• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
tunnel solution - Shreelight Power Pvt. Ltd.
tunnel solution - Shreelight Power Pvt. Ltd.

... and adjustable: choice of 2 tones, adjustment of noise level Light sources fully interchangeable: incandescent bulbs, Super Bright LED with steady or flashing light, "Flash" discharge tubes on Ba15d base fitting Modular units stack vertically by simply interlocking and electrical connections between ...
ETSO-C174
ETSO-C174

... (i) The BEPU will not discharge through the input side of the BEPU. (j) If the BEPU provides backup power to multiple loads, equip the BEPU with protection provisions that allow for the isolation and removal of excess load on any of its output feeders that draw more than its pre-determined maximum c ...
1U Chassis Installation Guide
1U Chassis Installation Guide

... front or rear of the chassis are obstructed. Installation in a rack should be such that the airflow required for safe operation is not compromised. When rack mounted in a closed or multi-unit cabinet, the operating environment of the cabinet may be greater than the room ambient. In this case conside ...
60 mins Mains electricity exam Qs B+ with
60 mins Mains electricity exam Qs B+ with

... the RCD is switched on. An electronic circuit in the RCD monitors the difference between the current in the live wire and the current in the neutral wire. If something goes wrong and this difference is greater than 30 milliamps then the RCD will trip (= switch off) within 40 milliseconds. ...
Adaptive Multi-Band Multi-Mode Power Amplifier Using Integrated Varactor-Based Tunable Matching Networks
Adaptive Multi-Band Multi-Mode Power Amplifier Using Integrated Varactor-Based Tunable Matching Networks

... In linearity-focused research, the circuit is designed so that the resulting overall linearity performance of the PA module is improved. In this way, the active device can be operated closer to its peak-power capabilities and still be able to meet the linearity requirements. Pre-distortion is one te ...
International Electrical Engineering Journal (IEEJ) Vol. 5 (2014) No.10, pp. 1586-1593
International Electrical Engineering Journal (IEEJ) Vol. 5 (2014) No.10, pp. 1586-1593

... Restorer) and UPQC (Unified Power Quality Conditioner) [2]. The DSTATCOM is a shunt-active power filter connected in distribution system. It injects harmonic and reactive component of load current such that the unbalanced, harmonic, and reactive loads are converted into balanced linear resistive loa ...
JV3617051708
JV3617051708

... mobile batteries of different manufacturers using wind power, human power and electrical power has been designed for travelers, rural and remote areas where the current supply is not available all the time. This paper is very useful in today’s life because now days the necessity of communication is ...
Aalborg Universitet
Aalborg Universitet

... vigorously developed, wind turbine technology has being undergoing a dramatic development and now is the world’s fastest growing energy [1]. The future trend of wind energy conversion systems is to increase the power capacity of wind turbines and generators to reduce the cost of generated electricit ...
B) Indirect effects - Academic Science,International Journal of
B) Indirect effects - Academic Science,International Journal of

HI-102 Guide for the Installation, Operation, and Maintenance of
HI-102 Guide for the Installation, Operation, and Maintenance of

... link disconnects the transformer from the line without affecting line fuses or breakers. Lightning Arresters—Conventional transformers should be protected by properly rated lightning arresters. Ground connections on the arresters should be made before connection to the highvoltage line is made. On H ...
Surge Protection for Surveillance Systems
Surge Protection for Surveillance Systems

... equipment as well. DVRs, interior cameras, midspans and power supplies may not have received the initial surge, but because these components are connected, the entire system is at risk of damage or even destruction. 2. Install surge protection devices directly on the electrical service panel, along ...
1 - Mirus International Inc.
1 - Mirus International Inc.

