• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Chapter 1. Introduction to Electrical Power Systems (Giới Thiệu
Chapter 1. Introduction to Electrical Power Systems (Giới Thiệu

... plant is quite low, somewhere in the range of 40%. The environmental effects of electricity generation from fossil fuels are also a concern. Fly-ash is the physical matter left after coal is burned. Since fly-ash is harmful to humans, it must be disposed in an environmentally safe matter. Combustion ...
EMS+Lecture+27
EMS+Lecture+27

... Distinction between active and reactive power  Active and reactive power, are separate quantities and one cannot be converted into the other.  Both place a burden on the transmission line.  Active power eventually produces a tangible result (heat, mechanical power, light, etc.)  Reactive power ...
Power Supplies for Tetrode High Power Amplifiers at FREIA ESS TDR Contribution
Power Supplies for Tetrode High Power Amplifiers at FREIA ESS TDR Contribution

... Crowbar versus series switch. If we use crowbars the anode power supply will be out of service for many pulses after the crowbar has been triggered. The spoke cavity part of the ESS Linac is sensitive for missing RF-pulses and to improve reliability and we prefer to use a series switch instead of a ...
Power Factor improved by Variable Speed AC Drives
Power Factor improved by Variable Speed AC Drives

... The Power Factor topic is of interest to a large number of people. An Internet search with one of the search engines gave more than three million hits. There sometimes seems to be confusion between the terms Power Factor and cosϕ (phi). Just remember that the cosϕ is equal to Power Factor only in ca ...
Circuit Tester - Morris Products
Circuit Tester - Morris Products

... This tester will check for any AC or DC voltage from 80 to 500 volts - thus adequately covering the voltages found in most homes.To determine the hot side of any AC receptacle,ground one tester probe and insert the other in either side of the receptacle.The tester will glow when the hot side is touc ...
BC33315326
BC33315326

... Electronic Load Controller (ELC) based on Statcom principle is connected in shunt with the system. Vector control scheme for reference current generation technique of Statcom is developed. The major objectives in a standalone system are regulation of frequency and voltage. A battery bank is used on ...
AD4103173176
AD4103173176

... Multiplication is an essential arithmetic operation for common DSP applications, such as filtering and fast Fourier transform (FFT). To achieve high execution speed, parallel array multipliers are widely used. These multipliers tend to consume most of the power in DSP computations, and thus power-ef ...
Questions - Science @ St John`s
Questions - Science @ St John`s

... A homeowner fits a solar panel to her roof. The cost of the solar panel is £4800. The solar panel supplies an average of 800 kW h of electrical energy to the National Grid each year. The homeowner is paid 40p for each kW h of energy supplied to the National Grid. Calculate the payback time for the s ...
Power Flow Control and Voltage Profile Improvement Using Unified
Power Flow Control and Voltage Profile Improvement Using Unified

... the loop equations and methods using Gauss-type solutions. This method was laborious because the network loops has to be specified by hand by the systems engineer. The drawback of these algorithms is that they exhibit poor convergence characteristics when applied to the solution of the networks. To ...
Synchronous Generator Line Synchronization
Synchronous Generator Line Synchronization

... computer and switch on the Sorenson power supply. Increase the commanded field current to 2.5-A using the software interface. Make sure that the field supply is working by noting the current on the computer screen. Next, switch on the source panel and increase the variac to 15%. At this point, the D ...
DMS-20PC-0/1/2/8-DCM - Murata Power Solutions
DMS-20PC-0/1/2/8-DCM - Murata Power Solutions

... ➀ Operation and accuracy at inputs above or below these ranges are not specified. ...
STRMH International Future Energy Challenge ‘07
STRMH International Future Energy Challenge ‘07

... Increases overall efficiency of vehicle Decreases overall cost Take up less space ...
4N1.1 Four Analog Input to Average, Highest, Lowest, or Difference
4N1.1 Four Analog Input to Average, Highest, Lowest, or Difference

Signaling with conserved quantities: two realizations in CMOS and
Signaling with conserved quantities: two realizations in CMOS and

Kit 47. 6-10 Watt Monophonic Power Amplifier
Kit 47. 6-10 Watt Monophonic Power Amplifier

Investigating the Effects of Grid Equivalent Circuit at a Point of
Investigating the Effects of Grid Equivalent Circuit at a Point of

IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE) ISSN: 2278-1676
IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE) ISSN: 2278-1676

... The sun is a clean and renewable energy source, which produces neither waste nor any pollution through its utilization [1]. This energy is typically converted into useful energy form through natural and man made processes. Photovoltaic (PV) is a technology in which radiant energy from the sun is con ...
IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE)
IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE)

... Most of the world's electric power supply systems are widely interconnected. This is done for economic reasons, to reduce the cost of electricity and to improve reliability of power supply. Transmission interconnections enable taking advantage of diversity of loads, availability of sources, and fuel ...
Anant Kumar Tiwari, Miss. Durga Sharma, Mr.Vijay Kumar Sharma
Anant Kumar Tiwari, Miss. Durga Sharma, Mr.Vijay Kumar Sharma

... Abstract— Today everybody is fighting for power efficiency. In a industries which can be managed by power factor correction of electrical loads. Earlier the power factor correction was done by adjusting the capacitive bank manually [1]. The automated power factor corrector (APFC) using capacitive lo ...
Basic Concepts - Power and Energy
Basic Concepts - Power and Energy

Scheme and Syllabus Of Master of Technology (Power Engineering
Scheme and Syllabus Of Master of Technology (Power Engineering

