• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
UNIT – III Induction Motor Drives
UNIT – III Induction Motor Drives

... and the prime movers such as diesel or petrol engines, gas or steam turbines, steam engines, hydraulic motors and electric motors, for supplying mechanical energy for motion control and drives employing electric motors are known as electrical drives. 2. Specify the functions of power modulator. Powe ...
NJM3773
NJM3773

SG6742HL/HR Highly Integrated Green-Mode PWM Controller SG6742H L/H
SG6742HL/HR Highly Integrated Green-Mode PWM Controller SG6742H L/H

... reduce power consumption, SG6742HL/HR is manufactured using the BiCMOS process, which allows an operating current of 2.7mA. SG6742HL/HR integrates a frequency-hopping function internally that helps reduce EMI emission of a power supply with minimum line filters. Its built-in synchronized slope compe ...
Neo-Pod “T” Operator`s Manual, Instructions for Use
Neo-Pod “T” Operator`s Manual, Instructions for Use

... field strength in the location in which the EQUIPMENT is used exceeds the applicable RF compliance level above, the EQUIPMENT should be observed to verify normal operation. If abnormal performance is observed, additional measures may be necessary, such as reorienting or relocating the EQUIPMENT. b O ...
OWNER/INSTALLER INSTRUCTION MANUAL ET100
OWNER/INSTALLER INSTRUCTION MANUAL ET100

... TIME SWITCH. FAILURE TO COMPLY WITH INSTRUCTIONS COULD RESULT IN PERSONAL INJURY AND/OR PROPERTY DAMAGE! RETAIN FOR FUTURE REFERENCE. Description The Intermatic Electronic 24 Hour Time Switch automatically switches loads according to a preset daily schedule. This time switch is designed to directly ...
UCC2961 数据资料 dataSheet 下载
UCC2961 数据资料 dataSheet 下载

... PWM control. It is usable with a wide range of secondary control circuits and is especially well suited for systems where sophisticated handling of overload conditions is required. Secondary-side control assumes that output voltage and current measurements are interfaced directly to an output ground ...
Item Spec`s Spec`s with Sw DL 3155M09 SINGLE
Item Spec`s Spec`s with Sw DL 3155M09 SINGLE

Stray Voltage: Sources and Solutions
Stray Voltage: Sources and Solutions

... four-wire wye and solidly grounded. Voltage classes vary, but the 12470Y/7200-V system appears to be most common. There are also areas in Michigan with extensive 4800-V delta distribution. This system is not intentionally grounded but does have enough capacitive coupling in most cases to allow some ...
A motor control center
A motor control center

... energized, a direct on line (DOL) starter immediately connects the motor terminals directly to the power supply. Reduced-voltage, star-delta or soft starters connects the motor to the power supply through a voltage reduction device and increases the applied voltage gradually or in steps.[2][3][4] In ...
RF3931D RF OUT VD RF IN
RF3931D RF OUT VD RF IN

... The physical structure of the GaN HEMT results in three terminal capacitors similar to other FET technologies. These capacitances exist across all three terminals of the device. The physical manufactured characteristics of the device determine the value of the CDS (drain to source), CGS (gate to sou ...
AN58 - 5V to 3.3V Converters for Microprocessor Systems
AN58 - 5V to 3.3V Converters for Microprocessor Systems

... headroom, low dropout is essential. Low dropout regulators are available delivering currents from 125mA to 7.5A, allowing almost any microprocessor to be powered with a local 3.3V generation circuit. The first four devices (LT1020, LT1120, LT1121 and LT1129) are PNP micropower low dropout regulators ...
efficiency optimized control of high performance induction motor drive
efficiency optimized control of high performance induction motor drive

... Undoubtedly, the induction motor is a widely used electrical motor and a great energy consumer. Three-phase induction motors consume more than 60% of industrial electricity and it takes a lot of effort to improve their efficiency [1]. The vast majority of induction motor drives are used for heating, ...
Action PAK AP4380 ® DC Input,
Action PAK AP4380 ® DC Input,

... signals. The AP4380-2000 will accept input voltage spans from 10mV up to 100 volts, as well as input current spans from 1mA to 100mA. The AP4380-2001 will accept input voltages up to 200V, as well as the same input current ranges.The input zero and span potentiometers enable 50% input zero and span ...
capacitors
capacitors

