• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Sensorless Control for a Switched Reluctance Wind Generator
Sensorless Control for a Switched Reluctance Wind Generator

... where N is the number of samples in a state of commutation, ii is the ith sampled current, and iN is the last current sample. Moreover, z0 = 0, and the term [N (N 2 − 1)]−1 can be obtained from a lookup table (no more than 16 terms), avoiding a mathematical division that requires several instruction ...
Bus Edison High Speed Fuse Application
Bus Edison High Speed Fuse Application

... The non regenerative thyristor drive is widely used for variable speed control of motors. In these applications the coordination of fuses and semiconductors is often more critical than for rectifiers. The fuses are usually positioned in each arm of the bridge or the supply lines and will generally o ...
CM-5.5/7.5/10.5/15.5/20.5 Power Amplifier
CM-5.5/7.5/10.5/15.5/20.5 Power Amplifier

... The fans should be kept free of all obstructions and be accessible to cool fresh air when possible. It is important that the fans be used in a dust free environment. 2. CIRCUIT BREAKER When the circuit breaker is cut, push to reset again. In case of occuring trouble to the set by means of overload o ...
Aalborg Universitet Distributed Consensus-Based Control of Multiple DC-Microgrids Clusters Guerrero, Josep M.
Aalborg Universitet Distributed Consensus-Based Control of Multiple DC-Microgrids Clusters Guerrero, Josep M.

... other dc MGs or another dc bus, another control loop must be employed to control the power/current flow between them [10]. As power flow control can be accomplished only at the cost of having the voltage deviation inside the system, the centralized secondary control action could disable this feature ...
a-isometer® ir420 - Bender Benelux BV
a-isometer® ir420 - Bender Benelux BV

Seminar Report
Seminar Report

... flexibility and efficiency to the customers. However, their proliferation during the last decade is creating a growing concern andgenerates more and more problems: not only these electronic loads pollutethe AC distribution system with harmonic currents, but they also appear to be verysensitive to th ...
Interconnect Protection of IPP Generators Using Digital Technology
Interconnect Protection of IPP Generators Using Digital Technology

Simple novice transmitter for the 3.5MHz amateur band
Simple novice transmitter for the 3.5MHz amateur band

chapter- 9 hydro generator, characteristics and performance
chapter- 9 hydro generator, characteristics and performance

... 9.3.1.2 Number of starts and application of load: Anticipated no. of starts and maximum MVA, power, and reactive power loading rate of change are requirements for the manufacturer to take into account in the machine design. The method of starting must be identified in the case of peaking stations. ...
NOTICE TO INSTALLER:  Instructions must remain with installation. SECTION: 6.10.100
NOTICE TO INSTALLER: Instructions must remain with installation. SECTION: 6.10.100

Leakage Current Modeling in PD SOI Circuits
Leakage Current Modeling in PD SOI Circuits

... were tiss is the Isub settling time. The scatter plot data comparing the data for this approximation is shown in Fig. 10. Each point in the plot represents Isub magnitude at the given time obtained from spice simulation with an input pulse train and the corresponding Isub magnitude obtained with equ ...
dc motor control
dc motor control

... In this project we use one IC which is LM324 which include four operational amplifier two are used for triangular wave one for comparator.Op-amp N1, N2 &N3 are work as triangular wave generator, square wave generator and comparator respectively. Op-amp N2 generates square wave and it fed to invertin ...
AP6502A Description Pin Assignments
AP6502A Description Pin Assignments

... falling edge of the oscillator clock resets the Flip-Flop. The output of the error amplifier increases when feedback voltage (VFB) is lower than the reference voltage of 0.925V. This also increases the inductor current as it is proportional to the EA voltage. If in one cycle the current in the power ...
MOSFETs Basics
MOSFETs Basics

... N-channel enhancement type MOSFETS are the most popular for use in power switching circuits and applications. The drive voltage or voltage applied between gate and source to switch the MOSFET ON must exceed a threshold value VT 4V although values of 10 - 12V are actually needed to ensure the MOSFET ...
AN162 : Power On Conditions for the X9258
AN162 : Power On Conditions for the X9258