... Channels for protective relaying, Selection of suitable static relaying, scheme for transmission line protection. Performance specifications of distance relays, effect of fault resistance and effects of power swings on operation of relays. Distance relay settings. Requirement of Characteristic for d ...
Electrical_Engineeri.. - Engineers Institute of India
Electrical_Engineeri.. - Engineers Institute of India

ppt
ppt

... • No warm-up time • High reliability • Low voltage (<100 V) • Air cooling • High stability • Graceful degradation ...
Unit One: AC Electronics - Helderberg Hilltowns Association
Unit One: AC Electronics - Helderberg Hilltowns Association

... – Write down the formula – Show numbers in the formula – Circle answer with the proper units ...
ISSUE OF CONCERN
ISSUE OF CONCERN

... ...
< 1 ... 938 939 940 941 942 943 944 945 946 ... 1128 >

Power engineering



Power engineering, also called power systems engineering, is a subfield of energy engineering that deals with the generation, transmission, distribution and utilization of electric power and the electrical devices connected to such systems including generators, motors and transformers. Although much of the field is concerned with the problems of three-phase AC power – the standard for large-scale power transmission and distribution across the modern world – a significant fraction of the field is concerned with the conversion between AC and DC power and the development of specialized power systems such as those used in aircraft or for electric railway networks. It was a subfield of electrical engineering before the emergence of energy engineering.Electricity became a subject of scientific interest in the late 17th century with the work of William Gilbert. Over the next two centuries a number of important discoveries were made including the incandescent light bulb and the voltaic pile. Probably the greatest discovery with respect to power engineering came from Michael Faraday who in 1831 discovered that a change in magnetic flux induces an electromotive force in a loop of wire—a principle known as electromagnetic induction that helps explain how generators and transformers work.In 1881 two electricians built the world's first power station at Godalming in England. The station employed two waterwheels to produce an alternating current that was used to supply seven Siemens arc lamps at 250 volts and thirty-four incandescent lamps at 40 volts. However supply was intermittent and in 1882 Thomas Edison and his company, The Edison Electric Light Company, developed the first steam-powered electric power station on Pearl Street in New York City. The Pearl Street Station consisted of several generators and initially powered around 3,000 lamps for 59 customers. The power station used direct current and operated at a single voltage. Since the direct current power could not be easily transformed to the higher voltages necessary to minimise power loss during transmission, the possible distance between the generators and load was limited to around half-a-mile (800 m).That same year in London Lucien Gaulard and John Dixon Gibbs demonstrated the first transformer suitable for use in a real power system. The practical value of Gaulard and Gibbs' transformer was demonstrated in 1884 at Turin where the transformer was used to light up forty kilometres (25 miles) of railway from a single alternating current generator. Despite the success of the system, the pair made some fundamental mistakes. Perhaps the most serious was connecting the primaries of the transformers in series so that switching one lamp on or off would affect other lamps further down the line. Following the demonstration George Westinghouse, an American entrepreneur, imported a number of the transformers along with a Siemens generator and set his engineers to experimenting with them in the hopes of improving them for use in a commercial power system.One of Westinghouse's engineers, William Stanley, recognised the problem with connecting transformers in series as opposed to parallel and also realised that making the iron core of a transformer a fully enclosed loop would improve the voltage regulation of the secondary winding. Using this knowledge he built a much improved alternating current power system at Great Barrington, Massachusetts in 1886. In 1885 the Italian physicist and electrical engineer Galileo Ferraris demonstrated an induction motor and in 1887 and 1888 the Serbian-American engineer Nikola Tesla filed a range of patents related to power systems including one for a practical two-phase induction motor which Westinghouse licensed for his AC system.By 1890 the power industry had flourished and power companies had built thousands of power systems (both direct and alternating current) in the United States and Europe – these networks were effectively dedicated to providing electric lighting. During this time a fierce rivalry in the US known as the ""War of Currents"" emerged between Edison and Westinghouse over which form of transmission (direct or alternating current) was superior. In 1891, Westinghouse installed the first major power system that was designed to drive an electric motor and not just provide electric lighting. The installation powered a 100 horsepower (75 kW) synchronous motor at Telluride, Colorado with the motor being started by a Tesla induction motor. On the other side of the Atlantic, Oskar von Miller built a 20 kV 176 km three-phase transmission line from Lauffen am Neckar to Frankfurt am Main for the Electrical Engineering Exhibition in Frankfurt. In 1895, after a protracted decision-making process, the Adams No. 1 generating station at Niagara Falls began transmitting three-phase alternating current power to Buffalo at 11 kV. Following completion of the Niagara Falls project, new power systems increasingly chose alternating current as opposed to direct current for electrical transmission.Although the 1880s and 1890s were seminal decades in the field, developments in power engineering continued throughout the 20th and 21st century. In 1936 the first commercial high-voltage direct current (HVDC) line using mercury-arc valves was built between Schenectady and Mechanicville, New York. HVDC had previously been achieved by installing direct current generators in series (a system known as the Thury system) although this suffered from serious reliability issues. In 1957 Siemens demonstrated the first solid-state rectifier (solid-state rectifiers are now the standard for HVDC systems) however it was not until the early 1970s that this technology was used in commercial power systems. In 1959 Westinghouse demonstrated the first circuit breaker that used SF6 as the interrupting medium. SF6 is a far superior dielectric to air and, in recent times, its use has been extended to produce far more compact switching equipment (known as switchgear) and transformers. Many important developments also came from extending innovations in the ICT field to the power engineering field. For example, the development of computers meant load flow studies could be run more efficiently allowing for much better planning of power systems. Advances in information technology and telecommunication also allowed for much better remote control of the power system's switchgear and generators.