Electrical Distribution System Self Assessment Survey
Electrical Distribution System Self Assessment Survey

... Loose electrical connections or worn parts generate heat and eventually lead to equipment failure or fires. These conditions are easily uncovered during infrared inspections. An infrared survey of the complete electrical system should be performed and repeated every three years. The survey should in ...
- Nottingham ePrints
- Nottingham ePrints

... and the need for a path for the zero sequence current. This path could be provided by connecting the neutral of the load to the neutral point of a zig-zag transformer [11]–[13]. However, this topology could be costly and bulky. Another option is to use a four-leg voltage source converter (VSC) on th ...
A Bidirectional LLC Resonant Converter With Automatic Forward
A Bidirectional LLC Resonant Converter With Automatic Forward

... The control scheme is very important to achieve the desired characteristics of the proposed topology. The most straightforward control scheme is turning ON and OFF the primary side switches and secondary side switches with same switching frequency [35]. The diagonal switches M1/M4 and M2/M3 in the i ...
Installation manual - Harrison Hydra-Gen
Installation manual - Harrison Hydra-Gen

... It is best to use a multimeter that can read frequency. You do not want to operate the generator above 63 HZ. Turn on the tool circuit and slowly turn the flow control adjustment screw counter-clockwise to set the frequency. Operate the generator by applying some load to the generator. Using a drill ...
Time-domain models for power system stability and unbalance
Time-domain models for power system stability and unbalance

... ATP is a time-domain power system modeling software in which all the power system components can be modeled in detail. Models are implemented with attention to component representation and parameters. The synchronous machine model includes the saturation characteristics and control interface. Transi ...
IPS Flyback application note
IPS Flyback application note

... (Domestic US) or 85 to 265 volts AC (International.) The line frequency can be 50, 60 or 400 Hertz nominal. Most designs will also operate from high-voltage DC with any polarity, like 140 volts or 120 to 400 volts. The emphasis is on low-power, low cost SMPS with one isolated low-voltage output. How ...
Design overhead distribution systems
Design overhead distribution systems

... Electric power transmission allows distant energy sources (such as hydroelectric power plants) to be connected to consumers in population centres, and may allow exploitation of low-grade fuel resources such as coal that would otherwise be too costly to transport to generating facilities. ...
Document
Document

... the logic levels of the circuit – often logic 0 is represented by a voltage close to 0 V but the allowable voltage range varies considerably – the voltage used to represent logic 1 also varies greatly. In some circuits it might be 2-4 V, while in others it might be 12-15 V – in order for one gate to ...
CubeComputer
CubeComputer

... with a mission specific expansion boards. Various interfaces (I2C, UART, and SPI) and functionality (PWM, ADC, and GPIO) have been routed to the piggyback header which can be accessed directly by the MCU. The piggyback header also has access to the full range of power supply voltages: raw battery bu ...
Chapter 25
Chapter 25

... the logic levels of the circuit – often logic 0 is represented by a voltage close to 0 V but the allowable voltage range varies considerably – the voltage used to represent logic 1 also varies greatly. In some circuits it might be 2-4 V, while in others it might be 12-15 V – in order for one gate to ...
FPF3003 IntelliMAX™ Full Functional Input Power Path
FPF3003 IntelliMAX™ Full Functional Input Power Path

... Package drawings are provided as a service to customers considering Fairchild components. Drawings may change in any manner without notice. Please note the revision and/or date on the drawing and contact a Fairchild Semiconductor representative to verify or obtain the most recent revision. Package s ...
< 1 ... 334 335 336 337 338 339 340 341 342 ... 1128 >