... reverse direction) and contain no noise greater than 100mV. See Figure 3. 3. Noise or voltage direction changes are especially significant when VCC is in the range of 1.9 to 2.4V. See Figure 4. 4. If the voltage on VCC reaches 1.9 to 2.4V, but has not reached 2.7V, and then falls to less than 1V, it ...
specifications
specifications

... power switch. When you need to degauss while using the monitor select DEGAUSS in the SPECIAL on the OSD menu. 3. SMPS(Switching Mode Power Supply). This circuit works with power of 90~132Vac/196~264 Vac (50/60Hz). The operation procedure is as follows: 1) AC input voltage is rectified and smoothed b ...
6.0 Electrical Installations - Department of Electrical Engineering
6.0 Electrical Installations - Department of Electrical Engineering

... An electrical installation is a combination of electrical equipment installed to fulfill a specific purpose and having coordinated characteristics. In dealing with the electrical installation, it is necessary to ensure the safety of personnel as well as the protection of equipment from electrical fa ...
mosfet_s-f.pdf
mosfet_s-f.pdf

... You have to have the source of the MOSFET be able to sit at -36V, and swing to several volts positive to get into positive grid voltage on the output tubes. That means that they have to be able to swing the same amount of voltage negative on the other half cycle of signal to be able to turn the offs ...
FPGA Based Speed Control of Three
FPGA Based Speed Control of Three

... bidirectional switches as shown in Fig.1. Three switches are connected in series with stator terminals of the motor and another three are used to provide freewheeling path across stator windings. In this study a saw-tooth PWM strategy has been used to control the speed of three-phase induction motor ...
Film Capacitors - AC Capacitors - Application Note
Film Capacitors - AC Capacitors - Application Note

... 80 μH reduces the first peak current to below 250 A (See Figure 2) with a duration of 110 µs. Tests at the STMicroelectronics laboratories have shown best results when using an LCap from EPCOS, an integrated capacitor and inductor device combining the phase shift capacitor with the current limitatio ...
Lecture6 –Crypto Implementation on Embedded Platforms
Lecture6 –Crypto Implementation on Embedded Platforms

... DPA (cont’d) • The DPA waveform with the highest peak will validate the hypothesis ...
Aalborg Universitet Optimized Integrated Harmonic Filter Inductor for Dual-Converter Fed Open-End
Aalborg Universitet Optimized Integrated Harmonic Filter Inductor for Dual-Converter Fed Open-End

... I. I NTRODUCTION Many high power converter systems are often connected to the medium voltage network and a step-up transformer is used to match the voltage levels of the converter with the medium voltage grid. In some applications, the transformer is also required for providing galvanic isolation. I ...
DATASHEET SEARCH SITE | WWW.ALLDATASHEET.COM
DATASHEET SEARCH SITE | WWW.ALLDATASHEET.COM

3rd Harmonic Filters
3rd Harmonic Filters

... MTE’s 3rd HARMONIC FILTERS are designed to reduce each of the individual harmonics from 3rd through 9th. Typical reduction of the 3rd harmonic is often as much as 80% - 90%. Additionally, triplen harmonics, which sum together in the neutral conductor, are minimized with this filter. REDUCE SYSTEM RE ...
FRDM-KE02Z User’s Manual  Rev. 0
FRDM-KE02Z User’s Manual Rev. 0

... The Freescale KE02Z freedom board (FRDM-KE02Z) is a simple, yet sophisticated design featuring a Kinetis E Series microcontroller KE02Z64VQH2, the industry’s first microcontroller built on the ARM® Cortex™-M0+ core with 0.18um process. The Kinetis E series is the most scalable portfolio of low-power ...
< 1 ... 325 326 327 328 329 330 331 332 333 ... 1128 >

