• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE) e-ISSN: 2278-1676,p-ISSN: 2320-3331
IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE) e-ISSN: 2278-1676,p-ISSN: 2320-3331

... nowadays. It is now essential for an electrical engineer to understand the concept of simulation to study the system or circuit behaviour without damaging it .The tools for doing the simulation in various fields are available in the market for engineering professionals. Many industries are spending ...
Aalborg Universitet Wind Power Plant
Aalborg Universitet Wind Power Plant

... attain the required dc operating voltage. Unlike other high­ voltage VSC topologies, the MMC avoids the difficulty of connecting semiconductor switches in series. The voltage rating can be scaled by simply adding additional sub-modules to the stack. Thus, it becomes easier to construct VSCs with ver ...
Electical Circuits - World of Teaching
Electical Circuits - World of Teaching

... The components are connected end-to-end, one after the other. They make a simple loop for the current to flow round. If one bulb ‘blows’ it breaks the whole circuit and all the bulbs go out. ...
Slides
Slides

... • Where z = y – x ...
IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE) e-ISSN: 2278-1676,p-ISSN: 2320-3331,
IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE) e-ISSN: 2278-1676,p-ISSN: 2320-3331,

... Abstract: The control of a grid interfacing inverter with integrated voltage unbalance correction. It is proposed to add an additional function to the inverter to decrease the negative-sequence voltage at the point of connection with the utility grid. Based on symmetric sequence voltage decompositio ...
8.3 Electrical Current 2
8.3 Electrical Current 2

... to move through, a device (load) that runs off the energy that the current gives it and a switch to start and stop current flow. ...
CR26645650
CR26645650

... prototype was tested with the simulation program. Then, the prototype for experiment has been setup for verifying the performance of system. It was found that reactive power could be compensated and harmonic current could be reduce compared to the results of an active power filter with the load curr ...
ComboLight New Construction Recessed w/Trim - 12V AR111 - 3 Light
ComboLight New Construction Recessed w/Trim - 12V AR111 - 3 Light

... conductors or 60º C for end of run. The fixture is also UL listed as ‘access above ceiling not required’. D.... Electrical Electrical accessible through ceiling opening. J-Box located on the side wall of the housing behind removable access doors. Integral electronic or magnetic low voltage transform ...
ComboLight New Construction Recessed w/Trim - 12V AR111 - 5 Light
ComboLight New Construction Recessed w/Trim - 12V AR111 - 5 Light

... conductors or 60º C for end of run. The fixture is also UL listed as ‘access above ceiling not required’. ...
ComboLight New Construction Recessed w/Trim - 12V AR111 - 2 Light
ComboLight New Construction Recessed w/Trim - 12V AR111 - 2 Light

... conductors or 60º C for end of run. The fixture is also UL listed as ‘access above ceiling not required’. ...
High Efficiency, Inductorless Step-Down DC/DC Converter
High Efficiency, Inductorless Step-Down DC/DC Converter

... load current. f is divided from the base clock, half for G=1/2; one-third for G=2/3; and LDO control for G=1. In other control methodology, such as PFM and PWM, d or f varies with both input voltage and load current, it can not achieve small ripple under all conditions. But when the load resistor be ...
the electric circuits and electronics laboratory
the electric circuits and electronics laboratory

... Realization of a conceptual design is probably one of the most fulfilling experience of every engineering student. In the advent of computer technology, the implementation of an electrical or electronic systems design has been revolutionized through the use of various computer simulation and hardwar ...
SEPIC Converter Based Dynamic Power Tracking From Wind
SEPIC Converter Based Dynamic Power Tracking From Wind

... energy is obtained from fossil fuels like coal, crude oil, natural gas etc., once used they cannot be restored or replenished. Burning of fossil fuel pollutes our surroundings by producing by-products like nitrous oxide, sulphur dioxide and it leads to global warming. To overcome the above problems, ...
Users` Manual - Mapletree Audio Design
Users` Manual - Mapletree Audio Design

