• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Enter o to this page the details for the document
Enter o to this page the details for the document

... We used a large flat coil of 500 turns around a 10 cm diameter former. The depth of the coil was 2 cm. Other coils such as coils from demountable transformers and intact coils from discarded ticker timers can be used, and work well. They may require some form of a guide to get the magnet through the ...
Rotary Switch Basics - Electroswitch Electronic Products
Rotary Switch Basics - Electroswitch Electronic Products

All about Digital Input and Digital Output
All about Digital Input and Digital Output

G7J-2A2B-B DC12 Datasheet
G7J-2A2B-B DC12 Datasheet

... 2. The contact resistance was measured with 1 A at 5 VDC using the voltage drop method. 3. The operate and the release times were measured with the rated voltage imposed with any contact bounce ignored at an ambient temperature of 23°C. 4. The insulation resistance was measured with a 500-VDC megger ...
Current Transformers Ratio / Polarity / Types
Current Transformers Ratio / Polarity / Types

... flux (field) produced by the current flow through the primary (usually one-turn) results in an output voltage which is balanced by an equal and opposite output from the control or measuring circuit. Because the circuit is an amplifier, it requires external operating power which is supplied by the co ...
Yardmaster Pup™ Magnet Controller 4292P
Yardmaster Pup™ Magnet Controller 4292P

Installation and Maintenance Sheet - IF 1405 Revision 1
Installation and Maintenance Sheet - IF 1405 Revision 1

... 4. Install proper rated cartridge fuses (not included with enclosure) in fusible type safety switches. WSRD fusible safety switches are factory-set for Class H fuses and are rated to withstand 10,000 amps RMS symmetrical. 5. Test wiring for correctness with continuity checks and for unwanted grounds ...
Analog Photosensor Installation Instructions (when used with Daylighting Controller)
Analog Photosensor Installation Instructions (when used with Daylighting Controller)

... footcandle level than the OFF setpoint. This way, the controlled lights will not switch OFF during a period when they should be ON. The difference between the ON and OFF setpoints is called the Deadband. In general, the deadband should be large enough (about 10% of the expected calibration range) to ...
Line Protection with Overcurrent Relays
Line Protection with Overcurrent Relays

... against interphase faults and a separate overcurrent relay for single-phase-to-ground faults. Separate ground relays are generally favored because they can be adjusted to provide faster and more sensitive protection for single-phase-to-ground faults than the phase relays can provide. However, the ph ...
doduco lieferspektrum englisch 5-2011.cdr
doduco lieferspektrum englisch 5-2011.cdr

2014 SERC SOC_ProtectiveRelayRefresher_SOC3_SOC4
2014 SERC SOC_ProtectiveRelayRefresher_SOC3_SOC4

Microfabrication is about to revolutionize the way reed switches are
Microfabrication is about to revolutionize the way reed switches are

Model Number Structure Ordering Information
Model Number Structure Ordering Information

... Note: 1. Do not use the output from an inverter as the power supply. Refer to Safety Precautions for All Times for details. 2. Single-phase, full-wave-rectified power supplies can be used. 3. When using the H3YN continuously in any place where the ambient temperature is in a range of 45°C to 50°C, s ...
Datasheet
Datasheet

starting system
starting system

... •Has an extra gear on the armature to further increase the rotating force •Gear ratio between flywheel and armature is 45:1 •Hence, the armature turns 45 times to turn the flywheel (engine) once. •This provides high cranking torque for starting. ...
Extending the MFJ-927 to 160-Meters
Extending the MFJ-927 to 160-Meters

... In the “Reviews” section of this website I reviewed the CG-3000, MFJ-927, and the SG230 auto-tuners specifically for use with the popular 43-foot vertical antenna. As discussed in that review only the SG-230 had enough internal inductance to tune the 43foot vertical on 160 meters, so I described an ...
Protection and Commissioning of Multifunction Digital Transformer
Protection and Commissioning of Multifunction Digital Transformer

Aalborg Universitet Margin against Cascading Events
Aalborg Universitet Margin against Cascading Events

... [2-6]. Among the diverse countermeasures, load shedding is regarded as the last and fast resort when there is no other alternative to adjust the system emergent states and stop the progress approaching voltage collapse [4] [7] [8]. In this paper, a sensitivity based load shedding strategy is propose ...
Installation Guide for Gentex GN
Installation Guide for Gentex GN

Stakeholder Comparison Comment Rationale Matrix 2010-07-15 AESO AUTHORITATIVE DOCUMENT PROCESS
Stakeholder Comparison Comment Rationale Matrix 2010-07-15 AESO AUTHORITATIVE DOCUMENT PROCESS

... Owner, and Distribution Provider shall evaluate relay loadability at 0.85 per unit voltage and a power factor angle of 30 degrees: [Violation Risk Factor: High] [Mitigation Time Horizon: Long Term Planning]. R1.1. Set transmission line relays so they do not operate at or below 150% of the highest se ...
Stakeholder Comparison Comment Rationale Matrix 2010-07-15 AESO AUTHORITATIVE DOCUMENT PROCESS
Stakeholder Comparison Comment Rationale Matrix 2010-07-15 AESO AUTHORITATIVE DOCUMENT PROCESS

... expressed in amperes; R1.3. Set transmission line relays so they do not operate at or below 115% of the maximum theoretical power transfer capability (using a 90-degree angle between the sending-end and receiving-end voltages and either reactance or complex impedance) of the transmission line expres ...
Class-A Trip
Class-A Trip

Model 98-Z - PlasmaCAM
Model 98-Z - PlasmaCAM

Modifying the exterior lighting of the Ram truck Use of LED lamps in
Modifying the exterior lighting of the Ram truck Use of LED lamps in

... Adding additional incandescent lamps to the original equipment incandescent lamps: Customers sometimes desire to add additional lamps to the exterior lighting circuits. This is possible but requires adding a relay to control the additional lamps. By correctly wiring the relay into the lighting circu ...
Mazda 626 GE 2.0 FS
Mazda 626 GE 2.0 FS

< 1 ... 20 21 22 23 24 25 26 27 28 ... 65 >

Relay



A relay is an electrically operated switch. Many relays use an electromagnet to mechanically operate a switch, but other operating principles are also used, such as solid-state relays. Relays are used where it is necessary to control a circuit by a low-power signal (with complete electrical isolation between control and controlled circuits), or where several circuits must be controlled by one signal. The first relays were used in long distance telegraph circuits as amplifiers: they repeated the signal coming in from one circuit and re-transmitted it on another circuit. Relays were used extensively in telephone exchanges and early computers to perform logical operations.A type of relay that can handle the high power required to directly control an electric motor or other loads is called a contactor. Solid-state relays control power circuits with no moving parts, instead using a semiconductor device to perform switching. Relays with calibrated operating characteristics and sometimes multiple operating coils are used to protect electrical circuits from overload or faults; in modern electric power systems these functions are performed by digital instruments still called ""protective relays"".
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report