• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
VSWR and Antenna Tuners
VSWR and Antenna Tuners

... A transmission line can be thought of as an infinite number of small series inductors on each leg of the transmission line with small capacitors coupling between the them. This model applies to all transmission lines whether open wire, ladder line, twin lead or coax. The characteristic impedance of ...
SP3223EB 数据资料DataSheet下载
SP3223EB 数据资料DataSheet下载

balun basics primer
balun basics primer

Technical Article - Polymeric Insulators
Technical Article - Polymeric Insulators

... In the early 1960s, distribution class (CE) insulators were first sold commercially in the U.S. under the name GEPOL. These units failed due to surface damage and puncture. CE was used later in experimental 500 kV station breaker bushings, and in 115 kV bushings in the 1970s, and for suspension insu ...
Full-text PDF (accepted author manuscript)
Full-text PDF (accepted author manuscript)

... Multilevel converters have superior characteristics over the standard two-level converter such as reduced output harmonics, lower dv/dt and switching loss. They are widely used in high or medium voltage (>3kV) power conversion systems thanks to their capability to handle higher voltage and higher po ...
PAM2305 Description Pin Assignments
PAM2305 Description Pin Assignments

... In continuous mode, the source current of the top MOSFET is a square wave of duty cycle VOUT/VIN. To prevent large voltage transients, a low ESR input capacitor sized for the maximum RMS current must be used. The maximum RMS capacitor current is given by: ...
CSI 16260_MCP-E2
CSI 16260_MCP-E2

This is a shot of 48 circuit boards available in the classroom for
This is a shot of 48 circuit boards available in the classroom for

... Every auto – truck – heavy duty technician needs more electrical training. There are many options open to technicians to acquire electrical training, such as, attending a tech school but that isn’t always the best option. Some companies provide electrical training that is mostly covering basic elect ...
Telit_UE866_Hardware_User_Guide_r11
Telit_UE866_Hardware_User_Guide_r11

Planning Guidelines - SUNNY TRIPOWER 60
Planning Guidelines - SUNNY TRIPOWER 60

... The functional safety circuit has a fully redundant integrated single-fault detection. If a fault occurs, the inverter disconnects from the grid immediately. The method is active and covers all circuitry within the residual current monitoring, both for continuous levels and sudden changes. In order ...
LTM4628 - Dual 8A or Single 16A DC/DC uModule Regulator
LTM4628 - Dual 8A or Single 16A DC/DC uModule Regulator

... TRACK1, TRACK2 (E5, D8): Output Voltage Tracking Pin and Soft-Start Inputs. Each channel has a 1.3µA pull-up current source. When one channel is configured to be master of the two channels, then a capacitor from this pin to ground will set a soft-start ramp rate. The remaining channel can be set up ...
Application Note Evaluation Board 3kW dual phase LLC
Application Note Evaluation Board 3kW dual phase LLC

... In order words, this requirement involves the need for a very flat efficiency plot, at least from 40-50% up to 100% load. On the other hand, in N+1 redundant application, the percentage of SMPS operation near full load is relatively lower compared to the one below half load, making this reason also ...
AN 224: High-Speed Board Layout Guidelines
AN 224: High-Speed Board Layout Guidelines

... line tightly to the ground plane and help decouple it from adjacent signals. Use differential routing techniques where possible, especially for critical nets (i.e., match the lengths as well as the gyrations that each trace goes through). If there is significant coupling, route single-ended signals ...
ISA_ISABELLA LX_428000085237_EN.indd
ISA_ISABELLA LX_428000085237_EN.indd

... caused by the displaying of products other than those described above. Never use electric devices inside this appliance. Do not use mechanical or other means to accelerate the defrosting process, other than recommended by the manufacturer. Keep the air vents in the casing of the appliance or in the ...
Equipment Life Extension and Modernization of Generator
Equipment Life Extension and Modernization of Generator