... input source or matching different sources to the optimum circuit topology. The two active topologies and the passive path have different voltage gains so that switching between topologies can cause a sudden increase in loudness. This can be avoided by reducing the volume before switching and then r ...
Pax Presentation
Pax Presentation

... • 2 kV output (peak) • DC – 1 kHz @ 50 mA max current • Capacitance range o 4 µF @ 1 Hz o 80 nF @ 50 Hz (67 nF @ 60 Hz) o 4 nF @ 1 kHz ...
DND5057 - pes-psrc
DND5057 - pes-psrc

... (blocking) frequency. External faults do not produce loss of channel. See: directional comparison protection. Disc-type reactor. A high-voltage shunt reactor that is constructed of disk-type coils. These coils are wound with one or more copper straps in parallel. The first turn is wrapped around an ...
bachelor`s degree in electrical engineering technology
bachelor`s degree in electrical engineering technology

... Transfer Theorems. 4. simulate the operation of electric circuit using computer simulation software. 5. assemble electrical components correctly and measure electrical quantities for DC circuits. SYNOPSIS This subject introduces the students to Ohm’s Law, Kircchoff’s Laws and use them to calculate c ...
how to do the power supply paper clip test?
how to do the power supply paper clip test?

... Once this is done, make sure that the power cord is NOT connected to the power supply then connect one end of the paper clip to the green wire and the other end to one of the black wires present on the connector as shown below: ...
RID1801  Cordless Impact Driver ORIGINAL
RID1801 Cordless Impact Driver ORIGINAL



ComboLight New Construction Recessed w/Trim - 12V AR111 - 6 Light
ComboLight New Construction Recessed w/Trim - 12V AR111 - 6 Light

... conductors or 60º C for end of run. The fixture is also UL listed as ‘access above ceiling not required’. ...
2.1 Fundamental DC-DC Converter Topologies These graphics
2.1 Fundamental DC-DC Converter Topologies These graphics

... cycle and switching frequency are normally predetermined. Generally a switching frequency between 200 kHz and 300 kHz is a good compromise between the switching losses and filter requirements. The usable maximum duty cycle is normally limited by the PWM controller. In an LM5020, there are two versio ...
TEACHING AND DEMONSTRATION OF OPTIMIZED DESIGN
TEACHING AND DEMONSTRATION OF OPTIMIZED DESIGN

Power Consumption
Power Consumption

... (square root of the phase) = (242 volts) * (5.2 amps) * (0.8) * (1) = 1007 watts = 1.0 kilowatts Second, determine how many hours per day the pump will run: hours run per day = (times run per day) * (length of each time in minutes) / (60 minutes per hour) = (8 times per day) * (10 minutes each) / (6 ...
Building a CTI Power Supply
Building a CTI Power Supply

