• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
EB-200 ELECTRIC DROPBOLT
EB-200 ELECTRIC DROPBOLT

to U217B datasheet.
to U217B datasheet.

... Ramp voltage available at capacitor C2 is decoupled across emitter follower at Pin l. To maintain the lamp flicker specification, ramp duration is adjusted according to the controlling load. In practice, interference should be avoided (temperature control). Therefore in such cases a two point contro ...
EEA018-lecture
EEA018-lecture

... Figure 14.4 Fibrillation current versus shock duration. Thresholds for ventricular fibrillation in animals for 60 Hz ac current. Duration of current (0.2 to 5 s) and weight of animal body were varied. (From L. A. Geddes, IEEE Trans. Biomed. Eng., 1973, 20, 465-468. Copyright 1973 by the Institute of ...
iew rev Book 93
iew rev Book 93

... starts with an Introduction chapter ...
Fusion Datasheet.indd - Control Concepts, Inc.
Fusion Datasheet.indd - Control Concepts, Inc.

... * Other scaling options available via control panel software. Contact factory for information. ** User selectable. Feature may be disabled in case of nuisance shorted SCR warnings These Marks are registered by Underwriters Laboratories Inc. ...
View Activity Guide Preview
View Activity Guide Preview

ADVANCED ELECTRICAL SAFETY AWARENESS February 9, 2008
ADVANCED ELECTRICAL SAFETY AWARENESS February 9, 2008

... Prevent overloaded wiring by using the right size and type of wire. Prevent exposure to live electrical parts by isolating them. Prevent exposure to live wires and parts by using insulation. Prevent shocking currents from electrical systems & tools by ...
TSM17C Hardware Manual
TSM17C Hardware Manual

... maximum. When operating below 18 VDC, the power supply input may require larger capacitance to prevent under-voltage and internal-supply alarms. Current spikes may make supply readings erratic. The supply input cannot go below 10 VDC for reliable operation. Absolute minimum power supply input is 10 ...
Weston 4 Interim Relay Requirements
Weston 4 Interim Relay Requirements

... While DGA does not tell the whole story of a transformer’s health, it can give a signal that something is happening that may need further inspection, perhaps even an internal visual inspection. In some parts of the grid operating procedures alone may still not be sufficient to prevent large scale bl ...
Test Instrumentation & Automated Test Systems Power Conversion Hipot / Safety Component
Test Instrumentation & Automated Test Systems Power Conversion Hipot / Safety Component

... Hipot, Insulation Resistance, Ground Bond, Leakage Current and Dynamic Function tests for compliance testing of IEC, UL, TUV, CSA, EN and other standards. The time-saving TwinPort™ feature performs Hipot and Ground Bond simultaneously cutting time for these tests in half. The 19032 also has an open ...
Electronic Engineering Department, Universitat Politècnica de Catalunya, Barcelona, Spain {mateo, pepaltet,
Electronic Engineering Department, Universitat Politècnica de Catalunya, Barcelona, Spain {mateo, pepaltet,

... temperature corresponding to dissipations at this so high frequencies (some works have reported thermal measurements corresponding to powers dissipated up to 100 KHz [3]). But if f2 - f1 is small enough, it will be possible to estimate the power dissipated at this low frequency, which as we show in ...
Berg Heinz-Peter, Fritze Nicole Reliability and vulnerability of
Berg Heinz-Peter, Fritze Nicole Reliability and vulnerability of

... use, i.e. 415 V (3-phase) or 240 V (1-phase) at distribution substations adjacent to the residential, commercial and small to medium industrial customers in the US, in Europe the transmission voltage is reduced to 400 V or 230 V. Figure 1 shows a typical electrical network system, in which power is ...
Low Voltage Power Circuit Breaker
Low Voltage Power Circuit Breaker

... Zone-Selective Interlocking (ZSI), or zone restraint, has been available since the early 1990s. ZSI is designed to limit thermal stress caused by shortcircuits on a distribution system. ZSI will enhance the coordination of the upstream and downstream molded case circuit breakers for all values of av ...
1N5817
1N5817

Series/Parallel Resistor Reduction
Series/Parallel Resistor Reduction

... CAN BE ANALYZED WITH ONE APPLICATION OF KVL(SINGLE LOOP) OR KCL(SINGLE NODE-PAIR) WE HAVE ALSO SEEN THAT IN SOME SITUATIONS IT IS ADVANTAGEOUS TO COMBINE RESISTORS TO SIMPLIFY THE ANALYSIS OF A CIRCUIT NOW WE EXAMINE SOME MORE COMPLEX CIRCUITS WHERE WE CAN SIMPLIFY THE ANALYSIS USING THE TECHNIQUE O ...
Chap 4 Methods of Analysis
Chap 4 Methods of Analysis