... Eaton, USA ...
iQ Series Ultrasonic Generator/Power Supply Auto-Plus
iQ Series Ultrasonic Generator/Power Supply Auto-Plus

... output amplitude level is held to within ±1% to provide weld process consistency and reduced weld cycle times. ...
REVIEW ARTICLE Josephson voltage standards
REVIEW ARTICLE Josephson voltage standards

... obtain the largest voltage from the smallest number of junctions, an array standard requires a circuit design that can deliver nearly uniform microwave power to many thousands of junctions, all of which are connected in series. The solution to this problem is a simple extension of Fig. 3 to a series ...
Towards Securing Low-Power Digital Circuits with Ultra
Towards Securing Low-Power Digital Circuits with Ultra

... strictly necessary that the original signal is hidden by a sufficient physical noise, i.e. that the original SNR is sufficiently small. Intuitively, this is because mathematical countermeasures can only amplify the impact of the physical noise (and therefore fall short if there is nothing to amplify ...
DIPLOMAT LOGIC Manual
DIPLOMAT LOGIC Manual

... The symbol shown below is used to call your attention to instructions concerning your personal safety and the safety of others. Watch for this symbol. It points out important safety precautions. It means ATTENTION! Become Alert! Your personal safety is at risk! Read the message that follows and be a ...
3. Sizing and general characteristics
3. Sizing and general characteristics

PAM2803 Description Pin Assignments
PAM2803 Description Pin Assignments

... Diodes Incorporated products are specifically not authorized for use as critical components in life support devices or systems without the express written approval of the Chief Executive Officer of Diodes Incorporated. As used herein: A. Life support devices or systems are devices or systems which: ...
Laser PCB Milling Machine - Department of Electrical Engineering
Laser PCB Milling Machine - Department of Electrical Engineering

... Quick Circuit 5000 PCB milling machine in the senior design lab. As two of our group are ARC members, and are tasked with keeping the machine repaired and running, we have found this to be an increasingly difficult task. In just the last year we have had to replace the lead screw, and are currently ...
Cap-Free NMOS 250mA Lower Dropout
Cap-Free NMOS 250mA Lower Dropout

... stability, it is good analog design practice to connect a 0.1 µF to 1 µF low ESR capacitor across the input supply near the regulator. This counteracts reactive input sources and improves transient response, noise rejection, and ripple rejection. A higher-value capacitor may be necessary if large, f ...
Power Supply Module 230 V MDP 102-1 1 Overview
Power Supply Module 230 V MDP 102-1 1 Overview

... Protected extra low voltage Resolver AC voltage DC voltage ...
BD88200GUL
BD88200GUL

... BD88xxxGUL is output coupling capacitorless headphone amplifier. This IC has a negative voltage generator of regulated type built-in and generates the direct regulated negative voltage from the supply voltage. It is possible to drive headphones in a ground standard with both voltage of the positive ...
< 1 ... 82 83 84 85 86 87 88 89 90 ... 1128 >

