• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Active Power Factor Correction Project - Mustafa`s E
Active Power Factor Correction Project - Mustafa`s E

... Figure 3 full wave bridge rectifier with smoothing capacitor ....................................................................... 9 Figure 4the capacitor is only charge in short period of time ...................................................................... 10 Figure 5 output of the smoothi ...
ultra high voltage operational amplifier
ultra high voltage operational amplifier

... For larger values of load capacitance, the output snubber network may be omitted. If loop stability becomes a problem due to excessively high load capacitance, a 100 ohm resistor may be added between the output of the amplifier and the load. A small tradeoff with bandwidth must be made in this confi ...
IEEE Paper Template in A4 (V1)
IEEE Paper Template in A4 (V1)

... from the direct stroke by the overhead wires, the lightning current level stroking the lines directly is usually lower than that of tower top. The magnitude and the waveform of the surge transferred to the electric equipment at the power plant depend on the magnitude and on the location of the strok ...
multimess D9-PQ - KBR Kompensationsanlagenbau
multimess D9-PQ - KBR Kompensationsanlagenbau

... Active power, total Active power, extremes Reactive power, phase Reactive power, total Reactive power, extremes Apparent power, phase Apparent power, total Fundamental active power, phase Fundamental active power, total Fundamental active power, phase Fundamental reactive power (shift), total Fundam ...
EN14 107 Basics of Electrical and Electronics & Communication Engg.
EN14 107 Basics of Electrical and Electronics & Communication Engg.

... further reduced for commercial facilities. Electricity must be generated, as and when it is needed since electricity cannot be stored virtually in the system. There is no difference between a transmission line and a distribution line except for the voltage level and power handling capability. Transm ...
AN3215
AN3215

IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE) e-ISSN: 2278-1676,p-ISSN: 2320-3331
IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE) e-ISSN: 2278-1676,p-ISSN: 2320-3331

... In co-operation of electric utilities and end users of electric power are increasing worried about the quality of power. Power quality can be defined as “any power problem maintained in voltage, current and frequency those results in failure or mal operation of the customer equipment” [1]. Addition ...
M24098107
M24098107

... power grids with lower voltage levels. A self-provided VCB model considering the electrical characteristics of VCBs is used to investigate the electrical stress (e.g., overvoltages) while the VCBs are switching. 1.1. Power Oscillations Power oscillations may occur in electrical power systems after d ...
- Saraswathi Velu College of Engineering
- Saraswathi Velu College of Engineering

... Any equipment based on semiconductor technology can be affected which includes all computers , telecommunications PBXs and key systems, automated manufacturing and design systems, computerized medical equipment and point of sale terminals. 14. Why are these transients or noise on the power line caus ...
Transformers
Transformers

Combined Power Oscillator using GaN HEMT
Combined Power Oscillator using GaN HEMT



... (HV) power converter is complex because of high leakage inductance and winding capacitance associated with the transformer. Since these parasitic components can easily be integrated as a part of resonant network, RCs are popularly applied for these applications. [1] Aims to develop a fast and effici ...
Reverse polarity and overvoltage protection
Reverse polarity and overvoltage protection

... It is possible to automatically disconnect a circuit when the input voltage exceeds a predefined level. This is different from parallel transient voltage suppressor and fuse. Blow fuses have the obvious problem of being a one-time devices. PTC resettable fuses tend to be slow and they can conduct si ...
Thomas Jan98.qxd
Thomas Jan98.qxd

NMS Series - power, Murata
NMS Series - power, Murata

PSURF-01M - Advantex
PSURF-01M - Advantex

... Drop-Out) regulator designed to produce low voltage drop (0.2-0.3 V) from input power supply voltage. This allows to suppress the ripple to 40-60 dB, and to provide significant decoupling of the sections between each other. Due to small voltage drop on the linear regulator, efficiency loss is neglig ...
g202 rev-16 manual
g202 rev-16 manual

... If your motor has 2mH of inductance, the equation would look as follows. 32 * (√2) = 45.12V (TERM. 3) COIL A Connect one motor winding to this terminal (TERM. 4) COIL /A Connect the other end of the winding to this terminal (TERM. 5) COIL B Connect the other motor winding to this terminal (TERM. 6) ...
PowerPoint
PowerPoint

Chapter 1.2 Basics of Energy and its various forms Part
Chapter 1.2 Basics of Energy and its various forms Part

... Explain the importance of TOD (time of the day) tariff? Many electrical utilities like to have flat demand curve to achieve high plant efficiency. They encourage user to draw more power during off-peak hours (say during night time) and less power during peak hours. As per their plan, they offer TOD ...
Electric Charges and Current AND Electricity and Magnetism In Our
Electric Charges and Current AND Electricity and Magnetism In Our

... many volts at one time. • A short circuit is a connection that allows current to take an unintentional path. ...
Keysight Technologies Power Conversion Efficiency Measurement
Keysight Technologies Power Conversion Efficiency Measurement

... and accurate efficiency measurements. These instruments typically have multiple isolated inputs to measure voltage and current simultaneously on the input and output of a power conversion device. The analyzer will multiply the voltage and current signals together and perform the integration of the r ...
Wind Turbine Generators (WTGs)
Wind Turbine Generators (WTGs)

...  the reserve requirements to meet reliability performance standards ...
Battery Voltage Boost Regulator
Battery Voltage Boost Regulator

... – Probably ok since problem was input voltage too low – And the output voltage is regulated • Input has capability for two fuses in parallel – Added by author in response to user requests – This can be risky since load sharing is not guaranteed • Why use 2.5V reference for comparator input when 5V w ...
Design_Logic_Probe
Design_Logic_Probe