... An ideal voltage source is independent of the current through it. A (more) practical voltage source is modeled by an ideal voltage source in series with a resistor. This more closely approximates “real” voltage sources.  Ideal -vs- Practical Current Source An ideal current source is independent of ...
Optimal Power Flow using Hybrid Intelligent Algorithm
Optimal Power Flow using Hybrid Intelligent Algorithm

... Optimal Power Flow (OPF) is the important for operation and planning of the power system. The OPF results are used in operation to improve the quality and generation cost of the power system. In planning the results of OPF is used to forecast future electric load expansion based on past and current ...
Power Factor Correction for Power Systems Power Factor Correction
Power Factor Correction for Power Systems Power Factor Correction

... would be necessary with zero reactance in the circuit to deliver the same amount of (true) power to the resistive load. The poor power factor makes for an inefficient power delivery system. Poor power factor can be corrected, paradoxically, by adding another load to the circuit drawing an equal and ...
Series/Parallel Resistor Reduction
Series/Parallel Resistor Reduction

... CAN BE ANALYZED WITH ONE APPLICATION OF KVL(SINGLE LOOP) OR KCL(SINGLE NODE-PAIR) WE HAVE ALSO SEEN THAT IN SOME SITUATIONS IT IS ADVANTAGEOUS TO COMBINE RESISTORS TO SIMPLIFY THE ANALYSIS OF A CIRCUIT NOW WE EXAMINE SOME MORE COMPLEX CIRCUITS WHERE WE CAN SIMPLIFY THE ANALYSIS USING THE TECHNIQUE O ...
PPT - School of Engineering and Applied Science
PPT - School of Engineering and Applied Science

... • Report numerical values of your results in tabular form. • Can we vary the width of NMOS instead of PMOS in order to obtain symmetric VTC? If yes, should we increase or decrease it’s value keeping PMOS width fixed? • On the VTC of the inverter show the triode, saturation and cut off region. Which ...
High Efficient Bidirectional Battery Converter for Residential PV Systems Cam Pham Tamas Kerekes
High Efficient Bidirectional Battery Converter for Residential PV Systems Cam Pham Tamas Kerekes

... switching frequency is decided by the inductor design, for IDPSBBC switch with 200 kHz. An inductance of 602 µH is required to handle 750W and can operate in CCM down to 10% of the nominal load. For the required inductance on an ETD34 cores, 85 turns are needed. With litz wire of type 32x0.1mm as wi ...
SmartPro 208/120V 5kVA 4kW Line-Interactive Sine Wave
SmartPro 208/120V 5kVA 4kW Line-Interactive Sine Wave

... 8 customized load management receptacles can be individually powered off and back on again via software interface to reboot remote equipment or perform "load shedding" of less critical loads to extend battery runtime for the most critical equipment Emergency Power Off (EPO) interface for emergency s ...
Lab-3: Squirrel-Cage Induction Motor Xm Xl R  R Xl s
Lab-3: Squirrel-Cage Induction Motor Xm Xl R R Xl s

... transient appear on the screen click on the PAUSE button on the program interface. Once the transient is captured on the PC screen you may be able to zoom into the representative part of the transient that includes only few cycles (before) after the steady-state is reached. Then save the data file b ...
PowerPad Model 8333 Data Sheet
PowerPad Model 8333 Data Sheet

... Display waveforms, trend graphs, harmonic spectrums, text summaries, transients, event logs and stored alarms Print reports using standard or custom t­emplates you design Free updates are available on our website www.aemc.com ...
IOSR Journal of Electrical and Electronics Engineering(IOSR-JEEE) e-ISSN: 2278-1676, p-ISSN: 2320-3331
IOSR Journal of Electrical and Electronics Engineering(IOSR-JEEE) e-ISSN: 2278-1676, p-ISSN: 2320-3331

... for low-power VLSI can be addressed at different design levels, such as the architectural, circuit, layout, and the process technology level [3]. The power can significant be reduced at the circuit design level by means of proper choice of a design style for implementing combinational circuits. This ...
< 1 ... 714 715 716 717 718 719 720 721 722 ... 1128 >

