• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
QX2327862792
QX2327862792

... the latter, shown in Fig. 2(b). In this case, one of the half-bridge circuits can be considered as the reference or master leg. Once gate pulses for the master leg (i.e., switches and ) are provided, the gate pulses of the other legs (slave legs) have a phase shift respect to the master leg. Using t ...
- aes journals
- aes journals

... quality have been done before and their aims frequently concentrated on the collection of raw data for a further analysis, so the impacts of various disturbances can be investigated. This thesis deals with the implementation of fact device UPQC on IEEE 14 BUS system. Different control schemes have b ...
Transformers - Sackville School
Transformers - Sackville School

... Transformers transfer power between circuits. The design of a transformer determines the characteristics of the electricity flowing in its secondary circuit. The frequency of the alternating current in the secondary circuit will always match the primary circuit, but what about current and voltage? T ...
Medium-Power-LED-Stripe MPS12-XXXX - Lumi-Con
Medium-Power-LED-Stripe MPS12-XXXX - Lumi-Con

... Before you connect to mains voltage (initially) please make sure that all necessary connections are correct. Assure that you have protection against contact for all wires including the circuit, mains voltage wires and wires to the LEDs thus no occasional contact can happen (exception: Sensor inputs ...
Introduction - The Solar Spark
Introduction - The Solar Spark

... series circuit will stop working. When circuits are wired in parallel, the voltage of each panel remains the same and the current of each panel is added. In a parallel circuit, each device has its own circuit, so if one or more device stops working or is disconnected, electricity can still flow to t ...
Solar Cells and Circuits
Solar Cells and Circuits

... series circuit will stop working. When circuits are wired in parallel, the voltage of each panel remains the same and the current of each panel is added. In a parallel circuit, each device has its own circuit, so if one or more device stops working or is disconnected, electricity can still flow to t ...
Advances in Natural and Applied Sciences
Advances in Natural and Applied Sciences

... The general MPPT circuits are unique, in the design of the power converting electronics in control strategy. The MPPT can be performed by analog control loops and fuzzy solutions, see.ref (Won, C.-Y., et al., 1994) But, traditional MPPT designs fail to cope up constraints imposed by wireless sensor ...
Monitoring System
Monitoring System

Integrated Circuit Voltage Regulators
Integrated Circuit Voltage Regulators

... 1. The amplitude of the mains supply to the PSU may change within allowed tolerances – e.g. +/- 6%. 2. The current drawn by the circuit that is receiving power may change – i.e. the effective load resistance may change. An effective voltage regulator will hold a constant supply voltage in the face o ...
ASHE
ASHE

...  Server room must have UPS  Only equipment and systems serving telecommunications space are allowed in the space  Direct corridor access is required ...
Final Presentation
Final Presentation

... Two additional cards were made for this test. This cards contained: – Voltage switching capabilities for the power up/down sequence – DIP Switch controlled address and EN signals – Analog signal, connected to a signal generator. ...
CL24579584
CL24579584

... In this paper will first discuss the why and where inverters used in wind turbine. Variable-speed wind turbines have progressed dramatically in recent years. Variable-speed operation can only be achieved by decoupling the electrical grid frequency and mechanical rotor frequency. To this end, power-e ...
1. Publications in Peer-Reviewed Journals (with impact factor)
1. Publications in Peer-Reviewed Journals (with impact factor)

... 1.10. Halevidis C.D., Koufakis E.I., Power Flow in PME Distribution Systems during an Open Neutral Condition, Power Systems, IEEE Transactions on, 28 (2013) 1083-1092. Abstract: The open neutral condition, in distribution networks, can cause significant damage to customer installations. Due to this, ...
Comparison of SVPWM and SPWM Techniques for Back to Back
Comparison of SVPWM and SPWM Techniques for Back to Back

Model Z250C4-SL Competition Four Channel Amplifier
Model Z250C4-SL Competition Four Channel Amplifier

Team 955 Electrical Certification
Team 955 Electrical Certification

... Multiple CIM DC motors are used to power the robot drive system ...
AcuRev 2000 Multi-Circuits Networked Multifunction Power and Energy Meter ISO9001  Certified
AcuRev 2000 Multi-Circuits Networked Multifunction Power and Energy Meter ISO9001 Certified

...  AcuRev 2000 provides a built-in CT option where all CTs are built inside the meter, no external CT will be needed which is ideal for new projects  High accuracy, low cost split core 333mV CTs are supplied for simple clamp-on installation- no shoring block and power shutdown is needed   during ins ...
Security1-PPT
Security1-PPT

... substations, and the main EHV/HV lines. ...
Digital Timers and Dimmer Switches
Digital Timers and Dimmer Switches

... Digital Timers may cause problems when used with a low energy lamp. This depends on how the timer switches its load on and off. If it uses a relay (electromagnetic switch) it should be fine. Problems may arise, however, if it uses a triode alternating current switch (triac) or a power transistor (A ...
12v battery charger
12v battery charger

P-6900 AR E True RMS Voltage Regulator
P-6900 AR E True RMS Voltage Regulator

... The traditional linear (transformer based) power supplies were far more robust, and as they were pushed to voltage input levels excessively high or low, they would still function (albeit with noticeably increased distortion, but this at least gave the operator valuable minutes to effect a change). W ...
A Frequency Controlled LCL - T Resonant Converter for H
A Frequency Controlled LCL - T Resonant Converter for H