... output Harmony-1E™ models are optional]. The transformer rating shall be the same as the continuous duty maximum full load rating of the HMPC. .2 The HMT shall be designed to eliminate the harmful effects of all the low frequency odd order harmonic currents generated by non-linear loads, such as com ...
Comparative Analysis of Series and Parallel Photovoltaic Arrays
Comparative Analysis of Series and Parallel Photovoltaic Arrays

... Photovoltaic (PV) systems have been the fastest growing energy technology over the last decade. This technology is been disseminated in residential applications employing underutilized spaces on rooftops [1]. Many different topologies of PV systems have been developed for residential applications, s ...
RURD4120S9A_F085 4A, 1200V Ultrafast Diodes Features
RURD4120S9A_F085 4A, 1200V Ultrafast Diodes Features

... Counterfeiting of semiconductor parts is a growing problem in the industry. All manufactures of semiconductor products are experiencing counterfeiting of their parts. Customers who inadvertently purchase counterfeit parts experience many problems such as loss of brand reputation, substandard perform ...
Unit 6 PowerPoint Slides
Unit 6 PowerPoint Slides

... In many cases, we can think of an electrical system as being composed of a source of power and a load connected to that source. Examples of sources: amplifier, generator, power supply. Examples of loads: loudspeaker, electric motor, antenna. ...
COOPER LIGHTING - SURE-LITES Catalog # Type ®
COOPER LIGHTING - SURE-LITES Catalog # Type ®

... For applications where the finest architectural appearance is required, the Concealed Emergency Light (CEL) Series offers the maximum protection of high quality MR16 lamps to light your path when you need it, but also the minimal intrusion on your environment when you don't. The CEL is fully recesse ...
distribution network
distribution network

... process with the supervision of the electrical plant which supplies it is becoming increasingly important. ...
lecture3 - WordPress.com
lecture3 - WordPress.com

A New Strained-Silicon Channel Trench
A New Strained-Silicon Channel Trench

distribution network
distribution network

... process with the supervision of the electrical plant which supplies it is becoming increasingly important. ...
MAX845 Isolated Transformer Driver for PCMCIA Applications _______________General Description
MAX845 Isolated Transformer Driver for PCMCIA Applications _______________General Description

... other height- and/or space-sensitive applications. It drives a center-tapped transformer primary from a 5V or 3.3V DC power supply. The secondary can be wound to provide any isolated DC voltage needed at power levels up to 750mW. The 450kHz minimum switching frequency allows the use of very thin tra ...
IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE)
IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE)

... uses a full voltage – source IGBT converter configuration is still under investigation [11]–[12] and not widely adopted by the wind power industry. The direct-current vector control technology is a vector control technology that has been developed recently to control the synchronous generator only i ...
Appendix A - University of Toronto Physics
Appendix A - University of Toronto Physics

K - thermengr.com
K - thermengr.com

... After KP has been determined, the same measurement setup can be used to determine junction temperature rise under DC steady-state conditions. Power output (POi) is measured the instant the DC power is applied and then ...
3 - Unitronics
3 - Unitronics

... a particular purpose, or non-infringement. Unitronics assumes no responsibility for errors or omissions in the information presented in this document. In no event shall Unitronics be liable for any special, incidental, indirect or consequential damages of any kind, or any damages whatsoever arising ...
< 1 ... 463 464 465 466 467 468 469 470 471 ... 1128 >