Power engineering



Power engineering, also called power systems engineering, is a subfield of energy engineering that deals with the generation, transmission, distribution and utilization of electric power and the electrical devices connected to such systems including generators, motors and transformers. Although much of the field is concerned with the problems of three-phase AC power – the standard for large-scale power transmission and distribution across the modern world – a significant fraction of the field is concerned with the conversion between AC and DC power and the development of specialized power systems such as those used in aircraft or for electric railway networks. It was a subfield of electrical engineering before the emergence of energy engineering.Electricity became a subject of scientific interest in the late 17th century with the work of William Gilbert. Over the next two centuries a number of important discoveries were made including the incandescent light bulb and the voltaic pile. Probably the greatest discovery with respect to power engineering came from Michael Faraday who in 1831 discovered that a change in magnetic flux induces an electromotive force in a loop of wire—a principle known as electromagnetic induction that helps explain how generators and transformers work.In 1881 two electricians built the world's first power station at Godalming in England. The station employed two waterwheels to produce an alternating current that was used to supply seven Siemens arc lamps at 250 volts and thirty-four incandescent lamps at 40 volts. However supply was intermittent and in 1882 Thomas Edison and his company, The Edison Electric Light Company, developed the first steam-powered electric power station on Pearl Street in New York City. The Pearl Street Station consisted of several generators and initially powered around 3,000 lamps for 59 customers. The power station used direct current and operated at a single voltage. Since the direct current power could not be easily transformed to the higher voltages necessary to minimise power loss during transmission, the possible distance between the generators and load was limited to around half-a-mile (800 m).That same year in London Lucien Gaulard and John Dixon Gibbs demonstrated the first transformer suitable for use in a real power system. The practical value of Gaulard and Gibbs' transformer was demonstrated in 1884 at Turin where the transformer was used to light up forty kilometres (25 miles) of railway from a single alternating current generator. Despite the success of the system, the pair made some fundamental mistakes. Perhaps the most serious was connecting the primaries of the transformers in series so that switching one lamp on or off would affect other lamps further down the line. Following the demonstration George Westinghouse, an American entrepreneur, imported a number of the transformers along with a Siemens generator and set his engineers to experimenting with them in the hopes of improving them for use in a commercial power system.One of Westinghouse's engineers, William Stanley, recognised the problem with connecting transformers in series as opposed to parallel and also realised that making the iron core of a transformer a fully enclosed loop would improve the voltage regulation of the secondary winding. Using this knowledge he built a much improved alternating current power system at Great Barrington, Massachusetts in 1886. In 1885 the Italian physicist and electrical engineer Galileo Ferraris demonstrated an induction motor and in 1887 and 1888 the Serbian-American engineer Nikola Tesla filed a range of patents related to power systems including one for a practical two-phase induction motor which Westinghouse licensed for his AC system.By 1890 the power industry had flourished and power companies had built thousands of power systems (both direct and alternating current) in the United States and Europe – these networks were effectively dedicated to providing electric lighting. During this time a fierce rivalry in the US known as the ""War of Currents"" emerged between Edison and Westinghouse over which form of transmission (direct or alternating current) was superior. In 1891, Westinghouse installed the first major power system that was designed to drive an electric motor and not just provide electric lighting. The installation powered a 100 horsepower (75 kW) synchronous motor at Telluride, Colorado with the motor being started by a Tesla induction motor. On the other side of the Atlantic, Oskar von Miller built a 20 kV 176 km three-phase transmission line from Lauffen am Neckar to Frankfurt am Main for the Electrical Engineering Exhibition in Frankfurt. In 1895, after a protracted decision-making process, the Adams No. 1 generating station at Niagara Falls began transmitting three-phase alternating current power to Buffalo at 11 kV. Following completion of the Niagara Falls project, new power systems increasingly chose alternating current as opposed to direct current for electrical transmission.Although the 1880s and 1890s were seminal decades in the field, developments in power engineering continued throughout the 20th and 21st century. In 1936 the first commercial high-voltage direct current (HVDC) line using mercury-arc valves was built between Schenectady and Mechanicville, New York. HVDC had previously been achieved by installing direct current generators in series (a system known as the Thury system) although this suffered from serious reliability issues. In 1957 Siemens demonstrated the first solid-state rectifier (solid-state rectifiers are now the standard for HVDC systems) however it was not until the early 1970s that this technology was used in commercial power systems. In 1959 Westinghouse demonstrated the first circuit breaker that used SF6 as the interrupting medium. SF6 is a far superior dielectric to air and, in recent times, its use has been extended to produce far more compact switching equipment (known as switchgear) and transformers. Many important developments also came from extending innovations in the ICT field to the power engineering field. For example, the development of computers meant load flow studies could be run more efficiently allowing for much better planning of power systems. Advances in information technology and telecommunication also allowed for much better remote control of the power system's switchgear and generators.