< 1 ... 835 836 837 838 839 840 841 842 843 ... 1128 >

Power engineering



Power engineering, also called power systems engineering, is a subfield of energy engineering that deals with the generation, transmission, distribution and utilization of electric power and the electrical devices connected to such systems including generators, motors and transformers. Although much of the field is concerned with the problems of three-phase AC power – the standard for large-scale power transmission and distribution across the modern world – a significant fraction of the field is concerned with the conversion between AC and DC power and the development of specialized power systems such as those used in aircraft or for electric railway networks. It was a subfield of electrical engineering before the emergence of energy engineering.Electricity became a subject of scientific interest in the late 17th century with the work of William Gilbert. Over the next two centuries a number of important discoveries were made including the incandescent light bulb and the voltaic pile. Probably the greatest discovery with respect to power engineering came from Michael Faraday who in 1831 discovered that a change in magnetic flux induces an electromotive force in a loop of wire—a principle known as electromagnetic induction that helps explain how generators and transformers work.In 1881 two electricians built the world's first power station at Godalming in England. The station employed two waterwheels to produce an alternating current that was used to supply seven Siemens arc lamps at 250 volts and thirty-four incandescent lamps at 40 volts. However supply was intermittent and in 1882 Thomas Edison and his company, The Edison Electric Light Company, developed the first steam-powered electric power station on Pearl Street in New York City. The Pearl Street Station consisted of several generators and initially powered around 3,000 lamps for 59 customers. The power station used direct current and operated at a single voltage. Since the direct current power could not be easily transformed to the higher voltages necessary to minimise power loss during transmission, the possible distance between the generators and load was limited to around half-a-mile (800 m).That same year in London Lucien Gaulard and John Dixon Gibbs demonstrated the first transformer suitable for use in a real power system. The practical value of Gaulard and Gibbs' transformer was demonstrated in 1884 at Turin where the transformer was used to light up forty kilometres (25 miles) of railway from a single alternating current generator. Despite the success of the system, the pair made some fundamental mistakes. Perhaps the most serious was connecting the primaries of the transformers in series so that switching one lamp on or off would affect other lamps further down the line. Following the demonstration George Westinghouse, an American entrepreneur, imported a number of the transformers along with a Siemens generator and set his engineers to experimenting with them in the hopes of improving them for use in a commercial power system.One of Westinghouse's engineers, William Stanley, recognised the problem with connecting transformers in series as opposed to parallel and also realised that making the iron core of a transformer a fully enclosed loop would improve the voltage regulation of the secondary winding. Using this knowledge he built a much improved alternating current power system at Great Barrington, Massachusetts in 1886. In 1885 the Italian physicist and electrical engineer Galileo Ferraris demonstrated an induction motor and in 1887 and 1888 the Serbian-American engineer Nikola Tesla filed a range of patents related to power systems including one for a practical two-phase induction motor which Westinghouse licensed for his AC system.By 1890 the power industry had flourished and power companies had built thousands of power systems (both direct and alternating current) in the United States and Europe – these networks were effectively dedicated to providing electric lighting. During this time a fierce rivalry in the US known as the ""War of Currents"" emerged between Edison and Westinghouse over which form of transmission (direct or alternating current) was superior. In 1891, Westinghouse installed the first major power system that was designed to drive an electric motor and not just provide electric lighting. The installation powered a 100 horsepower (75 kW) synchronous motor at Telluride, Colorado with the motor being started by a Tesla induction motor. On the other side of the Atlantic, Oskar von Miller built a 20 kV 176 km three-phase transmission line from Lauffen am Neckar to Frankfurt am Main for the Electrical Engineering Exhibition in Frankfurt. In 1895, after a protracted decision-making process, the Adams No. 1 generating station at Niagara Falls began transmitting three-phase alternating current power to Buffalo at 11 kV. Following completion of the Niagara Falls project, new power systems increasingly chose alternating current as opposed to direct current for electrical transmission.Although the 1880s and 1890s were seminal decades in the field, developments in power engineering continued throughout the 20th and 21st century. In 1936 the first commercial high-voltage direct current (HVDC) line using mercury-arc valves was built between Schenectady and Mechanicville, New York. HVDC had previously been achieved by installing direct current generators in series (a system known as the Thury system) although this suffered from serious reliability issues. In 1957 Siemens demonstrated the first solid-state rectifier (solid-state rectifiers are now the standard for HVDC systems) however it was not until the early 1970s that this technology was used in commercial power systems. In 1959 Westinghouse demonstrated the first circuit breaker that used SF6 as the interrupting medium. SF6 is a far superior dielectric to air and, in recent times, its use has been extended to produce far more compact switching equipment (known as switchgear) and transformers. Many important developments also came from extending innovations in the ICT field to the power engineering field. For example, the development of computers meant load flow studies could be run more efficiently allowing for much better planning of power systems. Advances in information technology and telecommunication also allowed for much better remote control of the power system's switchgear and generators.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report