• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Document
Document

... 2-The power and reactive power generated at the slack bus and the reactive power generated at the P-V bus are unknown. Since we do not need these quantities for our load flow calculations, their initial estimates are not required 3-the slack bus does not contain any load while the P-V bus 5 has a lo ...
Enhancement of Power Quality in Distribution System Using D
Enhancement of Power Quality in Distribution System Using D

... problem by Electromagnetic interference noise’s misgating–on is major killer to the inverter reliability. Dead time to block both upper and lower devices has to provide in the Voltage Source Inverter which causes the waveform distortion, etc. An output LC filters needed for providing a sinusoidal vo ...
S03 Editors Report - Raleigh
S03 Editors Report - Raleigh

... Transaction Papers on transformers, please sign up at: http://tpwrd-ieee.manuscriptcentral.com/ INSTRUCTIONS FOR SIGNING UP TO REVIEW IEEE TRANSACTIONS PAPERS 1. Before you create a new account, please check for an existing account by clicking on: "Check for Existing Account" 2. Assuming that you do ...
Current Amplifier
Current Amplifier

... switched current amplifier designated CA3™ solves this problem. It can provide 3 x 30 A or 1 x 60 A connected in parallel. Maximum output power is 600 VA (3 x 25 A at 8 V). If higher voltage is needed, you can make the connection between two phases (L-L). If you need even higher current, two or more ...
Download T2100 Datasheet
Download T2100 Datasheet

... The T2100 calculates I x sin φ, representing the reactive power. If the reactive power becomes negative and exceeds the preset level (0.5-1.5 x IN), the pickup LED will indicate and the delay timer will be started. After the preset time (2-20 sec.) has expired, the output relay and LED will be activ ...
T11UM GENERAL CHARACTERISTICS
T11UM GENERAL CHARACTERISTICS

P Series Data Sheet
P Series Data Sheet

... EDGE-OF-THE-ART MULTI-MONO DESIGN By design, P2 and P5 amplifiers are powerful independent “monoblock” amplifiers. Each channel is self-contained on its own glass-epoxy circuit board and heatsink and benefits from an independent power supply. Since there is no common audio path between channels ther ...
Nanocrystalline core materials in modern power electronic …
Nanocrystalline core materials in modern power electronic …

... about 1.300°C is sprayed through a narrow ceramic nozzle directly onto a water-cooled, fast-rotating copper roller. At a speed of more than 100 km/h a continuous amorphous ribbon of only approx. 20 µm in thickness is obtained. In other words, more or less in a single step of production, such a thin ...
CMOS Power Dissipation
CMOS Power Dissipation

... Hazard generation can be reduced by gate sizing and path balancing techniques Hazard propagation can be reduced by using less number of inverters which tend to amplify and propagate glitches ...
Stereo 416 and PAT-5 Bifet Brochure, Page 2
Stereo 416 and PAT-5 Bifet Brochure, Page 2

Motor Drivers Stepper and DC Motor Drivers Microchip offers
Motor Drivers Stepper and DC Motor Drivers Microchip offers

... Microchip offers devices to drive bipolar stepper motors, or bidirectional control of two DC motors. These devices are ...
File
File

... connection between two points in a circuit, often causing excess current flow. - current travels along a different path than originally intended. Short circuits may cause: circuit damage, overheating, fire or explosion. ...
Loop and Nodal Analysis and Op Amps
Loop and Nodal Analysis and Op Amps

... Mfiles designed to be functions act as subroutines in the workspace. Parameters are passed into the function and results are passed to the output. Intermediate values do not remain in the work space. Mfiles designed to be scripts are a sequence of Matlab commands that are executed in the order typed ...
Arc Fault Circuit Interrupter Explained
Arc Fault Circuit Interrupter Explained

... breaker. Overload fault circuit interrupters (OFCI) are designed to protect against excess current drawn by utilization equipment. OFCIs must be located within receptacles. Both thermal circuit breakers and OFCIs are required to prevent fire ignition from excess current. High line-voltage creates e ...
Unit 3 Study Design 2009 Motion in one and two dimensions • apply
Unit 3 Study Design 2009 Motion in one and two dimensions • apply

U.S. Department of Energy`s report on Reducing Power Factor Costs
U.S. Department of Energy`s report on Reducing Power Factor Costs

... Real power = 100 kW and Apparent power = 142 kVA then Power Factor = 100/142 = 0.70 or 70%. ...
Smart Panel - Remap Network
Smart Panel - Remap Network

... MAXC ICs and provides all of the sense points and MOSFET drivers required for the critical elements within the design. The power MOSFETs Q1 and Q2 provide dual functionality depending on the DC-POD state of operation. In the ”Connected” state when power-conversion is being performed and the MPPT con ...
ISSCC 2004 / SESSION 12 / BIOMICROSYSTEMS / 12.6 12.6
ISSCC 2004 / SESSION 12 / BIOMICROSYSTEMS / 12.6 12.6

... waveform shown. The required charge may be delivered with less power than is used in a traditional current source if the electrodes are driven with a voltage source which exactly follows the voltage waveform in Fig. 12.6.2. Switching the electrode through a sequence of increasing voltage steps appro ...
AC Power Products Overview
AC Power Products Overview

... Critical Power – Avoid revenue losses caused by extended utility power outages for large industries such as e-commerce, high-speed manufacturing, and broadcast. ...
Lecture notes
Lecture notes

... of materials, such as metals, the outermost electrons in the atoms are so loosely bound that they chaotically move in the space between the atoms of that material by nothing more than the influence of roomtemperature heat energy. In other types of materials such as glass, the atoms' electrons have v ...
AL4201250256
AL4201250256

