• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Voltage conversion ratios for switched-capacitor
Voltage conversion ratios for switched-capacitor

... Y. P. B. YEUNG, K. W. E. CHENG and D. Sutanto Power Electronics Research Centre Department of Electrical Engineering The Hong Kong Polytechnic University Hung Hom, Hong Kong classical ...
Harmonic Presentation
Harmonic Presentation

Galvanometer Mirror Systems (Page 1 of 3)
Galvanometer Mirror Systems (Page 1 of 3)

... an optical mirror mounted on the shaft and a detector that provides positional feedback to the control board. The moving magnet design for the GVS series of galvanometer motors was chosen over a stationary magnet and rotating coil design in order to provide the fastest response times and the highest ...
SKY77761-11 数据资料DataSheet下载
SKY77761-11 数据资料DataSheet下载

AAT4672 数据资料DataSheet下载
AAT4672 数据资料DataSheet下载

... Information in this document is provided in connection with Skyworks Solutions, Inc. (“Skyworks”) products or services. These materials, including the information contained herein, are provided by Skyworks as a service to its customers and may be used for informational purposes only by the customer. ...
NA Y.3 Connections to mains
NA Y.3 Connections to mains

LM340 Series Three Terminal Positive Regulators
LM340 Series Three Terminal Positive Regulators

... using R1, R2, and D1. Assuming the base-to-emitter voltage of Q1 and the voltage drop across D1 are equal, the voltage drops across R1 and R2 are equal. The currents through R1 and R2 will then be inversely proportional to their resistances. For the example shown on Figure 6 , resistor R1 will have ...
Evaluates:  MAX15038/MAX15039 MAX15038 Evaluation Kit General Description Features
Evaluates: MAX15038/MAX15039 MAX15038 Evaluation Kit General Description Features

... 2MHz step-down regulator with integrated switches in a 24-pin TQFN surface-mount package with an exposed pad. Applications include enterprise-server, telecommunication, computing, and networking power supplies. The EV kit generates selectable output voltages from 0.6V to 2.5V at load currents up to ...
1 - North American SynchroPhasor Initiative
1 - North American SynchroPhasor Initiative

... In a generation station, it is desirable to measure all the line currents (including the step-up transformer) and both the high-side and low-side voltages. In situations where it is not practical to locate a PMU directly at a generator substation, PMUs can be placed on neighboring buses, with curren ...
+ + + + + + + + Space charge region
+ + + + + + + + Space charge region

... with an N-type Semiconductor a PN junction is formed. And it is also known as a Semiconductor Diode. Semiconductor diodes are widely used in Rectifiers which converts input AC signal into DC output signal. ...
MP4459 – 1.5A, 4MHz, 36V STEP
MP4459 – 1.5A, 4MHz, 36V STEP

Cinénova Grande - earthquakedenmark.dk
Cinénova Grande - earthquakedenmark.dk

... block, used in both the 5-channel and 7-channel Cinénova grande amplifiers. The "Alpha One" blocks are individually removable using the Earthquake patented "EZXS" system, without the need to dismantle the rest of the amplifier. Channel separation exceeds the norms of 90 decibels and stretches it to ...
Performance Analysis of Four Leg Voltage Source Inverter Fed
Performance Analysis of Four Leg Voltage Source Inverter Fed

... The 4-leg H-bridge inverter comprise of two single phase full bridge inverters. Four legs that generate two output voltages separately which ranges from – Vdc to +Vdc, where Vdc is the input dc voltage to the inverter. The load i.e, TwPIM is connected in between two separate bridges as shown in fig. ...
Indoor Light Energy Harvesting Reference Design for Bluetooth
Indoor Light Energy Harvesting Reference Design for Bluetooth

... Once started, the boost charger can effectively extract power from low voltage output harvesters such as TEGs or single or dual cell solar panels. The boost charger can be started with VIN as low as 330 mV, and once started, can continue to harvest energy down to VIN = 100 mV. The bq25505 implements ...
MINIGORILLA USER GUIDE
MINIGORILLA USER GUIDE