Power engineering



Power engineering, also called power systems engineering, is a subfield of energy engineering that deals with the generation, transmission, distribution and utilization of electric power and the electrical devices connected to such systems including generators, motors and transformers. Although much of the field is concerned with the problems of three-phase AC power – the standard for large-scale power transmission and distribution across the modern world – a significant fraction of the field is concerned with the conversion between AC and DC power and the development of specialized power systems such as those used in aircraft or for electric railway networks. It was a subfield of electrical engineering before the emergence of energy engineering.Electricity became a subject of scientific interest in the late 17th century with the work of William Gilbert. Over the next two centuries a number of important discoveries were made including the incandescent light bulb and the voltaic pile. Probably the greatest discovery with respect to power engineering came from Michael Faraday who in 1831 discovered that a change in magnetic flux induces an electromotive force in a loop of wire—a principle known as electromagnetic induction that helps explain how generators and transformers work.In 1881 two electricians built the world's first power station at Godalming in England. The station employed two waterwheels to produce an alternating current that was used to supply seven Siemens arc lamps at 250 volts and thirty-four incandescent lamps at 40 volts. However supply was intermittent and in 1882 Thomas Edison and his company, The Edison Electric Light Company, developed the first steam-powered electric power station on Pearl Street in New York City. The Pearl Street Station consisted of several generators and initially powered around 3,000 lamps for 59 customers. The power station used direct current and operated at a single voltage. Since the direct current power could not be easily transformed to the higher voltages necessary to minimise power loss during transmission, the possible distance between the generators and load was limited to around half-a-mile (800 m).That same year in London Lucien Gaulard and John Dixon Gibbs demonstrated the first transformer suitable for use in a real power system. The practical value of Gaulard and Gibbs' transformer was demonstrated in 1884 at Turin where the transformer was used to light up forty kilometres (25 miles) of railway from a single alternating current generator. Despite the success of the system, the pair made some fundamental mistakes. Perhaps the most serious was connecting the primaries of the transformers in series so that switching one lamp on or off would affect other lamps further down the line. Following the demonstration George Westinghouse, an American entrepreneur, imported a number of the transformers along with a Siemens generator and set his engineers to experimenting with them in the hopes of improving them for use in a commercial power system.One of Westinghouse's engineers, William Stanley, recognised the problem with connecting transformers in series as opposed to parallel and also realised that making the iron core of a transformer a fully enclosed loop would improve the voltage regulation of the secondary winding. Using this knowledge he built a much improved alternating current power system at Great Barrington, Massachusetts in 1886. In 1885 the Italian physicist and electrical engineer Galileo Ferraris demonstrated an induction motor and in 1887 and 1888 the Serbian-American engineer Nikola Tesla filed a range of patents related to power systems including one for a practical two-phase induction motor which Westinghouse licensed for his AC system.By 1890 the power industry had flourished and power companies had built thousands of power systems (both direct and alternating current) in the United States and Europe – these networks were effectively dedicated to providing electric lighting. During this time a fierce rivalry in the US known as the ""War of Currents"" emerged between Edison and Westinghouse over which form of transmission (direct or alternating current) was superior. In 1891, Westinghouse installed the first major power system that was designed to drive an electric motor and not just provide electric lighting. The installation powered a 100 horsepower (75 kW) synchronous motor at Telluride, Colorado with the motor being started by a Tesla induction motor. On the other side of the Atlantic, Oskar von Miller built a 20 kV 176 km three-phase transmission line from Lauffen am Neckar to Frankfurt am Main for the Electrical Engineering Exhibition in Frankfurt. In 1895, after a protracted decision-making process, the Adams No. 1 generating station at Niagara Falls began transmitting three-phase alternating current power to Buffalo at 11 kV. Following completion of the Niagara Falls project, new power systems increasingly chose alternating current as opposed to direct current for electrical transmission.Although the 1880s and 1890s were seminal decades in the field, developments in power engineering continued throughout the 20th and 21st century. In 1936 the first commercial high-voltage direct current (HVDC) line using mercury-arc valves was built between Schenectady and Mechanicville, New York. HVDC had previously been achieved by installing direct current generators in series (a system known as the Thury system) although this suffered from serious reliability issues. In 1957 Siemens demonstrated the first solid-state rectifier (solid-state rectifiers are now the standard for HVDC systems) however it was not until the early 1970s that this technology was used in commercial power systems. In 1959 Westinghouse demonstrated the first circuit breaker that used SF6 as the interrupting medium. SF6 is a far superior dielectric to air and, in recent times, its use has been extended to produce far more compact switching equipment (known as switchgear) and transformers. Many important developments also came from extending innovations in the ICT field to the power engineering field. For example, the development of computers meant load flow studies could be run more efficiently allowing for much better planning of power systems. Advances in information technology and telecommunication also allowed for much better remote control of the power system's switchgear and generators.