• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Stiletto - MESA/Boogie
Stiletto - MESA/Boogie

... 2.) The SOLO Control is activated when the Footswitch is connected to the FOOTSWITCH jack on the Rear Panel and the FX LOOP is activated. When the footswitch is not connected the SOLO Control will have no effect on the volume level. 3.) When the FX LOOP is activated it is normal to hear the volume d ...
TSFF5210
TSFF5210

PAM8013/PAM8015 Description Pin Assignments
PAM8013/PAM8015 Description Pin Assignments

... When input resistance variation is considered, the Ci is 7nF, so one would likely choose a value of 10nF. A further consideration for this capacitor is the leakage path from the input source through the input network (Ci, Ri + Rf) to the load. This leakage current creates a DC offset voltage at the ...
Power Supplies
Power Supplies

... When increasing the capacity, observe the following. 1. Maintain the operating temperature below 40ºC. 2. Output cannot be connected directly in parallel operation. Connect a diode to the output of each PS6R. 3. Output terminal voltage of both power supplies must be the same. Also, maintain the v ...
Mitigation of Magnetizing Inrush Current using Sequential Phase
Mitigation of Magnetizing Inrush Current using Sequential Phase

... M. Jamali, M. Mirzaie, S. Asghar-Gholamian. Mitigation of Magnetizing Inrush Current using Sequential Phase Energization Technique // Electronics and Electrical Engineering. – Kaunas: Technologija, 2011. – No. 2(108). – P. 67–70. Energization of a transformer under no load or lightly loaded conditio ...
Installation Manual Engineered Pump Systems (EPS)
Installation Manual Engineered Pump Systems (EPS)

DIPLOMAT LOGIC Manual
DIPLOMAT LOGIC Manual

... a. The thermostat is installed as a safety device to prevent overheating of the kettle if the machine is left unattended momentarily while in operation. The operation of the thermostat is indicated by the kettle indicator light. The indicator light should stay on for most of the popping cycle. The i ...
NTD20N03L27 - Power MOSFET, 20 A, 30 V, N
NTD20N03L27 - Power MOSFET, 20 A, 30 V, N

... are registered trademarks of Semiconductor Components Industries, LLC (SCILLC) or its subsidiaries in the United States and/or other countries. SCILLC owns the rights to a number of patents, trademarks, copyrights, trade secrets, and other intellectual property. A listing of SCILLC’s product/patent ...
designing concept on lightning protection of overhead power
designing concept on lightning protection of overhead power

... protection for high-voltage distribution lines, and the fruits of such labors have made their way into lightning protection design guidelines at different times. As research advances, the number of lightning outages has been steadily falling, but lightning outages still account for a high percentage ...
LTC3892/ - 60V Low IQ, Dual, 2-Phase Synchronous Step
LTC3892/ - 60V Low IQ, Dual, 2-Phase Synchronous Step

... Note 3: This IC includes overtemperature protection that is intended to protect the device during momentary overload conditions. The maximum rated junction temperature will be exceeded when this protection is active. Continuous operation above the specified absolute maximum operating junction temper ...
Operation Manual - Peak Beam Systems, Inc.
Operation Manual - Peak Beam Systems, Inc.

View Notification
View Notification

LAPP IPMC Mezzanine LAPP Intelligent Platform Management Controller Mezzanine Version V1.5
LAPP IPMC Mezzanine LAPP Intelligent Platform Management Controller Mezzanine Version V1.5

... Figure 3 shows the AMC management architecture on an ATCA board. The management bus IPMB-L is chained to all AMCs. This bus is controlled for each AMC by a buffer that can be enables or disabled by the IPMC in order to isolate the AMC. The IPMC receives the PS1# signal indicating that an AMC is conn ...
N2893A 100 MHz Current Probe
N2893A 100 MHz Current Probe