Power engineering



Power engineering, also called power systems engineering, is a subfield of energy engineering that deals with the generation, transmission, distribution and utilization of electric power and the electrical devices connected to such systems including generators, motors and transformers. Although much of the field is concerned with the problems of three-phase AC power – the standard for large-scale power transmission and distribution across the modern world – a significant fraction of the field is concerned with the conversion between AC and DC power and the development of specialized power systems such as those used in aircraft or for electric railway networks. It was a subfield of electrical engineering before the emergence of energy engineering.Electricity became a subject of scientific interest in the late 17th century with the work of William Gilbert. Over the next two centuries a number of important discoveries were made including the incandescent light bulb and the voltaic pile. Probably the greatest discovery with respect to power engineering came from Michael Faraday who in 1831 discovered that a change in magnetic flux induces an electromotive force in a loop of wire—a principle known as electromagnetic induction that helps explain how generators and transformers work.In 1881 two electricians built the world's first power station at Godalming in England. The station employed two waterwheels to produce an alternating current that was used to supply seven Siemens arc lamps at 250 volts and thirty-four incandescent lamps at 40 volts. However supply was intermittent and in 1882 Thomas Edison and his company, The Edison Electric Light Company, developed the first steam-powered electric power station on Pearl Street in New York City. The Pearl Street Station consisted of several generators and initially powered around 3,000 lamps for 59 customers. The power station used direct current and operated at a single voltage. Since the direct current power could not be easily transformed to the higher voltages necessary to minimise power loss during transmission, the possible distance between the generators and load was limited to around half-a-mile (800 m).That same year in London Lucien Gaulard and John Dixon Gibbs demonstrated the first transformer suitable for use in a real power system. The practical value of Gaulard and Gibbs' transformer was demonstrated in 1884 at Turin where the transformer was used to light up forty kilometres (25 miles) of railway from a single alternating current generator. Despite the success of the system, the pair made some fundamental mistakes. Perhaps the most serious was connecting the primaries of the transformers in series so that switching one lamp on or off would affect other lamps further down the line. Following the demonstration George Westinghouse, an American entrepreneur, imported a number of the transformers along with a Siemens generator and set his engineers to experimenting with them in the hopes of improving them for use in a commercial power system.One of Westinghouse's engineers, William Stanley, recognised the problem with connecting transformers in series as opposed to parallel and also realised that making the iron core of a transformer a fully enclosed loop would improve the voltage regulation of the secondary winding. Using this knowledge he built a much improved alternating current power system at Great Barrington, Massachusetts in 1886. In 1885 the Italian physicist and electrical engineer Galileo Ferraris demonstrated an induction motor and in 1887 and 1888 the Serbian-American engineer Nikola Tesla filed a range of patents related to power systems including one for a practical two-phase induction motor which Westinghouse licensed for his AC system.By 1890 the power industry had flourished and power companies had built thousands of power systems (both direct and alternating current) in the United States and Europe – these networks were effectively dedicated to providing electric lighting. During this time a fierce rivalry in the US known as the ""War of Currents"" emerged between Edison and Westinghouse over which form of transmission (direct or alternating current) was superior. In 1891, Westinghouse installed the first major power system that was designed to drive an electric motor and not just provide electric lighting. The installation powered a 100 horsepower (75 kW) synchronous motor at Telluride, Colorado with the motor being started by a Tesla induction motor. On the other side of the Atlantic, Oskar von Miller built a 20 kV 176 km three-phase transmission line from Lauffen am Neckar to Frankfurt am Main for the Electrical Engineering Exhibition in Frankfurt. In 1895, after a protracted decision-making process, the Adams No. 1 generating station at Niagara Falls began transmitting three-phase alternating current power to Buffalo at 11 kV. Following completion of the Niagara Falls project, new power systems increasingly chose alternating current as opposed to direct current for electrical transmission.Although the 1880s and 1890s were seminal decades in the field, developments in power engineering continued throughout the 20th and 21st century. In 1936 the first commercial high-voltage direct current (HVDC) line using mercury-arc valves was built between Schenectady and Mechanicville, New York. HVDC had previously been achieved by installing direct current generators in series (a system known as the Thury system) although this suffered from serious reliability issues. In 1957 Siemens demonstrated the first solid-state rectifier (solid-state rectifiers are now the standard for HVDC systems) however it was not until the early 1970s that this technology was used in commercial power systems. In 1959 Westinghouse demonstrated the first circuit breaker that used SF6 as the interrupting medium. SF6 is a far superior dielectric to air and, in recent times, its use has been extended to produce far more compact switching equipment (known as switchgear) and transformers. Many important developments also came from extending innovations in the ICT field to the power engineering field. For example, the development of computers meant load flow studies could be run more efficiently allowing for much better planning of power systems. Advances in information technology and telecommunication also allowed for much better remote control of the power system's switchgear and generators.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report