• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Relative Dipolar Behavior of the Equivalent T Wave Generator
Relative Dipolar Behavior of the Equivalent T Wave Generator

... the relatively small amount of T locus dispersion. Of greater interest, however, are the contrasting observations that (1) there is considerable movement of equivalent dipole location between the beginning and end of ventricular depolarization, whereas (2) there is relatively little movement of the ...
12 Lead ECGs: Ischemia, Injury, Infarction
12 Lead ECGs: Ischemia, Injury, Infarction

...  Go on a “Q wave search”  Are the Q waves ≤ .04 seconds wide and ≤ 25% the height of the R wave? You might see small Q waves in Lead II, III, aVF, V5, and V6. These identified Q waves meet the “normal” criteria & simply record that the septum had normal depolarization.  Go on an “R wave search”  ...
Tetralogy of Fallot
Tetralogy of Fallot

... What other tests should we consider? There is a chance that there are other heart defects and organ abnormalities so it is important to check the baby for other problems. Further tests include a detailed ultrasound that is used to assess the baby’s other organs. A fetal echocardiogram, which is a de ...
Disease/Disorders of the Heart
Disease/Disorders of the Heart

... properly, causing your heart to beat too fast, too slow or irregularly. Heart arrhythmias (uh-RITH-me-uhs) may feel like a fluttering or racing heart and may be harmless. However, some heart arrhythmias may cause bothersome — sometimes even lifethreatening — signs and symptoms. Heart arrhythmia trea ...
Acute Myocardial Infarction (AMI) - Mountain
Acute Myocardial Infarction (AMI) - Mountain

... Guidelines recommend patients presenting with chest discomfort or symptoms suggestive of ST-segment elevation myocardial infarction (STEMI) have a 12-lead electrocardiogram (ECG) performed within a target of 10 minutes of emergency department arrival. ...
Mathematical Modeling of Electrocardiograms: A Numerical Study
Mathematical Modeling of Electrocardiograms: A Numerical Study

... first, provide realistic simulations of the 12-lead ECG based on a complete PDE model with a fully coupled heart–torso formulation; second, discuss through numerical simulations the impact of various modeling options and the sensitivity to the model parameters. Note that the achievement of these two ...
Electrocardiography for Healthcare Professionals Chapter 8: Heart
Electrocardiography for Healthcare Professionals Chapter 8: Heart

... -referred to as complete heart block (CHB) -all impulses above the ventricles are blocked and cannot reach the ventricles -no correlation between atrial and ventricular depolarization -P-P and R-R intervals are firing at different rates ...
Document
Document

... beat in a more coordinated and synchronized manner, thus more effectively. Studies have shown that around one-third of patients with advanced heart failure do not effectively respond to cardiac ...
05 Heart Rate Response LQ
05 Heart Rate Response LQ

... squatting position. Maintain this position until your heart rate returns to the initial baseline rate. 7. After obtaining 10–20 s of stable heart rate values, rise rapidly to a standing position. Continue to record data until the baseline heart rate has been achieved, or until the end of the run. Da ...
VAI TRÒ CỦA CHỤP CẮT LỚP VI TÍNH 64 LÁT TRONG CHẨN
VAI TRÒ CỦA CHỤP CẮT LỚP VI TÍNH 64 LÁT TRONG CHẨN

... . Improves both spatial and temporal resolution. . Increases scanning speed. . Improves diagnostic image quality by reducing respiratory artifacts R. C. Gilkeson1, Leslie Ciancibello1 and Kenneth Zahka2. Multidetector CT Evaluation of Congenital Heart Disease in Pediatric and Adult Patients ...
Heart rate variability in the course of ST
Heart rate variability in the course of ST

... physical activity on HR and HRV was limited due to in-hospital settings and restricted to a rehabilitation programme what eliminates the remarkable impact of exercise on the autonomic nervous system [14]. In the guidelines of the European Society of Cardiology on the management of acute myocardial i ...
Cardiology
Cardiology

... Fred Kusumoto ...
Outline 4
Outline 4

... enters Right Atrium b. Self-excites faster than other nodal cells 3. Atrioventricular (AV) node a. Located in the lower medial floor of right atrium b. Slows Conduction Velocity (100 msec) 1) Allows time for Atria to contract 4. Atrioventricular (AV) bundle – Bundle of His a. Located in the Interven ...
Chapter 14
Chapter 14

... by the pressure inside the chest. The output of the heart is reduced and stroke volume falls. This occurs from 5 to about 14 seconds in the illustration. The fall in stroke volume reflexively causes blood vessels to constrict with some rise in pressure (15 to 20 seconds). This compensation can be qu ...
Document
Document

