• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Load Models, including Induction Machines
Load Models, including Induction Machines

... – A stationary stator, which is supplied with an ac voltage; windings in stator create a rotating magnetic field – A rotating rotor, in which an ac current is induced (hence the name) ...
The Grid and its Future - Companion Piece to Summer 2015
The Grid and its Future - Companion Piece to Summer 2015

... blowing) and automatically disconnect when the energy supply is not available.  As part of the “self  dispatching” capabilities of distributed generators, their control systems can also be set up to detect  small changes in frequency. If there are too many generators available, the frequency increas ...
Abstract - PG Embedded systems
Abstract - PG Embedded systems

... The converters adopting the transformer, such as flyback, forward, push–pull, half-bridge, and full-bridge types, can be used to obtain high voltage gain by adjusting the turns ratio of the transformer. Among them, the flyback converter is very widely used in low power applications due to the simple ...
A308 Integrated Amplifier - Puerto Rico Suppliers .com
A308 Integrated Amplifier - Puerto Rico Suppliers .com

... With at least 150 watts per channel, huge current reserves and extremely low distortion over a very wide bandwidth and impedance range, the A308 dual mono integrated amplifier represents an extraordinarily high standard of performance. It used Musical Fidelity's latest circuit development, which tak ...
RakLink Diagnostics and Useful Information
RakLink Diagnostics and Useful Information

d93 Electricity and Magnetism
d93 Electricity and Magnetism

... Describe how charged particles react to each other. Explain how an electric field affects charged particles around them. Identify 3 ways that objects can become electrically charged. Explain why you can get a shock from a door knob. Compare and contrast AC and DC current. Explain why materials eithe ...
SIMPLE SYSTEM PLANNING WITH REFUsol
SIMPLE SYSTEM PLANNING WITH REFUsol

RB715Z
RB715Z

... otherwise dispose of the same, no express or implied right or license to practice or commercially exploit any intellectual property rights or other proprietary rights owned or controlled by ROHM CO., LTD. is granted to any such buyer. Products listed in this document are no antiradiation design. ...
Application Note GaAs MMIC Based Control Components with Integral Drivers  Introduction
Application Note GaAs MMIC Based Control Components with Integral Drivers Introduction

... of the pulse contains many higher frequency components. The number of components and their contribution is determined by the sharpness of the pulse edges. In addition, the MESFETs are nonlinear devices that generate harmonics of the incident signals. The fundamental switching structure filters out s ...
Diris A40
Diris A40

... - 1 fixed terminal blocks 6 mm2 for current, - 1 removable terminal blocks 2,5 mm2 for voltage, - 1 removable terminal blocks 2,5 mm2 for auxiliary supply, impulse outputs , analogue outputs, inputs and outputs. - This device is installed on single, 2, 3 or 4-wire balanced or unbalanced three-phase ...
Penang Branch
Penang Branch

SSPA 0.5-2.5-50 DS_SSPA 0.5-2.5-50 DS.qxd
SSPA 0.5-2.5-50 DS_SSPA 0.5-2.5-50 DS.qxd

1 or 2Ø – High Performance AC Power Source 6,000VA 15
1 or 2Ø – High Performance AC Power Source 6,000VA 15

intelligent control scheme for mitigating voltage sag and
intelligent control scheme for mitigating voltage sag and

... Neeraj Jain*, Prof. Aziz Ahmad P.G Elect.Engg Dept., Al-Falah University, Faridabad, Haryana Professor at Department of Electrical &Electronics Engineernig, Al-Falah University, Faridabad,Haryana DOI: 10.5281/zenodo.60833 ABSTRACT The higher power demand and competitive environment of electric power ...
Transcutaneous Energy Transfer System for Powering Implantable
Transcutaneous Energy Transfer System for Powering Implantable

Today`s Objectives
Today`s Objectives

... A simple circuit… ...
PV Systems and Safety
PV Systems and Safety

... Currents above 10 mA* can paralyze or “freeze” muscles. Currents more than 75 mA can cause a rapid, ineffective heartbeat -- death will occur in a few minutes unless a defibrillator is used. 75 mA is not much current – a small power drill uses 30 times as much. ...
P09454: Flow Visualization
P09454: Flow Visualization

... JAMES BROWN ...
Variable Hysteresis Band Current Controller for Power
Variable Hysteresis Band Current Controller for Power

... In Equation (5),vα iα and vβ iβ are instantaneous real (p) and imaginary (q) powers. Since these equations are products of instantaneous currents and voltages in the same axis. In three-phase circuits, instantaneous real power is p and its unit is watt. In contrast vα iβ and vβ iα are not instantane ...
Avtron LPV700S Compact, Portable Load Bank - 500 to 700 KW
Avtron LPV700S Compact, Portable Load Bank - 500 to 700 KW

... The Avtron LPV700S Load Bank is ideal for routine load testing of standby diesel generating systems at remote sites or for factory production line testing of (UPS) Uninterruptible Power Supplies, turbines, or engine generator sets. This model provides resistive loading up to 700 KW at 240/480 Volts ...
Celiano Portero - Stevens Institute of Technology
Celiano Portero - Stevens Institute of Technology

... ϕ: rotor magnetic flux (Wb) ω: angle velocity of rotor speed (rad/sec) Because the rotating magnetic field is fixed and the rotor rotating speed varies with the load unbalance, the output voltage and frequency are variable and cannot provide a stable power supply. The produced power must be run thro ...
Loop Power Sensors Loop Power, 4
Loop Power Sensors Loop Power, 4

