• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Open Loop Control Of Series Parallel Resonant Converter
Open Loop Control Of Series Parallel Resonant Converter

Lecture Notes EEE 360
Lecture Notes EEE 360

... DC Generator Equivalent circuit • The magnetic field produced by the stator poles induces a voltage in the rotor (or armature) coils when the generator is rotated. • This induced voltage is represented by a voltage source. • The stator coil has resistance, which is connected in series. • The pole f ...
Catalog News LV 1 N 06/2008 EN
Catalog News LV 1 N 06/2008 EN

... The SENTRON PAC3200 is a control panel instrument for measuring and indicating more than 50 electric power distribution variables such as voltage, current, power, electrical work and frequency with their minimum, maximum and mean values. It convinces through its compact design and high performance c ...
a survey and study of different types of pwm
a survey and study of different types of pwm

... SVPWM technique was orig inally developed as a vector approach to pulse width modulation for three-phase inverters. The SVPWM method is frequently used in vector controlled applications. In vector controlled applications this technique is used for reference voltage generation when current control is ...
Figure 7. 51.8 Volt Battery and PCM Maxwell
Figure 7. 51.8 Volt Battery and PCM Maxwell

... hypotheses. This is when we involved the Voice of the Customer to develop the Customer Critical Requirements. We listened to our facilitator’s and sponsor’s needs as we asked them probing questions. In compiling the answers we received, we were able to create our design specifications (which are lis ...
Document
Document

... Thyristor in a Simple Circuit ...
IMX8
IMX8

... otherwise dispose of the same, no express or implied right or license to practice or commercially exploit any intellectual property rights or other proprietary rights owned or controlled by ROHM CO., LTD. is granted to any such buyer. Products listed in this document are no antiradiation design. ...
EMDX3 electrical energy meters EMDX3 multi
EMDX3 electrical energy meters EMDX3 multi

... EMDX3 - Premium (continued) Modules for EMDX3 - Premium multi-function measuring units RS 485 communication module MODBUS link Storage module Storage of active and reactive power over 62 days, the last 10 alarms and the average voltage and frequency values over 60 days max. Module with 2 inputs/2 ou ...
QUALITROL-IRIS POWER IS THE WORLD’S LARGEST PROVIDER OF MONITORING AND
QUALITROL-IRIS POWER IS THE WORLD’S LARGEST PROVIDER OF MONITORING AND

... Generator stator endwinding vibration can lead to machine failure if it is not caught at an early stage. Nonmetallic accelerometers are required to measure and trend this endwinding vibration. Iris Power supplies reliable endwinding accelerometers based on fiber optic technology. These sensors are p ...
Basic Electricity Homework
Basic Electricity Homework

... current through it of 2.5 amperes. Calculate the resistance of the resistor. 2. A voltage of 6 volts is across a resistor where the current is 0.5 amperes. What is the value of the resistor? 3. Calculate the resistance of a component when a voltage of 24 V causes a current of 0.1 amperes. 4. If a cu ...
MODEL 2681 Voltage Band Monitor
MODEL 2681 Voltage Band Monitor

Tip120 - Adafruit
Tip120 - Adafruit

... A critical component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness. ...
CHAPTER-2
CHAPTER-2

... building must be appointed. • When a short or lightning occurs, energy flows to the ground, protecting you from electrical shock, injury and death • Grounded, permanently connected to earth through a ground connection of sufficiently low impedance and having sufficient capacity that ground fault cur ...
Wireless Rapid Charger of Super Capacitor
Wireless Rapid Charger of Super Capacitor

... wireless charge technology could be used. It will be opened from the trouble when the plug is connected by the hand by this technology. We have been researching the wireless power transmission that uses the resonance technology for the half bridge inverter and the noncontact transformer [8]. However ...
talk_FT_1_3
talk_FT_1_3