... Characterized by primary decrease in ventricular compliance, resulting in impaired ventricular filling during diastole. • It is the least common type of Cardiomyopathy. • The problem is a stiff and inelastic ventricle that can be filled only with great effort. • Myocardial contractility, although of ...
Poster and Podium Instructions for Power Point
Poster and Podium Instructions for Power Point

... clinical trial which was included in this systematic review. To find more articles, the first clinical trials’ primary author G.M. Wieselthaler was searched which resulted in 19 articles. Of these articles only two were clinical trials on the HeartWare Ventricular Assist System, one was the first cl ...
Sunshine Heart Implants First Patient in C
Sunshine Heart Implants First Patient in C

... participating in the COUNTER HF pivotal study. The C-Pulse system, in comparison to other devices used for circulatory support, offers the advantage of implantation through a truly minimally invasive approach without the need for cardiopulmonary bypass or sternal division. Its non-blood contacting i ...
Daphnia heart rate conclusion sample
Daphnia heart rate conclusion sample

... more caffeine in the water, the higher the heart rate of the Daphnia went. When the Daphnia was in water that had only 18mg of caffeine, the heart rate increased very little from the control But when the amount of caffeine was increased to 80mg, the heart rate increased about 30 beats per minute com ...
Notes on Residuals
Notes on Residuals

Pediatric Cardiac Emergencies
Pediatric Cardiac Emergencies

... • prolonged loss of consciousness • associated chest pain or palpitations • medications that can alter cardiac conduction ...
cardiac rhythm devices: pacemakers, ilr, icd, crt
cardiac rhythm devices: pacemakers, ilr, icd, crt

... C. Second Degree AV Block, Wenckebach D.Second Degree AV Block, Mobitz E. Third Degree AV Block ...
Junctional rhythm
Junctional rhythm

... cycle of a rhythm initiated by a higher pacemaker when the rate of the dominant pacemaker becomes less than the rate of the AV node. The junction can “escape in” when the electrical impulses of the SA node fail to reach the AV node within 1 to 1½ seconds as in the following: a. ...
Ventricular hypertrophy icd 10
Ventricular hypertrophy icd 10

... Ventricular hypertrophy icd 10 Ventricular hypertrophy icd 10 Ventricular tachycardia is a fast heart rhythm that starts in the lower part of the heart (ventricles). If left untreated, some forms of ventricular tachycardia may. Aneurysm of heart; Heart left ventricular aneurysm short axis view: Clas ...
Raymond Plank Makes Transformational Gift for
Raymond Plank Makes Transformational Gift for

... include: investigational pharmacology for improvement of heart function and the use of left ventricular assist devices in heart failure patients. Q: A friend was recently diagnosed with heart failure. What does this mean? A: Despite the way it sounds, heart failure does not mean that the heart has s ...
CT appearance of isolated dextroversion
CT appearance of isolated dextroversion

... ventricle remain to the right, they are located posterior to the corresponding left sided chambers. It is as if, looking from below, the normal heart is rotated counterclockwise to the patient’s right on an axis passing through the right atrium. In the less common form of dextroversion, an ...
< 1 ... 477 478 479 480 481 482 483 484 485 ... 762 >

Electrocardiography



Electrocardiography (ECG or EKG*) is the process of recording the electrical activity of the heart over a period of time using electrodes placed on a patient's body. These electrodes detect the tiny electrical changes on the skin that arise from the heart muscle depolarizing during each heartbeat.In a conventional 12 lead ECG, ten electrodes are placed on the patient's limbs and on the surface of the chest. The overall magnitude of the heart's electrical potential is then measured from twelve different angles (""leads"") and is recorded over a period of time (usually 10 seconds). In this way, the overall magnitude and direction of the heart's electrical depolarization is captured at each moment throughout the cardiac cycle. The graph of voltage versus time produced by this noninvasive medical procedure is referred to as an electrocardiogram (abbreviated ECG or EKG).During each heartbeat, a healthy heart will have an orderly progression of depolarization that starts with pacemaker cells in the sinoatrial node, spreads out through the atrium, passes through the atrioventricular node down into the bundle of His and into the Purkinje fibers spreading down and to the left throughout the ventricles. This orderly pattern of depolarization gives rise to the characteristic ECG tracing. To the trained clinician, an ECG conveys a large amount of information about the structure of the heart and the function of its electrical conduction system. Among other things, an ECG can be used to measure the rate and rhythm of heartbeats, the size and position of the heart chambers, the presence of any damage to the heart's muscle cells or conduction system, the effects of cardiac drugs, and the function of implanted pacemakers.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report