray capacitance, particularly in the area of the inverting inputs. Signal lines connecting the feedba ...
... covering all unused portions of the component side of the board to provide a low impedance return path. Removing the ground plane on all layers from the area near the input and output pins reduces stray capacitance, particularly in the area of the inverting inputs. Signal lines connecting the feedba ...
ADS1208 数据资料 dataSheet 下载
... The ADS1208 is a 2nd-order ∆Σ (delta-sigma) modulator operating at a 10MHz clock rate. The specified input range is ±100mV, optimized for current measurement with a Hall sensor, especially in motor control applications. The ADS1208 contains a programmable current source for sensor biasing and has in ...
... The ADS1208 is a 2nd-order ∆Σ (delta-sigma) modulator operating at a 10MHz clock rate. The specified input range is ±100mV, optimized for current measurement with a Hall sensor, especially in motor control applications. The ADS1208 contains a programmable current source for sensor biasing and has in ...
FSGM300N Green-Mode Fairchild Power Switch (FPS™)
... FSGM300N has overload protection, it is not enough to protect the FSGM300N in that abnormal case; since severe current stress is imposed on the SenseFET until OLP is triggered. The FSGM300N internal AOCP circuit is shown in Figure 21. When the gate turn-on signal is applied to the power SenseFET, th ...
... FSGM300N has overload protection, it is not enough to protect the FSGM300N in that abnormal case; since severe current stress is imposed on the SenseFET until OLP is triggered. The FSGM300N internal AOCP circuit is shown in Figure 21. When the gate turn-on signal is applied to the power SenseFET, th ...
APN0010 - GM International srl
... Connect the decade resistor “Rx” at the input terminal as indicate in the diagram (one channel testing). Set the decade at 10 KΩ to simulate a proximity open condition, the indication LED on unit and output LED on terminal block must be relevant with the dip-switch setting indicated in the installat ...
... Connect the decade resistor “Rx” at the input terminal as indicate in the diagram (one channel testing). Set the decade at 10 KΩ to simulate a proximity open condition, the indication LED on unit and output LED on terminal block must be relevant with the dip-switch setting indicated in the installat ...
Velleman_Function_Generator
... labeled Amplitude and type in the value of the DC voltage. It is only allowed to be a number between 0.2 V to 5 V. The position of the line in the graph will change as soon as the function generator begins to output the DC signal with the amplitude that you entered. You do not have to click on Run. ...
... labeled Amplitude and type in the value of the DC voltage. It is only allowed to be a number between 0.2 V to 5 V. The position of the line in the graph will change as soon as the function generator begins to output the DC signal with the amplitude that you entered. You do not have to click on Run. ...
UCC29002 数据资料 dataSheet 下载
... start up and adjust logic The start up and adjust logic responds to unusual operating conditions during start up, fault and disable. Under these circumstances the information obtainable by the error amplifier of the UCC39002 is not sufficient to make the right output voltage adjustment, therefore th ...
... start up and adjust logic The start up and adjust logic responds to unusual operating conditions during start up, fault and disable. Under these circumstances the information obtainable by the error amplifier of the UCC39002 is not sufficient to make the right output voltage adjustment, therefore th ...
8-Channel RC RX MUX User`s Manual
... The 8 Channel RC RX MUX can be used with standard hobby radio control systems and servo controllers to allow easy switching of servo control between two signal sources using a 8th channel of Input A as the output selector. Signal sources can come from R/C receiver, autopilot or microcontroller that ...
... The 8 Channel RC RX MUX can be used with standard hobby radio control systems and servo controllers to allow easy switching of servo control between two signal sources using a 8th channel of Input A as the output selector. Signal sources can come from R/C receiver, autopilot or microcontroller that ...
Tender No.: 07/SPS/EE/2016 Dated
... (1) Sealed tenders are invited for the procurement of laboratory items of HBTI Kanpur. The tender documents can be bought from the Store Purchase Section, Harcourt Butler Technological Institute Kanpur. Interested tenderers may download the same from the website and submit their offer along with Ten ...
... (1) Sealed tenders are invited for the procurement of laboratory items of HBTI Kanpur. The tender documents can be bought from the Store Purchase Section, Harcourt Butler Technological Institute Kanpur. Interested tenderers may download the same from the website and submit their offer along with Ten ...