Power engineering



Power engineering, also called power systems engineering, is a subfield of energy engineering that deals with the generation, transmission, distribution and utilization of electric power and the electrical devices connected to such systems including generators, motors and transformers. Although much of the field is concerned with the problems of three-phase AC power – the standard for large-scale power transmission and distribution across the modern world – a significant fraction of the field is concerned with the conversion between AC and DC power and the development of specialized power systems such as those used in aircraft or for electric railway networks. It was a subfield of electrical engineering before the emergence of energy engineering.Electricity became a subject of scientific interest in the late 17th century with the work of William Gilbert. Over the next two centuries a number of important discoveries were made including the incandescent light bulb and the voltaic pile. Probably the greatest discovery with respect to power engineering came from Michael Faraday who in 1831 discovered that a change in magnetic flux induces an electromotive force in a loop of wire—a principle known as electromagnetic induction that helps explain how generators and transformers work.In 1881 two electricians built the world's first power station at Godalming in England. The station employed two waterwheels to produce an alternating current that was used to supply seven Siemens arc lamps at 250 volts and thirty-four incandescent lamps at 40 volts. However supply was intermittent and in 1882 Thomas Edison and his company, The Edison Electric Light Company, developed the first steam-powered electric power station on Pearl Street in New York City. The Pearl Street Station consisted of several generators and initially powered around 3,000 lamps for 59 customers. The power station used direct current and operated at a single voltage. Since the direct current power could not be easily transformed to the higher voltages necessary to minimise power loss during transmission, the possible distance between the generators and load was limited to around half-a-mile (800 m).That same year in London Lucien Gaulard and John Dixon Gibbs demonstrated the first transformer suitable for use in a real power system. The practical value of Gaulard and Gibbs' transformer was demonstrated in 1884 at Turin where the transformer was used to light up forty kilometres (25 miles) of railway from a single alternating current generator. Despite the success of the system, the pair made some fundamental mistakes. Perhaps the most serious was connecting the primaries of the transformers in series so that switching one lamp on or off would affect other lamps further down the line. Following the demonstration George Westinghouse, an American entrepreneur, imported a number of the transformers along with a Siemens generator and set his engineers to experimenting with them in the hopes of improving them for use in a commercial power system.One of Westinghouse's engineers, William Stanley, recognised the problem with connecting transformers in series as opposed to parallel and also realised that making the iron core of a transformer a fully enclosed loop would improve the voltage regulation of the secondary winding. Using this knowledge he built a much improved alternating current power system at Great Barrington, Massachusetts in 1886. In 1885 the Italian physicist and electrical engineer Galileo Ferraris demonstrated an induction motor and in 1887 and 1888 the Serbian-American engineer Nikola Tesla filed a range of patents related to power systems including one for a practical two-phase induction motor which Westinghouse licensed for his AC system.By 1890 the power industry had flourished and power companies had built thousands of power systems (both direct and alternating current) in the United States and Europe – these networks were effectively dedicated to providing electric lighting. During this time a fierce rivalry in the US known as the ""War of Currents"" emerged between Edison and Westinghouse over which form of transmission (direct or alternating current) was superior. In 1891, Westinghouse installed the first major power system that was designed to drive an electric motor and not just provide electric lighting. The installation powered a 100 horsepower (75 kW) synchronous motor at Telluride, Colorado with the motor being started by a Tesla induction motor. On the other side of the Atlantic, Oskar von Miller built a 20 kV 176 km three-phase transmission line from Lauffen am Neckar to Frankfurt am Main for the Electrical Engineering Exhibition in Frankfurt. In 1895, after a protracted decision-making process, the Adams No. 1 generating station at Niagara Falls began transmitting three-phase alternating current power to Buffalo at 11 kV. Following completion of the Niagara Falls project, new power systems increasingly chose alternating current as opposed to direct current for electrical transmission.Although the 1880s and 1890s were seminal decades in the field, developments in power engineering continued throughout the 20th and 21st century. In 1936 the first commercial high-voltage direct current (HVDC) line using mercury-arc valves was built between Schenectady and Mechanicville, New York. HVDC had previously been achieved by installing direct current generators in series (a system known as the Thury system) although this suffered from serious reliability issues. In 1957 Siemens demonstrated the first solid-state rectifier (solid-state rectifiers are now the standard for HVDC systems) however it was not until the early 1970s that this technology was used in commercial power systems. In 1959 Westinghouse demonstrated the first circuit breaker that used SF6 as the interrupting medium. SF6 is a far superior dielectric to air and, in recent times, its use has been extended to produce far more compact switching equipment (known as switchgear) and transformers. Many important developments also came from extending innovations in the ICT field to the power engineering field. For example, the development of computers meant load flow studies could be run more efficiently allowing for much better planning of power systems. Advances in information technology and telecommunication also allowed for much better remote control of the power system's switchgear and generators.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report