Power engineering



Power engineering, also called power systems engineering, is a subfield of energy engineering that deals with the generation, transmission, distribution and utilization of electric power and the electrical devices connected to such systems including generators, motors and transformers. Although much of the field is concerned with the problems of three-phase AC power – the standard for large-scale power transmission and distribution across the modern world – a significant fraction of the field is concerned with the conversion between AC and DC power and the development of specialized power systems such as those used in aircraft or for electric railway networks. It was a subfield of electrical engineering before the emergence of energy engineering.Electricity became a subject of scientific interest in the late 17th century with the work of William Gilbert. Over the next two centuries a number of important discoveries were made including the incandescent light bulb and the voltaic pile. Probably the greatest discovery with respect to power engineering came from Michael Faraday who in 1831 discovered that a change in magnetic flux induces an electromotive force in a loop of wire—a principle known as electromagnetic induction that helps explain how generators and transformers work.In 1881 two electricians built the world's first power station at Godalming in England. The station employed two waterwheels to produce an alternating current that was used to supply seven Siemens arc lamps at 250 volts and thirty-four incandescent lamps at 40 volts. However supply was intermittent and in 1882 Thomas Edison and his company, The Edison Electric Light Company, developed the first steam-powered electric power station on Pearl Street in New York City. The Pearl Street Station consisted of several generators and initially powered around 3,000 lamps for 59 customers. The power station used direct current and operated at a single voltage. Since the direct current power could not be easily transformed to the higher voltages necessary to minimise power loss during transmission, the possible distance between the generators and load was limited to around half-a-mile (800 m).That same year in London Lucien Gaulard and John Dixon Gibbs demonstrated the first transformer suitable for use in a real power system. The practical value of Gaulard and Gibbs' transformer was demonstrated in 1884 at Turin where the transformer was used to light up forty kilometres (25 miles) of railway from a single alternating current generator. Despite the success of the system, the pair made some fundamental mistakes. Perhaps the most serious was connecting the primaries of the transformers in series so that switching one lamp on or off would affect other lamps further down the line. Following the demonstration George Westinghouse, an American entrepreneur, imported a number of the transformers along with a Siemens generator and set his engineers to experimenting with them in the hopes of improving them for use in a commercial power system.One of Westinghouse's engineers, William Stanley, recognised the problem with connecting transformers in series as opposed to parallel and also realised that making the iron core of a transformer a fully enclosed loop would improve the voltage regulation of the secondary winding. Using this knowledge he built a much improved alternating current power system at Great Barrington, Massachusetts in 1886. In 1885 the Italian physicist and electrical engineer Galileo Ferraris demonstrated an induction motor and in 1887 and 1888 the Serbian-American engineer Nikola Tesla filed a range of patents related to power systems including one for a practical two-phase induction motor which Westinghouse licensed for his AC system.By 1890 the power industry had flourished and power companies had built thousands of power systems (both direct and alternating current) in the United States and Europe – these networks were effectively dedicated to providing electric lighting. During this time a fierce rivalry in the US known as the ""War of Currents"" emerged between Edison and Westinghouse over which form of transmission (direct or alternating current) was superior. In 1891, Westinghouse installed the first major power system that was designed to drive an electric motor and not just provide electric lighting. The installation powered a 100 horsepower (75 kW) synchronous motor at Telluride, Colorado with the motor being started by a Tesla induction motor. On the other side of the Atlantic, Oskar von Miller built a 20 kV 176 km three-phase transmission line from Lauffen am Neckar to Frankfurt am Main for the Electrical Engineering Exhibition in Frankfurt. In 1895, after a protracted decision-making process, the Adams No. 1 generating station at Niagara Falls began transmitting three-phase alternating current power to Buffalo at 11 kV. Following completion of the Niagara Falls project, new power systems increasingly chose alternating current as opposed to direct current for electrical transmission.Although the 1880s and 1890s were seminal decades in the field, developments in power engineering continued throughout the 20th and 21st century. In 1936 the first commercial high-voltage direct current (HVDC) line using mercury-arc valves was built between Schenectady and Mechanicville, New York. HVDC had previously been achieved by installing direct current generators in series (a system known as the Thury system) although this suffered from serious reliability issues. In 1957 Siemens demonstrated the first solid-state rectifier (solid-state rectifiers are now the standard for HVDC systems) however it was not until the early 1970s that this technology was used in commercial power systems. In 1959 Westinghouse demonstrated the first circuit breaker that used SF6 as the interrupting medium. SF6 is a far superior dielectric to air and, in recent times, its use has been extended to produce far more compact switching equipment (known as switchgear) and transformers. Many important developments also came from extending innovations in the ICT field to the power engineering field. For example, the development of computers meant load flow studies could be run more efficiently allowing for much better planning of power systems. Advances in information technology and telecommunication also allowed for much better remote control of the power system's switchgear and generators.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report