• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Difference between Bonding, Grounding and
Difference between Bonding, Grounding and

... is earthed in the basement at Basement) as neutral to power his lights. Another Person from 2nd floor has a normal setup and uses neutral for the same purpose. Neutral wire is also earthed at the ground level (as per USA practice Neutral is Grounded (earthed) at Building and as per Indian Practice i ...
RBC-12/17-D48 Series
RBC-12/17-D48 Series

Halmar Robicon 1PCI Series Manual (1 Phase)
Halmar Robicon 1PCI Series Manual (1 Phase)

1.Integrating Coupled Inductor and Switched - ISSN:2454-356X
1.Integrating Coupled Inductor and Switched - ISSN:2454-356X

... DC-DC boost converter is used for voltage step-up applications, and in this case this converter will be operated at extremely high duty ratio to achieve high stepup voltage gain. However, the voltage gain and the efficiency are limited due to the constraining effect of power switches, diodes, and th ...
Kamstrup OMNIPOWER - Smart Building Services
Kamstrup OMNIPOWER - Smart Building Services

the file
the file

... feature high power and superb quality together with superior reliability and stability, guaranteeing the highest possible audio performance. Main features of the P4500/P3200/P1600 series • Three types of input jack (balanced XLR type connectors, balanced phone jacks, and barrier strip), and five-way ...
A Simplified System for Subsynchronous Resonance Studies
A Simplified System for Subsynchronous Resonance Studies

... of no concern. There is no independent mechanical source in the system (turbine power is zero) and both masses are initially rotating at synchronous speed. The electrical subsystem has zero initial conditions. Three voltage sources are mounted on the stator side. An FFT analysis of the electromagnet ...
Harmonics Filter Design
Harmonics Filter Design

BD63872EFV
BD63872EFV

... This IC has a built in over current protection circuit as a provision against destruction when the motor outputs are shorted each other or VCC-motor output or motor output-GND is shorted. This circuit latches the motor output to OPEN condition when the regulated threshold current flows for 4μs (Typ. ...
Power supply module PS 60W 24/48/60VDC
Power supply module PS 60W 24/48/60VDC

Enquiry Form (Non-Registered Generator With Capacity less than 5
Enquiry Form (Non-Registered Generator With Capacity less than 5

... Data sheets providing full specifications for all AC circuit and related major plant. ...
3 Dynamic Power Factor Correction Using an SVC
3 Dynamic Power Factor Correction Using an SVC

... In Exercise 2, you learned that SVCs are commonly used for voltage compensation in ac transmission lines since they allow tight, fast, and effective control of the voltage at the receiver end of the line (and along the line when used in transmission substations). SVCs achieve this by supplying the e ...
TS1107, TS1110 - uri=media.digikey
TS1107, TS1110 - uri=media.digikey

... In power management and motor control applications, current-sense amplifiers are required to measure load currents accurately in the presence of both externally-generated differential and common-mode noise. An example of differential-mode noise that can appear at the inputs of a current-sense amplif ...
MAX8535EVKIT
MAX8535EVKIT

... 2) Connect the positive terminal of a 12V power supply to the PS_OUT+ banana jack. Connect the ground terminal of this power supply to the PS_OUT- banana jack. 3) Connect a voltmeter across the VBUS+ and VBUSterminals. 4) Connect an oscilloscope to TP1 on the EV kit. 5) Connect a voltmeter or an osc ...
电机控制:参考指南
电机控制:参考指南

... With high commutation performance, Snubberless™ triacs, ACS™ and ACST switches are the best choice. In addition, the latest ACS and ACST switches offer an outstanding over-voltage robustness enabling equipment to comply with the IEC6100-4-5 standard. The 500V ACS, also available in array configurati ...
Paladin Transducers 250 Series Class 0.5
Paladin Transducers 250 Series Class 0.5

... Crompton transducers and transmitters are designed for use in harsh electrical environments and feature: • High protection against overload - 20 x rated current for 1 second. • High degree of mechanical shock and vibration resistance. • Protection against high voltage. Inputs, outputs and power supp ...
ADE7755 数据手册DataSheet 下载
ADE7755 数据手册DataSheet 下载

2 A max constant current LED driver
2 A max constant current LED driver

... condition an overshoot can be present on the LED current before the system goes into regulation. ...
Enquiry Application
Enquiry Application

... Wind turbines – information required Description of the technology employed eg. WRIG, DFIG, Synchronous, Inverter Details of control methodology Transfer block model of control system and generation components with parameters suitable for transient stability study Details and impedance of fault lim ...
Protective Devices Maintenance as it Applies to the Arc/Flash
Protective Devices Maintenance as it Applies to the Arc/Flash

... ultimate goal of protective relaying is to disconnect a faulty system element as quickly as possible.  Sensitivity and selectivity are essential to ensure that the proper circuit breakers are tripped at the proper speed to: – Clear the fault – Minimize damage to equipment – Reduce the hazards to pe ...
Name of the first author et al., International Journal of Computer
Name of the first author et al., International Journal of Computer

... performance limiting blocks in such ADCs are typically inter-stage gain amplifiers and comparators. The accuracy of such comparators, which is defined by its offset, along with power consumption, speed is of keen interest in achieving overall higher performance of ADCs. In the past, pre-amplifier ba ...
Chapter 3. LOAD ELECTRICAL CHARACTERISTICS 3.1 Fixed
Chapter 3. LOAD ELECTRICAL CHARACTERISTICS 3.1 Fixed