... noise and low circuit insertion loss. It also features the AutoProbe interface which makes current measurements as simple as those made with active voltage probes. The N2893A has two operating regions that provide a wide, flat frequency response. In the DC to low frequency AC region, the probe opera ...
39146132-Electrochemical-Machining-ECM
39146132-Electrochemical-Machining-ECM

... The power needed to operate the ECM is obviously electrical. There are many specifications to this power. The current density must be high. The gap between the tool and the work piece must be low for higher accuracy, thus the voltage must be low to avoid a short circuit. The control system uses some ...
LTM4616 - Dual 8A per Channel Low VIN DC/DC uModule
LTM4616 - Dual 8A per Channel Low VIN DC/DC uModule

... switch mode DC/DC power regulator system in a 15mm × 15mm surface mount LGA or BGA package. Included in the package are the switching controller, power FETs, inductor and all support components. Operating from an input voltage range of 2.7V to 5.5V, the LTM4616 supports two outputs within a voltage ...
LT8630 - 100V, 0.6A Synchronous Micropower
LT8630 - 100V, 0.6A Synchronous Micropower

... The LT8630 is a monolithic, variable frequency, current mode step-down DC/DC converter. When the voltage on the EN/UV pin is below its 1.19V threshold, the LT8630 is shutdown and draws less than 5µA from the input supply. When the EN/UV pin is driven above 1.19V, the internal bias circuits turn on g ...
horstmann gmbh
horstmann gmbh

GA-H81M-H - Gigabyte
GA-H81M-H - Gigabyte

High Voltage Engineering
High Voltage Engineering

... Europe and even in remote parts of the world, such as Kimberley in South Africa where electric street lights were switched on at the diamond mines on 1 September 1882 – three days before the commissioning of the Pearl Street Power Station in New York. It was soon realised that a low voltage power li ...
REMOTE AUTOMATIC FLARE IGNITION SYSTEM ELYXXON
REMOTE AUTOMATIC FLARE IGNITION SYSTEM ELYXXON

Damping of Power System Oscillations using Unified Power Flow
Damping of Power System Oscillations using Unified Power Flow

... I. INTRODUCTION The power transfer in an integrated power system is constrained by transient stability, voltage stability and small signal stability. These constraints limit a full utilization of available transmission corridors. Flexible AC Transmission System (FACTS) is the technology that provide ...
YORK SSS Style B Liquid Cooled Solid State Starter Operation
YORK SSS Style B Liquid Cooled Solid State Starter Operation

... Indicates a potentially hazardous situation which will result in possible injuries or damage to equipment if proper care is not taken. ...
12+ CUTMASTER
12+ CUTMASTER

... • Do not use the plasma torch in an area where combustible or explosive gases or materials are located. • Phosgene, a toxic gas, is generated from the vapors of chlorinated solvents and cleansers. Remove all sources of these ...
Floorizwarm Install Manual
Floorizwarm Install Manual