... for full bridge semiconductor switches in full load range. The converter energizes the symmetrical CockcroftWalton (CW) based HV generator to achieve required high voltage. The CW circuit is an attractive solution for HV generation since it has features like low stored energy and low output ripple. ...
Power Distribution - Technion
Power Distribution - Technion

... determine the voltage and current distributions in the power/ground rails through simulation and then apply design corrections, as necessary, at various stages of the product design. The voltage distribution helps to identify parts of the power grid experiencing unacceptable voltage drop. Likewise, ...
MODIFIED MPPT SCHEME FOR IMPROVING SOLAR CELL
MODIFIED MPPT SCHEME FOR IMPROVING SOLAR CELL

VNI4140K
VNI4140K

< 1 ... 963 964 965 966 967 968 969 970 971 ... 1128 >

Power engineering



Power engineering, also called power systems engineering, is a subfield of energy engineering that deals with the generation, transmission, distribution and utilization of electric power and the electrical devices connected to such systems including generators, motors and transformers. Although much of the field is concerned with the problems of three-phase AC power – the standard for large-scale power transmission and distribution across the modern world – a significant fraction of the field is concerned with the conversion between AC and DC power and the development of specialized power systems such as those used in aircraft or for electric railway networks. It was a subfield of electrical engineering before the emergence of energy engineering.Electricity became a subject of scientific interest in the late 17th century with the work of William Gilbert. Over the next two centuries a number of important discoveries were made including the incandescent light bulb and the voltaic pile. Probably the greatest discovery with respect to power engineering came from Michael Faraday who in 1831 discovered that a change in magnetic flux induces an electromotive force in a loop of wire—a principle known as electromagnetic induction that helps explain how generators and transformers work.In 1881 two electricians built the world's first power station at Godalming in England. The station employed two waterwheels to produce an alternating current that was used to supply seven Siemens arc lamps at 250 volts and thirty-four incandescent lamps at 40 volts. However supply was intermittent and in 1882 Thomas Edison and his company, The Edison Electric Light Company, developed the first steam-powered electric power station on Pearl Street in New York City. The Pearl Street Station consisted of several generators and initially powered around 3,000 lamps for 59 customers. The power station used direct current and operated at a single voltage. Since the direct current power could not be easily transformed to the higher voltages necessary to minimise power loss during transmission, the possible distance between the generators and load was limited to around half-a-mile (800 m).That same year in London Lucien Gaulard and John Dixon Gibbs demonstrated the first transformer suitable for use in a real power system. The practical value of Gaulard and Gibbs' transformer was demonstrated in 1884 at Turin where the transformer was used to light up forty kilometres (25 miles) of railway from a single alternating current generator. Despite the success of the system, the pair made some fundamental mistakes. Perhaps the most serious was connecting the primaries of the transformers in series so that switching one lamp on or off would affect other lamps further down the line. Following the demonstration George Westinghouse, an American entrepreneur, imported a number of the transformers along with a Siemens generator and set his engineers to experimenting with them in the hopes of improving them for use in a commercial power system.One of Westinghouse's engineers, William Stanley, recognised the problem with connecting transformers in series as opposed to parallel and also realised that making the iron core of a transformer a fully enclosed loop would improve the voltage regulation of the secondary winding. Using this knowledge he built a much improved alternating current power system at Great Barrington, Massachusetts in 1886. In 1885 the Italian physicist and electrical engineer Galileo Ferraris demonstrated an induction motor and in 1887 and 1888 the Serbian-American engineer Nikola Tesla filed a range of patents related to power systems including one for a practical two-phase induction motor which Westinghouse licensed for his AC system.By 1890 the power industry had flourished and power companies had built thousands of power systems (both direct and alternating current) in the United States and Europe – these networks were effectively dedicated to providing electric lighting. During this time a fierce rivalry in the US known as the ""War of Currents"" emerged between Edison and Westinghouse over which form of transmission (direct or alternating current) was superior. In 1891, Westinghouse installed the first major power system that was designed to drive an electric motor and not just provide electric lighting. The installation powered a 100 horsepower (75 kW) synchronous motor at Telluride, Colorado with the motor being started by a Tesla induction motor. On the other side of the Atlantic, Oskar von Miller built a 20 kV 176 km three-phase transmission line from Lauffen am Neckar to Frankfurt am Main for the Electrical Engineering Exhibition in Frankfurt. In 1895, after a protracted decision-making process, the Adams No. 1 generating station at Niagara Falls began transmitting three-phase alternating current power to Buffalo at 11 kV. Following completion of the Niagara Falls project, new power systems increasingly chose alternating current as opposed to direct current for electrical transmission.Although the 1880s and 1890s were seminal decades in the field, developments in power engineering continued throughout the 20th and 21st century. In 1936 the first commercial high-voltage direct current (HVDC) line using mercury-arc valves was built between Schenectady and Mechanicville, New York. HVDC had previously been achieved by installing direct current generators in series (a system known as the Thury system) although this suffered from serious reliability issues. In 1957 Siemens demonstrated the first solid-state rectifier (solid-state rectifiers are now the standard for HVDC systems) however it was not until the early 1970s that this technology was used in commercial power systems. In 1959 Westinghouse demonstrated the first circuit breaker that used SF6 as the interrupting medium. SF6 is a far superior dielectric to air and, in recent times, its use has been extended to produce far more compact switching equipment (known as switchgear) and transformers. Many important developments also came from extending innovations in the ICT field to the power engineering field. For example, the development of computers meant load flow studies could be run more efficiently allowing for much better planning of power systems. Advances in information technology and telecommunication also allowed for much better remote control of the power system's switchgear and generators.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report