... • ANSYS model shows flexipivot now remains cool. • Small "hot spot" at base of thicker wedge is lower in temperature; will be further lowered by fabricating from Ni • Wedges (installed top and bottom) do not interfere with mechanics of flexipivot ...
DN444 - Ideal Diodes Protect Against Power Supply Wiring Errors
DN444 - Ideal Diodes Protect Against Power Supply Wiring Errors

... reliability. ORing diodes join the feeds together at the point of load, most often using Schottky diodes for low loss. MOSFET-based ideal diodes can be used to replace Schottky diodes for a significant reduction in power dissipation, simplifying the thermal layout and improving system efficiency. Figu ...
J.M. Rivas, T.A. Keim, and D.J. Perreault, “Performance Improvement of Alternators with Switched-Mode Rectifiers,” IEEE Transactions on Energy Conversion , Vol. 19, No. 3, Sept. 2004, pp. 561-568.
J.M. Rivas, T.A. Keim, and D.J. Perreault, “Performance Improvement of Alternators with Switched-Mode Rectifiers,” IEEE Transactions on Energy Conversion , Vol. 19, No. 3, Sept. 2004, pp. 561-568.

the use of protective earth as a distributor of fields and radiation
the use of protective earth as a distributor of fields and radiation

IOSR Journal of VLSI and Signal Processing (IOSR-JVSP)
IOSR Journal of VLSI and Signal Processing (IOSR-JVSP)

... consumption in a CMOS circuit occurs only when it is switching between logic levels. This power dissipation during a switching action is known as 'dynamic power'. Aside from low power consumption, CMOS circuits are also easy and cheap to fabricate, allowing denser circuit integration than their bipo ...
Wind Energy Conversion System from Electrical Perspective—A
Wind Energy Conversion System from Electrical Perspective—A

... the four existing in the current market and the two newer concepts discussed in the previous section are summarised in Table 1 [6-21,24,25]. Based on the information in Table 1, Table 2 represents a comparison of those six concepts with respect to the five criteria; energy yield, cost, reliability, ...
Kirchoff`s Rules
Kirchoff`s Rules

Simplify Multiple Bias Voltage Sequencing and
Simplify Multiple Bias Voltage Sequencing and

... mainframe digital I/O port provided a convenient means of generating the PW-OK output signal without any extra equipment. An extra slot is available in each of the mainframes for adding another module. This could be used as another output or paralleled with an existing output for greater power, if d ...
“Fuzzy Logic Speed Controllers Using FPGA Technique For Three
“Fuzzy Logic Speed Controllers Using FPGA Technique For Three

1 - Wyoming Public Service Commission
1 - Wyoming Public Service Commission

... (e) that the location of the facility as proposed conforms to applicable state and local laws and regulations, except that the department may refuse to apply any local law or regulation if it finds that, as applied to the proposed facility, the law or regulation is unreasonably restrictive in view ...
Control of High Speed Permanent Magnet Synchronous Motors
Control of High Speed Permanent Magnet Synchronous Motors

...  V/Hz drives typically add a low frequency voltage boost to increase starting torque capability  V/Hz drives typically add a steady state slip compensation which increases with frequency based on current measurement to give better steady state speed regulation  V/Hz drives may also add stability ...
< 1 ... 658 659 660 661 662 663 664 665 666 ... 1128 >

