• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Distribution systems
Distribution systems

... (i) It is possible, in practice, to construct large high-speed a.c. generators of capacities up to 500 MW. Such generators are economical both in the matter of cost per kWh of electric energy produced as well as in operation. Unfortunately, d.c. generators cannot be built of ratings higher than 5 MW ...
Crompton Instruments Integra Ci3 Digital Metering System
Crompton Instruments Integra Ci3 Digital Metering System

... The Integra Ci3 digital metering system (dms) represents the first model of a new generation of digital metering systems designed to complement the current Crompton Instruments Integra series. The Integra Ci3 meter is an accurate and cost effective solution for measurement and display of all major e ...
Types of electrical injuries
Types of electrical injuries

... worker without endangering yourself. Turn off the power or use insulated material to remove the source of contact (low-voltage only). • With high voltage, stay back at least 10 metres (33 ft.) until the owner of the power system says it is safe to approach. Do not become a second victim. If the volt ...
AE4301167171
AE4301167171

... terms of space reductions and performance .FACTS are a result of the development in the power electronics area and aim to rapidly control electrical signals [13]. 2007Losses in distribution transformers account for almost one third of overall transmission and distribution losses [4]. 2008The precise ...
Electrical safety
Electrical safety

... homes in England and Wales became subject to the Building Regulations. Similar requirements are in force in Scotland. The intention of the regulations is to improve the general safety standard of domestic electrical installation work. To reduce the risk of danger, it is important that any electrical ...
Electrical Safety Related Work Practices
Electrical Safety Related Work Practices

... Only use factory-assembled cord sets (Molded Plug). Use only extension cords that have a ground wire (3wire type). Use only extension cords that are marked with a designation code S, ST, SO, and STO for hard service, and SJ, SJO, SJT, and SJTO for junior hard service. Use only cords, connection devi ...
The Principles Of Dimming Leading edge dimming ? Triac
The Principles Of Dimming Leading edge dimming ? Triac

... will be specified for a purpose. Often this purpose will need a lot of light but may be too much at other times. This is nothing new, candle lamps used mechanical screens and oil lamps adjustable wicks. Aesthetic, artistic, mood setting, visual comfort, or energy saving are all valid reasons for cha ...
Do You Know Where Your Fault Currents are Flowing?
Do You Know Where Your Fault Currents are Flowing?

... Two of the buildings contain two 1,500 kVA transformers that step down the voltage from 12,470 to 480 Volts. The third building has only one transformer. The campus is fed by a main S&C Vista Switch. The Vista Switch has a solid state electronic trip unit set to trip on phase and ground faults. The ...
III. UPQC - Academic Science,International Journal of Computer
III. UPQC - Academic Science,International Journal of Computer

... quality issues. To improve upon certain problems observed, one of the customer power devices called UPQC is mentioned. UPQC consist of combine series active filter and shunt active filter. The former compensates voltage harmonics and the latter will compensate harmonic currents of non-linear load. T ...
Linear Systems Offers Direct Alternative for Analog Devices MAT01
Linear Systems Offers Direct Alternative for Analog Devices MAT01

... Notes:  1. Absolute Maximum ratings are limiting values above which serviceability may be impaired 2. The reverse base‐to‐emitter voltage must never exceed 6.2 volts; the reverse base‐to‐emitter current must never exceed 10µA.  ...
SINGLE-WIRE ELECTRIC POWER SYSTEM FOR RENEWABLE
SINGLE-WIRE ELECTRIC POWER SYSTEM FOR RENEWABLE

... Abstract – Low cost and low losses single-wire electric power system (SWEPS) for renewable- based electric grid was developed. The new technology of electric power transmission uses idle operation regime of the transmission line and reactive capacitive current for transmission of active electric pow ...
Transmission of electrical power
Transmission of electrical power

... both of which are set up by Faraday’s law due to the magnetic flux change that is part of AC circuits. Both of these currents produce I2R heat loss. Hysteresis losses are less significant than eddy losses. Recall from Topic 12.2 that eddy currents can be minimized by lamination of the transformer c ...
Electric current is measured in units called amps
Electric current is measured in units called amps