< 1 ... 71 72 73 74 75 76 77 78 79 ... 1128 >

Power engineering



Power engineering, also called power systems engineering, is a subfield of energy engineering that deals with the generation, transmission, distribution and utilization of electric power and the electrical devices connected to such systems including generators, motors and transformers. Although much of the field is concerned with the problems of three-phase AC power – the standard for large-scale power transmission and distribution across the modern world – a significant fraction of the field is concerned with the conversion between AC and DC power and the development of specialized power systems such as those used in aircraft or for electric railway networks. It was a subfield of electrical engineering before the emergence of energy engineering.Electricity became a subject of scientific interest in the late 17th century with the work of William Gilbert. Over the next two centuries a number of important discoveries were made including the incandescent light bulb and the voltaic pile. Probably the greatest discovery with respect to power engineering came from Michael Faraday who in 1831 discovered that a change in magnetic flux induces an electromotive force in a loop of wire—a principle known as electromagnetic induction that helps explain how generators and transformers work.In 1881 two electricians built the world's first power station at Godalming in England. The station employed two waterwheels to produce an alternating current that was used to supply seven Siemens arc lamps at 250 volts and thirty-four incandescent lamps at 40 volts. However supply was intermittent and in 1882 Thomas Edison and his company, The Edison Electric Light Company, developed the first steam-powered electric power station on Pearl Street in New York City. The Pearl Street Station consisted of several generators and initially powered around 3,000 lamps for 59 customers. The power station used direct current and operated at a single voltage. Since the direct current power could not be easily transformed to the higher voltages necessary to minimise power loss during transmission, the possible distance between the generators and load was limited to around half-a-mile (800 m).That same year in London Lucien Gaulard and John Dixon Gibbs demonstrated the first transformer suitable for use in a real power system. The practical value of Gaulard and Gibbs' transformer was demonstrated in 1884 at Turin where the transformer was used to light up forty kilometres (25 miles) of railway from a single alternating current generator. Despite the success of the system, the pair made some fundamental mistakes. Perhaps the most serious was connecting the primaries of the transformers in series so that switching one lamp on or off would affect other lamps further down the line. Following the demonstration George Westinghouse, an American entrepreneur, imported a number of the transformers along with a Siemens generator and set his engineers to experimenting with them in the hopes of improving them for use in a commercial power system.One of Westinghouse's engineers, William Stanley, recognised the problem with connecting transformers in series as opposed to parallel and also realised that making the iron core of a transformer a fully enclosed loop would improve the voltage regulation of the secondary winding. Using this knowledge he built a much improved alternating current power system at Great Barrington, Massachusetts in 1886. In 1885 the Italian physicist and electrical engineer Galileo Ferraris demonstrated an induction motor and in 1887 and 1888 the Serbian-American engineer Nikola Tesla filed a range of patents related to power systems including one for a practical two-phase induction motor which Westinghouse licensed for his AC system.By 1890 the power industry had flourished and power companies had built thousands of power systems (both direct and alternating current) in the United States and Europe – these networks were effectively dedicated to providing electric lighting. During this time a fierce rivalry in the US known as the ""War of Currents"" emerged between Edison and Westinghouse over which form of transmission (direct or alternating current) was superior. In 1891, Westinghouse installed the first major power system that was designed to drive an electric motor and not just provide electric lighting. The installation powered a 100 horsepower (75 kW) synchronous motor at Telluride, Colorado with the motor being started by a Tesla induction motor. On the other side of the Atlantic, Oskar von Miller built a 20 kV 176 km three-phase transmission line from Lauffen am Neckar to Frankfurt am Main for the Electrical Engineering Exhibition in Frankfurt. In 1895, after a protracted decision-making process, the Adams No. 1 generating station at Niagara Falls began transmitting three-phase alternating current power to Buffalo at 11 kV. Following completion of the Niagara Falls project, new power systems increasingly chose alternating current as opposed to direct current for electrical transmission.Although the 1880s and 1890s were seminal decades in the field, developments in power engineering continued throughout the 20th and 21st century. In 1936 the first commercial high-voltage direct current (HVDC) line using mercury-arc valves was built between Schenectady and Mechanicville, New York. HVDC had previously been achieved by installing direct current generators in series (a system known as the Thury system) although this suffered from serious reliability issues. In 1957 Siemens demonstrated the first solid-state rectifier (solid-state rectifiers are now the standard for HVDC systems) however it was not until the early 1970s that this technology was used in commercial power systems. In 1959 Westinghouse demonstrated the first circuit breaker that used SF6 as the interrupting medium. SF6 is a far superior dielectric to air and, in recent times, its use has been extended to produce far more compact switching equipment (known as switchgear) and transformers. Many important developments also came from extending innovations in the ICT field to the power engineering field. For example, the development of computers meant load flow studies could be run more efficiently allowing for much better planning of power systems. Advances in information technology and telecommunication also allowed for much better remote control of the power system's switchgear and generators.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report