... The logic probe should have three output LEDs. Only one LED at a time should light when the input is a steady DC level between zero and +5 V. – LED 1 should light when the input voltage is below 0.8 V. – LED 2 should light (a) when the input is open (floating) or (b) when the input voltage is betwee ...
Suntan® Su® DB101-THRU
Suntan® Su® DB101-THRU

... SINGLE-PHASE GLASS PASSIVATED SILICON SURFACE MOUNT BRIDGE RECTIFIER REVERSE VOLTAGE 50 to 1000 Volts FORWARD CURRENT 1.0 Ampere RATING AND CHARACTERISTIC CURVES DB101 THRU DB107 ...
< 1 ... 773 774 775 776 777 778 779 780 781 ... 1128 >

Power engineering



Power engineering, also called power systems engineering, is a subfield of energy engineering that deals with the generation, transmission, distribution and utilization of electric power and the electrical devices connected to such systems including generators, motors and transformers. Although much of the field is concerned with the problems of three-phase AC power – the standard for large-scale power transmission and distribution across the modern world – a significant fraction of the field is concerned with the conversion between AC and DC power and the development of specialized power systems such as those used in aircraft or for electric railway networks. It was a subfield of electrical engineering before the emergence of energy engineering.Electricity became a subject of scientific interest in the late 17th century with the work of William Gilbert. Over the next two centuries a number of important discoveries were made including the incandescent light bulb and the voltaic pile. Probably the greatest discovery with respect to power engineering came from Michael Faraday who in 1831 discovered that a change in magnetic flux induces an electromotive force in a loop of wire—a principle known as electromagnetic induction that helps explain how generators and transformers work.In 1881 two electricians built the world's first power station at Godalming in England. The station employed two waterwheels to produce an alternating current that was used to supply seven Siemens arc lamps at 250 volts and thirty-four incandescent lamps at 40 volts. However supply was intermittent and in 1882 Thomas Edison and his company, The Edison Electric Light Company, developed the first steam-powered electric power station on Pearl Street in New York City. The Pearl Street Station consisted of several generators and initially powered around 3,000 lamps for 59 customers. The power station used direct current and operated at a single voltage. Since the direct current power could not be easily transformed to the higher voltages necessary to minimise power loss during transmission, the possible distance between the generators and load was limited to around half-a-mile (800 m).That same year in London Lucien Gaulard and John Dixon Gibbs demonstrated the first transformer suitable for use in a real power system. The practical value of Gaulard and Gibbs' transformer was demonstrated in 1884 at Turin where the transformer was used to light up forty kilometres (25 miles) of railway from a single alternating current generator. Despite the success of the system, the pair made some fundamental mistakes. Perhaps the most serious was connecting the primaries of the transformers in series so that switching one lamp on or off would affect other lamps further down the line. Following the demonstration George Westinghouse, an American entrepreneur, imported a number of the transformers along with a Siemens generator and set his engineers to experimenting with them in the hopes of improving them for use in a commercial power system.One of Westinghouse's engineers, William Stanley, recognised the problem with connecting transformers in series as opposed to parallel and also realised that making the iron core of a transformer a fully enclosed loop would improve the voltage regulation of the secondary winding. Using this knowledge he built a much improved alternating current power system at Great Barrington, Massachusetts in 1886. In 1885 the Italian physicist and electrical engineer Galileo Ferraris demonstrated an induction motor and in 1887 and 1888 the Serbian-American engineer Nikola Tesla filed a range of patents related to power systems including one for a practical two-phase induction motor which Westinghouse licensed for his AC system.By 1890 the power industry had flourished and power companies had built thousands of power systems (both direct and alternating current) in the United States and Europe – these networks were effectively dedicated to providing electric lighting. During this time a fierce rivalry in the US known as the ""War of Currents"" emerged between Edison and Westinghouse over which form of transmission (direct or alternating current) was superior. In 1891, Westinghouse installed the first major power system that was designed to drive an electric motor and not just provide electric lighting. The installation powered a 100 horsepower (75 kW) synchronous motor at Telluride, Colorado with the motor being started by a Tesla induction motor. On the other side of the Atlantic, Oskar von Miller built a 20 kV 176 km three-phase transmission line from Lauffen am Neckar to Frankfurt am Main for the Electrical Engineering Exhibition in Frankfurt. In 1895, after a protracted decision-making process, the Adams No. 1 generating station at Niagara Falls began transmitting three-phase alternating current power to Buffalo at 11 kV. Following completion of the Niagara Falls project, new power systems increasingly chose alternating current as opposed to direct current for electrical transmission.Although the 1880s and 1890s were seminal decades in the field, developments in power engineering continued throughout the 20th and 21st century. In 1936 the first commercial high-voltage direct current (HVDC) line using mercury-arc valves was built between Schenectady and Mechanicville, New York. HVDC had previously been achieved by installing direct current generators in series (a system known as the Thury system) although this suffered from serious reliability issues. In 1957 Siemens demonstrated the first solid-state rectifier (solid-state rectifiers are now the standard for HVDC systems) however it was not until the early 1970s that this technology was used in commercial power systems. In 1959 Westinghouse demonstrated the first circuit breaker that used SF6 as the interrupting medium. SF6 is a far superior dielectric to air and, in recent times, its use has been extended to produce far more compact switching equipment (known as switchgear) and transformers. Many important developments also came from extending innovations in the ICT field to the power engineering field. For example, the development of computers meant load flow studies could be run more efficiently allowing for much better planning of power systems. Advances in information technology and telecommunication also allowed for much better remote control of the power system's switchgear and generators.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report