Stochastic Analysis of the Effect of Using Harmonic Generators in
Stochastic Analysis of the Effect of Using Harmonic Generators in

ps-24-1m operation and installation instructions
ps-24-1m operation and installation instructions

... the other hand, if batteries are used, they will switch into the short when the board shuts down and will supply a tremendous amount of current into a short which is capable of melting wire insulation. To protect against a short circuit when batteries are being employed, a 2.5 Amp DC Polyswitch brea ...
Why led driver why not just normal dc power supply
Why led driver why not just normal dc power supply

... not ok in the second circuit voltage regulation across the diode was good but current regulation was not good only in the third circuit where voltage and current across the diode were very good ..and remember that the ultimate goal of led driver board is to keep current constant in the led.. One mor ...
< 1 ... 915 916 917 918 919 920 921 922 923 ... 1128 >

Power engineering



Power engineering, also called power systems engineering, is a subfield of energy engineering that deals with the generation, transmission, distribution and utilization of electric power and the electrical devices connected to such systems including generators, motors and transformers. Although much of the field is concerned with the problems of three-phase AC power – the standard for large-scale power transmission and distribution across the modern world – a significant fraction of the field is concerned with the conversion between AC and DC power and the development of specialized power systems such as those used in aircraft or for electric railway networks. It was a subfield of electrical engineering before the emergence of energy engineering.Electricity became a subject of scientific interest in the late 17th century with the work of William Gilbert. Over the next two centuries a number of important discoveries were made including the incandescent light bulb and the voltaic pile. Probably the greatest discovery with respect to power engineering came from Michael Faraday who in 1831 discovered that a change in magnetic flux induces an electromotive force in a loop of wire—a principle known as electromagnetic induction that helps explain how generators and transformers work.In 1881 two electricians built the world's first power station at Godalming in England. The station employed two waterwheels to produce an alternating current that was used to supply seven Siemens arc lamps at 250 volts and thirty-four incandescent lamps at 40 volts. However supply was intermittent and in 1882 Thomas Edison and his company, The Edison Electric Light Company, developed the first steam-powered electric power station on Pearl Street in New York City. The Pearl Street Station consisted of several generators and initially powered around 3,000 lamps for 59 customers. The power station used direct current and operated at a single voltage. Since the direct current power could not be easily transformed to the higher voltages necessary to minimise power loss during transmission, the possible distance between the generators and load was limited to around half-a-mile (800 m).That same year in London Lucien Gaulard and John Dixon Gibbs demonstrated the first transformer suitable for use in a real power system. The practical value of Gaulard and Gibbs' transformer was demonstrated in 1884 at Turin where the transformer was used to light up forty kilometres (25 miles) of railway from a single alternating current generator. Despite the success of the system, the pair made some fundamental mistakes. Perhaps the most serious was connecting the primaries of the transformers in series so that switching one lamp on or off would affect other lamps further down the line. Following the demonstration George Westinghouse, an American entrepreneur, imported a number of the transformers along with a Siemens generator and set his engineers to experimenting with them in the hopes of improving them for use in a commercial power system.One of Westinghouse's engineers, William Stanley, recognised the problem with connecting transformers in series as opposed to parallel and also realised that making the iron core of a transformer a fully enclosed loop would improve the voltage regulation of the secondary winding. Using this knowledge he built a much improved alternating current power system at Great Barrington, Massachusetts in 1886. In 1885 the Italian physicist and electrical engineer Galileo Ferraris demonstrated an induction motor and in 1887 and 1888 the Serbian-American engineer Nikola Tesla filed a range of patents related to power systems including one for a practical two-phase induction motor which Westinghouse licensed for his AC system.By 1890 the power industry had flourished and power companies had built thousands of power systems (both direct and alternating current) in the United States and Europe – these networks were effectively dedicated to providing electric lighting. During this time a fierce rivalry in the US known as the ""War of Currents"" emerged between Edison and Westinghouse over which form of transmission (direct or alternating current) was superior. In 1891, Westinghouse installed the first major power system that was designed to drive an electric motor and not just provide electric lighting. The installation powered a 100 horsepower (75 kW) synchronous motor at Telluride, Colorado with the motor being started by a Tesla induction motor. On the other side of the Atlantic, Oskar von Miller built a 20 kV 176 km three-phase transmission line from Lauffen am Neckar to Frankfurt am Main for the Electrical Engineering Exhibition in Frankfurt. In 1895, after a protracted decision-making process, the Adams No. 1 generating station at Niagara Falls began transmitting three-phase alternating current power to Buffalo at 11 kV. Following completion of the Niagara Falls project, new power systems increasingly chose alternating current as opposed to direct current for electrical transmission.Although the 1880s and 1890s were seminal decades in the field, developments in power engineering continued throughout the 20th and 21st century. In 1936 the first commercial high-voltage direct current (HVDC) line using mercury-arc valves was built between Schenectady and Mechanicville, New York. HVDC had previously been achieved by installing direct current generators in series (a system known as the Thury system) although this suffered from serious reliability issues. In 1957 Siemens demonstrated the first solid-state rectifier (solid-state rectifiers are now the standard for HVDC systems) however it was not until the early 1970s that this technology was used in commercial power systems. In 1959 Westinghouse demonstrated the first circuit breaker that used SF6 as the interrupting medium. SF6 is a far superior dielectric to air and, in recent times, its use has been extended to produce far more compact switching equipment (known as switchgear) and transformers. Many important developments also came from extending innovations in the ICT field to the power engineering field. For example, the development of computers meant load flow studies could be run more efficiently allowing for much better planning of power systems. Advances in information technology and telecommunication also allowed for much better remote control of the power system's switchgear and generators.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report