Replacing single-phase ACIMs with three
Replacing single-phase ACIMs with three

... the process of generating the rotor magnetic field remains. A high-voltage BLDC motor requires the same inverter stage, but provides better efficiency performance compared to induction motor solutions. The capacitor in series with the auxiliary winding in a single-phase induction motor poses a relia ...
AN4363 Application note Introduction
AN4363 Application note Introduction

LM2704 Micropower Step-up DC/DC Converter
LM2704 Micropower Step-up DC/DC Converter

... The LM2704 is a micropower step-up DC/DC in a small 5-lead SOT-23 package. A current limited, fixed off-time control scheme conserves operating current resulting in high efficiency over a wide range of load conditions. The 21V switch allows for output voltages as high as 20V. The low 400ns off-time ...
< 1 ... 398 399 400 401 402 403 404 405 406 ... 1128 >

Power engineering



Power engineering, also called power systems engineering, is a subfield of energy engineering that deals with the generation, transmission, distribution and utilization of electric power and the electrical devices connected to such systems including generators, motors and transformers. Although much of the field is concerned with the problems of three-phase AC power – the standard for large-scale power transmission and distribution across the modern world – a significant fraction of the field is concerned with the conversion between AC and DC power and the development of specialized power systems such as those used in aircraft or for electric railway networks. It was a subfield of electrical engineering before the emergence of energy engineering.Electricity became a subject of scientific interest in the late 17th century with the work of William Gilbert. Over the next two centuries a number of important discoveries were made including the incandescent light bulb and the voltaic pile. Probably the greatest discovery with respect to power engineering came from Michael Faraday who in 1831 discovered that a change in magnetic flux induces an electromotive force in a loop of wire—a principle known as electromagnetic induction that helps explain how generators and transformers work.In 1881 two electricians built the world's first power station at Godalming in England. The station employed two waterwheels to produce an alternating current that was used to supply seven Siemens arc lamps at 250 volts and thirty-four incandescent lamps at 40 volts. However supply was intermittent and in 1882 Thomas Edison and his company, The Edison Electric Light Company, developed the first steam-powered electric power station on Pearl Street in New York City. The Pearl Street Station consisted of several generators and initially powered around 3,000 lamps for 59 customers. The power station used direct current and operated at a single voltage. Since the direct current power could not be easily transformed to the higher voltages necessary to minimise power loss during transmission, the possible distance between the generators and load was limited to around half-a-mile (800 m).That same year in London Lucien Gaulard and John Dixon Gibbs demonstrated the first transformer suitable for use in a real power system. The practical value of Gaulard and Gibbs' transformer was demonstrated in 1884 at Turin where the transformer was used to light up forty kilometres (25 miles) of railway from a single alternating current generator. Despite the success of the system, the pair made some fundamental mistakes. Perhaps the most serious was connecting the primaries of the transformers in series so that switching one lamp on or off would affect other lamps further down the line. Following the demonstration George Westinghouse, an American entrepreneur, imported a number of the transformers along with a Siemens generator and set his engineers to experimenting with them in the hopes of improving them for use in a commercial power system.One of Westinghouse's engineers, William Stanley, recognised the problem with connecting transformers in series as opposed to parallel and also realised that making the iron core of a transformer a fully enclosed loop would improve the voltage regulation of the secondary winding. Using this knowledge he built a much improved alternating current power system at Great Barrington, Massachusetts in 1886. In 1885 the Italian physicist and electrical engineer Galileo Ferraris demonstrated an induction motor and in 1887 and 1888 the Serbian-American engineer Nikola Tesla filed a range of patents related to power systems including one for a practical two-phase induction motor which Westinghouse licensed for his AC system.By 1890 the power industry had flourished and power companies had built thousands of power systems (both direct and alternating current) in the United States and Europe – these networks were effectively dedicated to providing electric lighting. During this time a fierce rivalry in the US known as the ""War of Currents"" emerged between Edison and Westinghouse over which form of transmission (direct or alternating current) was superior. In 1891, Westinghouse installed the first major power system that was designed to drive an electric motor and not just provide electric lighting. The installation powered a 100 horsepower (75 kW) synchronous motor at Telluride, Colorado with the motor being started by a Tesla induction motor. On the other side of the Atlantic, Oskar von Miller built a 20 kV 176 km three-phase transmission line from Lauffen am Neckar to Frankfurt am Main for the Electrical Engineering Exhibition in Frankfurt. In 1895, after a protracted decision-making process, the Adams No. 1 generating station at Niagara Falls began transmitting three-phase alternating current power to Buffalo at 11 kV. Following completion of the Niagara Falls project, new power systems increasingly chose alternating current as opposed to direct current for electrical transmission.Although the 1880s and 1890s were seminal decades in the field, developments in power engineering continued throughout the 20th and 21st century. In 1936 the first commercial high-voltage direct current (HVDC) line using mercury-arc valves was built between Schenectady and Mechanicville, New York. HVDC had previously been achieved by installing direct current generators in series (a system known as the Thury system) although this suffered from serious reliability issues. In 1957 Siemens demonstrated the first solid-state rectifier (solid-state rectifiers are now the standard for HVDC systems) however it was not until the early 1970s that this technology was used in commercial power systems. In 1959 Westinghouse demonstrated the first circuit breaker that used SF6 as the interrupting medium. SF6 is a far superior dielectric to air and, in recent times, its use has been extended to produce far more compact switching equipment (known as switchgear) and transformers. Many important developments also came from extending innovations in the ICT field to the power engineering field. For example, the development of computers meant load flow studies could be run more efficiently allowing for much better planning of power systems. Advances in information technology and telecommunication also allowed for much better remote control of the power system's switchgear and generators.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report