• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
179. Under Voltage Load Shedding Scheme to Provide Voltage
179. Under Voltage Load Shedding Scheme to Provide Voltage

... Energy, Environment and Sustainable Development 2016 (EESD 2016) loads. In many researches the load shedding problem is studied from steady state point of view. In [8] a steady state load shedding scheme based on Genetic Algorithm (GA) method is proposed which considers operational constraints. The ...
03_Environment
03_Environment

... service for a new generating source that is planned to be interconnected with a TSP's transmission network, the transmission service customer shall be responsible for the cost of installing step-up transformers to transform the output of the generator to a transmission voltage level and protective d ...
FINAL SAFETY ANALYSIS REPORT CHAPTER 8 ELECTRIC POWER BBNPP
FINAL SAFETY ANALYSIS REPORT CHAPTER 8 ELECTRIC POWER BBNPP

... BBNPP transmission lines will utilize one new on-site corridor and the on-site SusquehannaRoseland corridor for interconnections to the existing offsite power transmission grid as shown in Figure 8.2-1. The two circuits are supported on separate structures, which are located to minimize the likeliho ...
Task A. Transmission Line and Discontinuities
Task A. Transmission Line and Discontinuities

Application of SVCs by CenterPoint Energy to Address Voltage
Application of SVCs by CenterPoint Energy to Address Voltage

HN3613321337
HN3613321337

FUZZY LOGIC BASED CONTINGENCY ANALYSIS
FUZZY LOGIC BASED CONTINGENCY ANALYSIS

... There are number of methods for evaluating of contingency of power system i.e., conventional load flows, neural networks, fuzzy based etc. Load flow is important part of the contingency analysis. Work is carried out on the topics which consists of the potential contingencies cases by using ranking m ...


reactive power and voltage control issues in electric
reactive power and voltage control issues in electric

final_report - An-Najah National University
final_report - An-Najah National University

Slajd 1
Slajd 1

Impedance Part 1 File
Impedance Part 1 File

... Assuming an operating frequency of 50 MHz, one wavelength is: λ = 300/fMHz = 300/50 = 6 meters or about 20 feet λ/4 = 20/4 = 5 feet Assuming the use of 52-Ω RG-8/U coax transmission line with a velocity factor of 0.66: λ/4 = 5 feet (0.66) = 3.3 feet Several important limitations should be considered ...
Protection of Transmission System Using Global Positioning System
Protection of Transmission System Using Global Positioning System

... The accuracy of fault location depends on the ability to accurately time tagging the arrival of the traveling wave at each line terminal. The traveling wave once generated, is subject to attenuation and distortion as it propagates along the transmission line. Attenuation occurs due to resistive and ...
Principles of Electronic Communication Systems
Principles of Electronic Communication Systems

Per Phase Analysis
Per Phase Analysis

Slides
Slides

... Transmission constraints can segment a market, resulting in differing LMP Determination of LMPs requires the solution on an Optimal Power Flow (OPF) ...
Diagnosing transmission control
Diagnosing transmission control

... Diagnosing Transmission Control ...
Chapter 8 Electrical Power 8.1 Introduction
Chapter 8 Electrical Power 8.1 Introduction

A Review Paper on Icing and Methods to De
A Review Paper on Icing and Methods to De

Analysing of a Shunt Compensator Installation
Analysing of a Shunt Compensator Installation

... used are of the inductive type. Inductive loads when connected to the power system will cause induction to occur and this will make the power factor to drop. In order to overcome this problem, we need to install a capacitor which is commonly known as compensator to make the power factor correction.C ...
Most Common Errors in Service Entrance and Load Side Install
Most Common Errors in Service Entrance and Load Side Install

... lighting service. ...
F42012733
F42012733

PowerPoint Sunusu
PowerPoint Sunusu

... If the termination resistor RT is equal to the characteristic impedance of the transmission line, then the transmitted signal will not reflect at all. The energy associated with the currents and voltages propagating along the transmission line is completely dissipated by the termination resistor. As ...
Chapter 8 Electrical Power 8.1 Introduction
Chapter 8 Electrical Power 8.1 Introduction

UNIT PART-A 1.  What is communication and mention the three essential... communication?
UNIT PART-A 1. What is communication and mention the three essential... communication?

< 1 ... 6 7 8 9 10 11 12 13 14 ... 35 >

Electric power transmission



Electric power transmission is the bulk transfer of electrical energy, from generating power plants to electrical substations located near demand centers. This is distinct from the local wiring between high-voltage substations and customers, which is typically referred to as electric power distribution. Transmission lines, when interconnected with each other, become transmission networks. The combined transmission and distribution network is known as the ""power grid"" in North America, or just ""the grid"". In the United Kingdom, the network is known as the ""National Grid"".A wide area synchronous grid, also known as an ""interconnection"" in North America, directly connects a large number of generators delivering AC power with the same relative frequency, to a large number of consumers. For example, there are four major interconnections in North America (the Western Interconnection, the Eastern Interconnection, the Quebec Interconnection and the Electric Reliability Council of Texas (ERCOT) grid), and one large grid for most of continental Europe.The same relative frequency, but almost never the same relative phase as ac power interchange is a function of the phase difference between any two nodes in the network, and zero degrees difference means no power is interchanged; any phase difference up to 90 degrees is stable by the ""equal area criteria""; any phase difference above 90 degrees is absolutely unstable; the interchange partners are responsible for maintaining frequency as close to the utility frequency as is practical, and the phase differences between any two nodes significantly less than 90 degrees; should 90 degrees be exceeded, a system separation is executed, and remains separated until the trouble has been corrected.Historically, transmission and distribution lines were owned by the same company, but starting in the 1990s, many countries have liberalized the regulation of the electricity market in ways that have led to the separation of the electricity transmission business from the distribution business.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report