... parameters, real and reactive powers are calculated. These power system is controlled independently by using transfer functions to derive direct and quadrature axis voltages. These direct axis voltage can control real power and quadrature axis will control the reactive power flow from STATCOM. The t ...
PS4-24 - Juice Goose
PS4-24 - Juice Goose

... This metal enclosure houses the power transformer as well as the power supply circuit board. ...
ac synchronous generators
ac synchronous generators

... Why do we study AC synchronous generators? The short answer is that 3-phase AC generators are the workhorse of the power generation arena. Why? They are not as power limited as DC generators and voltage-level shifting is less expensive using AC (via transformers) rather than DC (power electronics). ...
Deltaweld® Series
Deltaweld® Series

FlexPower Lifts
FlexPower Lifts

< 1 ... 987 988 989 990 991 992 993 994 995 ... 1128 >

Power engineering



Power engineering, also called power systems engineering, is a subfield of energy engineering that deals with the generation, transmission, distribution and utilization of electric power and the electrical devices connected to such systems including generators, motors and transformers. Although much of the field is concerned with the problems of three-phase AC power – the standard for large-scale power transmission and distribution across the modern world – a significant fraction of the field is concerned with the conversion between AC and DC power and the development of specialized power systems such as those used in aircraft or for electric railway networks. It was a subfield of electrical engineering before the emergence of energy engineering.Electricity became a subject of scientific interest in the late 17th century with the work of William Gilbert. Over the next two centuries a number of important discoveries were made including the incandescent light bulb and the voltaic pile. Probably the greatest discovery with respect to power engineering came from Michael Faraday who in 1831 discovered that a change in magnetic flux induces an electromotive force in a loop of wire—a principle known as electromagnetic induction that helps explain how generators and transformers work.In 1881 two electricians built the world's first power station at Godalming in England. The station employed two waterwheels to produce an alternating current that was used to supply seven Siemens arc lamps at 250 volts and thirty-four incandescent lamps at 40 volts. However supply was intermittent and in 1882 Thomas Edison and his company, The Edison Electric Light Company, developed the first steam-powered electric power station on Pearl Street in New York City. The Pearl Street Station consisted of several generators and initially powered around 3,000 lamps for 59 customers. The power station used direct current and operated at a single voltage. Since the direct current power could not be easily transformed to the higher voltages necessary to minimise power loss during transmission, the possible distance between the generators and load was limited to around half-a-mile (800 m).That same year in London Lucien Gaulard and John Dixon Gibbs demonstrated the first transformer suitable for use in a real power system. The practical value of Gaulard and Gibbs' transformer was demonstrated in 1884 at Turin where the transformer was used to light up forty kilometres (25 miles) of railway from a single alternating current generator. Despite the success of the system, the pair made some fundamental mistakes. Perhaps the most serious was connecting the primaries of the transformers in series so that switching one lamp on or off would affect other lamps further down the line. Following the demonstration George Westinghouse, an American entrepreneur, imported a number of the transformers along with a Siemens generator and set his engineers to experimenting with them in the hopes of improving them for use in a commercial power system.One of Westinghouse's engineers, William Stanley, recognised the problem with connecting transformers in series as opposed to parallel and also realised that making the iron core of a transformer a fully enclosed loop would improve the voltage regulation of the secondary winding. Using this knowledge he built a much improved alternating current power system at Great Barrington, Massachusetts in 1886. In 1885 the Italian physicist and electrical engineer Galileo Ferraris demonstrated an induction motor and in 1887 and 1888 the Serbian-American engineer Nikola Tesla filed a range of patents related to power systems including one for a practical two-phase induction motor which Westinghouse licensed for his AC system.By 1890 the power industry had flourished and power companies had built thousands of power systems (both direct and alternating current) in the United States and Europe – these networks were effectively dedicated to providing electric lighting. During this time a fierce rivalry in the US known as the ""War of Currents"" emerged between Edison and Westinghouse over which form of transmission (direct or alternating current) was superior. In 1891, Westinghouse installed the first major power system that was designed to drive an electric motor and not just provide electric lighting. The installation powered a 100 horsepower (75 kW) synchronous motor at Telluride, Colorado with the motor being started by a Tesla induction motor. On the other side of the Atlantic, Oskar von Miller built a 20 kV 176 km three-phase transmission line from Lauffen am Neckar to Frankfurt am Main for the Electrical Engineering Exhibition in Frankfurt. In 1895, after a protracted decision-making process, the Adams No. 1 generating station at Niagara Falls began transmitting three-phase alternating current power to Buffalo at 11 kV. Following completion of the Niagara Falls project, new power systems increasingly chose alternating current as opposed to direct current for electrical transmission.Although the 1880s and 1890s were seminal decades in the field, developments in power engineering continued throughout the 20th and 21st century. In 1936 the first commercial high-voltage direct current (HVDC) line using mercury-arc valves was built between Schenectady and Mechanicville, New York. HVDC had previously been achieved by installing direct current generators in series (a system known as the Thury system) although this suffered from serious reliability issues. In 1957 Siemens demonstrated the first solid-state rectifier (solid-state rectifiers are now the standard for HVDC systems) however it was not until the early 1970s that this technology was used in commercial power systems. In 1959 Westinghouse demonstrated the first circuit breaker that used SF6 as the interrupting medium. SF6 is a far superior dielectric to air and, in recent times, its use has been extended to produce far more compact switching equipment (known as switchgear) and transformers. Many important developments also came from extending innovations in the ICT field to the power engineering field. For example, the development of computers meant load flow studies could be run more efficiently allowing for much better planning of power systems. Advances in information technology and telecommunication also allowed for much better remote control of the power system's switchgear and generators.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report