(a) Results based on the measurements on the circuit in Figure 3(a)
... measuring the open-circuit voltage between terminals X and Y when the resistor RL is removed. RTH is called the Thevenin equivalent resistance and ZTH is called the Thevenin equivalent impedance. By measuring the short-circuit current ISC flowing through a wire that connects X to Y, the value of RTH ...
... measuring the open-circuit voltage between terminals X and Y when the resistor RL is removed. RTH is called the Thevenin equivalent resistance and ZTH is called the Thevenin equivalent impedance. By measuring the short-circuit current ISC flowing through a wire that connects X to Y, the value of RTH ...
MCOTS-C-28-24-HZ-NM - SynQor, Inc.
... increase the output voltage to maintain a constant output current. If this results in the output voltage exceeding the “Output OverVoltage Protection” threshold*, then the unit will shut down. Output Over-Voltage Limit: If the voltage across the output pins exceeds the Output Over-Voltage Protection ...
... increase the output voltage to maintain a constant output current. If this results in the output voltage exceeding the “Output OverVoltage Protection” threshold*, then the unit will shut down. Output Over-Voltage Limit: If the voltage across the output pins exceeds the Output Over-Voltage Protection ...
Chapter 20 (Electricity) Practice Test
... 46. In Figure 20-2, what device could be added to the circuits to open the circuits? Explain how this device works. Compare this device to safety devices that stop the current in a home. ...
... 46. In Figure 20-2, what device could be added to the circuits to open the circuits? Explain how this device works. Compare this device to safety devices that stop the current in a home. ...
CS1101: Lab 2 – Using Structs to Build Filters and Amplifiers
... where extremely sensitive signals are present. Therefore, amplifiers and filters are usually found together in a system. In this lab, we will be creating amplifiers and filters using structures in Scheme. ...
... where extremely sensitive signals are present. Therefore, amplifiers and filters are usually found together in a system. In this lab, we will be creating amplifiers and filters using structures in Scheme. ...
LTC6403-1 - 200MHz, Low Noise, Low Power Fully Differential Input
... voltage offset. Common mode power supply rejection (PSRRCM) is defined as the ratio of the change in supply voltage to the change in the common mode offset, VOUTCM – VOCM. Note 10: Output swings are measured as differences between the output and the respective power supply rail. Note 11: Extended ope ...
... voltage offset. Common mode power supply rejection (PSRRCM) is defined as the ratio of the change in supply voltage to the change in the common mode offset, VOUTCM – VOCM. Note 10: Output swings are measured as differences between the output and the respective power supply rail. Note 11: Extended ope ...
Application Note No. 066
... For some LED applications, including fixed or “architectural” displays, voltages greater than the 18 V maximum rating (pin 3) of the BCR402R may be encountered. For example +24 V is frequently used in so-called architectural display. This section describes the advantages of using BCR402R in such sys ...
... For some LED applications, including fixed or “architectural” displays, voltages greater than the 18 V maximum rating (pin 3) of the BCR402R may be encountered. For example +24 V is frequently used in so-called architectural display. This section describes the advantages of using BCR402R in such sys ...
Operational amplifier

An operational amplifier (""op-amp"") is a DC-coupled high-gain electronic voltage amplifier with a differential input and, usually, a single-ended output. In this configuration, an op-amp produces an output potential (relative to circuit ground) that is typically hundreds of thousands of times larger than the potential difference between its input terminals.Operational amplifiers had their origins in analog computers, where they were used to do mathematical operations in many linear, non-linear and frequency-dependent circuits. The popularity of the op-amp as a building block in analog circuits is due to its versatility. Due to negative feedback, the characteristics of an op-amp circuit, its gain, input and output impedance, bandwidth etc. are determined by external components and have little dependence on temperature coefficients or manufacturing variations in the op-amp itself.Op-amps are among the most widely used electronic devices today, being used in a vast array of consumer, industrial, and scientific devices. Many standard IC op-amps cost only a few cents in moderate production volume; however some integrated or hybrid operational amplifiers with special performance specifications may cost over $100 US in small quantities. Op-amps may be packaged as components, or used as elements of more complex integrated circuits.The op-amp is one type of differential amplifier. Other types of differential amplifier include the fully differential amplifier (similar to the op-amp, but with two outputs), the instrumentation amplifier (usually built from three op-amps), the isolation amplifier (similar to the instrumentation amplifier, but with tolerance to common-mode voltages that would destroy an ordinary op-amp), and negative feedback amplifier (usually built from one or more op-amps and a resistive feedback network).