Power engineering



Power engineering, also called power systems engineering, is a subfield of energy engineering that deals with the generation, transmission, distribution and utilization of electric power and the electrical devices connected to such systems including generators, motors and transformers. Although much of the field is concerned with the problems of three-phase AC power – the standard for large-scale power transmission and distribution across the modern world – a significant fraction of the field is concerned with the conversion between AC and DC power and the development of specialized power systems such as those used in aircraft or for electric railway networks. It was a subfield of electrical engineering before the emergence of energy engineering.Electricity became a subject of scientific interest in the late 17th century with the work of William Gilbert. Over the next two centuries a number of important discoveries were made including the incandescent light bulb and the voltaic pile. Probably the greatest discovery with respect to power engineering came from Michael Faraday who in 1831 discovered that a change in magnetic flux induces an electromotive force in a loop of wire—a principle known as electromagnetic induction that helps explain how generators and transformers work.In 1881 two electricians built the world's first power station at Godalming in England. The station employed two waterwheels to produce an alternating current that was used to supply seven Siemens arc lamps at 250 volts and thirty-four incandescent lamps at 40 volts. However supply was intermittent and in 1882 Thomas Edison and his company, The Edison Electric Light Company, developed the first steam-powered electric power station on Pearl Street in New York City. The Pearl Street Station consisted of several generators and initially powered around 3,000 lamps for 59 customers. The power station used direct current and operated at a single voltage. Since the direct current power could not be easily transformed to the higher voltages necessary to minimise power loss during transmission, the possible distance between the generators and load was limited to around half-a-mile (800 m).That same year in London Lucien Gaulard and John Dixon Gibbs demonstrated the first transformer suitable for use in a real power system. The practical value of Gaulard and Gibbs' transformer was demonstrated in 1884 at Turin where the transformer was used to light up forty kilometres (25 miles) of railway from a single alternating current generator. Despite the success of the system, the pair made some fundamental mistakes. Perhaps the most serious was connecting the primaries of the transformers in series so that switching one lamp on or off would affect other lamps further down the line. Following the demonstration George Westinghouse, an American entrepreneur, imported a number of the transformers along with a Siemens generator and set his engineers to experimenting with them in the hopes of improving them for use in a commercial power system.One of Westinghouse's engineers, William Stanley, recognised the problem with connecting transformers in series as opposed to parallel and also realised that making the iron core of a transformer a fully enclosed loop would improve the voltage regulation of the secondary winding. Using this knowledge he built a much improved alternating current power system at Great Barrington, Massachusetts in 1886. In 1885 the Italian physicist and electrical engineer Galileo Ferraris demonstrated an induction motor and in 1887 and 1888 the Serbian-American engineer Nikola Tesla filed a range of patents related to power systems including one for a practical two-phase induction motor which Westinghouse licensed for his AC system.By 1890 the power industry had flourished and power companies had built thousands of power systems (both direct and alternating current) in the United States and Europe – these networks were effectively dedicated to providing electric lighting. During this time a fierce rivalry in the US known as the ""War of Currents"" emerged between Edison and Westinghouse over which form of transmission (direct or alternating current) was superior. In 1891, Westinghouse installed the first major power system that was designed to drive an electric motor and not just provide electric lighting. The installation powered a 100 horsepower (75 kW) synchronous motor at Telluride, Colorado with the motor being started by a Tesla induction motor. On the other side of the Atlantic, Oskar von Miller built a 20 kV 176 km three-phase transmission line from Lauffen am Neckar to Frankfurt am Main for the Electrical Engineering Exhibition in Frankfurt. In 1895, after a protracted decision-making process, the Adams No. 1 generating station at Niagara Falls began transmitting three-phase alternating current power to Buffalo at 11 kV. Following completion of the Niagara Falls project, new power systems increasingly chose alternating current as opposed to direct current for electrical transmission.Although the 1880s and 1890s were seminal decades in the field, developments in power engineering continued throughout the 20th and 21st century. In 1936 the first commercial high-voltage direct current (HVDC) line using mercury-arc valves was built between Schenectady and Mechanicville, New York. HVDC had previously been achieved by installing direct current generators in series (a system known as the Thury system) although this suffered from serious reliability issues. In 1957 Siemens demonstrated the first solid-state rectifier (solid-state rectifiers are now the standard for HVDC systems) however it was not until the early 1970s that this technology was used in commercial power systems. In 1959 Westinghouse demonstrated the first circuit breaker that used SF6 as the interrupting medium. SF6 is a far superior dielectric to air and, in recent times, its use has been extended to produce far more compact switching equipment (known as switchgear) and transformers. Many important developments also came from extending innovations in the ICT field to the power engineering field. For example, the development of computers meant load flow studies could be run more efficiently allowing for much better planning of power systems. Advances in information technology and telecommunication also allowed for much better remote control of the power system's switchgear and generators.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report