... Electric current is measured in units called amps (A). The electric current is not used up by the components in a circuit but it transfers energy from the voltage source to the various components making up the circuit. Electric current is measured using an ammeter. ...
Lab 2
Lab 2

... Since the Series connection has an HV output of 120.0, in parallel the 2 outputs should be half as much, i.e. 60.0 Vac each. C. Open-Circuit Test Object: To perform measurements on the transformer under open-circuit (no-load) conditions; to measure the core losses and the excitation current; to use ...
RGB LED Color Controller
RGB LED Color Controller

... With longer lengths of RGB LED tape lighting, voltage drop also occurs within the tape light. Voltage drop only becomes undesirable if you notice the light color or brightness in one area of your lighting is objectionably different than another area. As a practical approach to installing your RGB LE ...
Application Note: XIM Distributed Low Voltage Design
Application Note: XIM Distributed Low Voltage Design

... rating due to its power limitations, and is considered safe, from a fire and electrical shock standpoint. UL 1598 applies to luminaires for use in non-hazardous locations that are intended for installation on branch circuits of 600V or less. Note that UL 1598 could be applied to a complete piece of ...
PQ Overview – Practical Aspect
PQ Overview – Practical Aspect

... installed at 220kV bus of one of the transmission stations of MTB to monitor grid voltage. Any dip exceeding 10% is instantly captured. The readings are downloaded every month, analysed and a report is generated every month. Sample report for 220kV monitoring is shown in Tables 1 & 2. Similar report ...
ELECTRICIAN - ELTR
ELECTRICIAN - ELTR

... ABCWUA Position Description ELECTRICIAN Status APPROVED ...
Cushion Pack© CP 430 S2+ Cardboard Shredder Electrical
Cushion Pack© CP 430 S2+ Cardboard Shredder Electrical

... When you use higher voltage, less current is required. To use a water hose analogy, the electrical current is the water pressure and the voltage is the diameter of the hose – the bigger the hose the less pressure is required to deliver the same amount of water. This means that you can use thinner ga ...
Electrical Safe Working Practices
Electrical Safe Working Practices

... Example, control wiring in a large mechanical services switchboard. ...
I consumer
I consumer

... by the usage of welding device, containing controlled electric arc, protection does not function, i. e. have to be blocked microwave has the fifth harmonic of 45.5 % I5g; the microwave decrease the total fifth harmonic appearing in parallel connection microwave - circuit of resistive load with ele ...
Unit 16* Alternating Current (AC)
Unit 16* Alternating Current (AC)

... • The single greatest advantage of alternating current is that AC current can be transformed and DC current cannot be transformed. • This allows high-voltage electrical power to be distributed with smaller wires and lower amperage. • The electrical power is then transformed to a lower voltage where ...
Unit 16 Alternating Current
Unit 16 Alternating Current

... The single greatest advantage of alternating current is that AC current can be transformed and DC current cannot be transformed. This allows high-voltage electrical power to be distributed with smaller wires and lower amperage. The electrical power is then transformed to a lower voltage where it is ...
Lesson 15. Grammar material: Prepositions. Text: “Transformers
Lesson 15. Grammar material: Prepositions. Text: “Transformers

... Although there are many different types of transformers and a great variety of different applications, the principles of action are the same in each case. The transformer is a device for changing the electric current from one voltage to another. It is used for increasing or decreasing voltage. So th ...
TRANSFORMER TYPES Potential Transformers
TRANSFORMER TYPES Potential Transformers

... various voltage, frequency and physical size ranges. We have broken them up into several different groupings: low voltage, which are system voltages under 15kV; high frequency, operating frequency over 1kHz; and size ranges from board mount parts up to current transformers with window sizes of 254mm ...
< 1 ... 27 28 29 30 31 32 33 34 35 ... 50 >

War of the currents

  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report