... the battery from over-charging or excessive discharging. In low light conditions, this technology improves efficiency by up to 60%. • minigorilla will automatically detect when the solargorilla solar charger is connected and the symbol ‘ ’ will be displayed. This will disable ...
measurement methods and interpretation algorithms for the
measurement methods and interpretation algorithms for the

... состоянием изоляции около 140 турбо и гидрогенераторов в течение 25 лет. Предложена программа измерений, которая будет применена и которая позволит оценить по данным измерений в режиме off-line и on-line остаточный ресурс изоляции. Ключевые слова: методы измерения электрической изоляции, электрическ ...
SP385A
SP385A

Nonlinear Modeling of DC Constant Power Loads with
Nonlinear Modeling of DC Constant Power Loads with

... Distributed power systems connect spatially separate electrical power sources to electrical loads. Most designs use more than one voltage level, usually lower voltages at the source and load ends and higher voltages for long distance interconnects to reduce I 2 R losses in cabling. Before power elec ...
AP6507  500 kHz 18V 3A SYNCHRONOUS DC/DC BUCK CONVERTER Description
AP6507 500 kHz 18V 3A SYNCHRONOUS DC/DC BUCK CONVERTER Description

... For one whole cycle, if the sum of the current sensing amplifier output and the slope compensation signal does not exceed the EA output, then the falling edge of the oscillator clock resets the flip-flop. The output of the EA increases when feedback voltage (VFB) is lower than the reference voltage ...
FDMS3602S  PowerTrench Power Stage
FDMS3602S PowerTrench Power Stage

... to the part between D1 and S2. Input capacitors should be connected in parallel close to the part. Multiple input caps can be connected depending upon the application. 2. The PHASE copper trace serves two purposes; In addition to being the current path from the Power Stage package to the output indu ...
PHYS-204: College Physics II
PHYS-204: College Physics II

thermal crisis: challenges and potential solutions
thermal crisis: challenges and potential solutions

... temperature also affects power consumption. High-chip power consumption increases cooling power consumption, e.g., from fans. Leakage power consumption, a major problem in nanometer scale devices, also increases with chip temperature. Therefore, chip power consumption and temperature form a positive ...
Document
Document

... Two traces placed side-by-side as in Figure 3(b) form a kind of transformer. The magnetic field produced by one couples to the other. The coupled signals travel down the victim line both toward the load and backwards toward the source. In practice, it is the “backward crosstalk” that generally prove ...
Lionel E-Unit 00-0103-00 Theory of Operation
Lionel E-Unit 00-0103-00 Theory of Operation

... Flip/Flop. The Flip/Flops are powered by VCC (which remains constant even during AC input power dropouts). A Power-On Reset Circuit (C4 and R12) is a simple differentiator that will generate a short pulse (RESET) which is sent to the Reset Inputs (R) on each Flip/Flop. The pulse will only be generat ...
FDMS3615S  PowerTrench Power Stage
FDMS3615S PowerTrench Power Stage

... to the part between D1 and S2. Input capacitors should be connected in parallel close to the part. Multiple input caps can be connected depending upon the application. 2. The PHASE copper trace serves two purposes; In addition to being the current path from the Power Stage package to the output indu ...
< 1 ... 315 316 317 318 319 320 321 322 323 ... 1128 >

Power engineering



Power engineering, also called power systems engineering, is a subfield of energy engineering that deals with the generation, transmission, distribution and utilization of electric power and the electrical devices connected to such systems including generators, motors and transformers. Although much of the field is concerned with the problems of three-phase AC power – the standard for large-scale power transmission and distribution across the modern world – a significant fraction of the field is concerned with the conversion between AC and DC power and the development of specialized power systems such as those used in aircraft or for electric railway networks. It was a subfield of electrical engineering before the emergence of energy engineering.Electricity became a subject of scientific interest in the late 17th century with the work of William Gilbert. Over the next two centuries a number of important discoveries were made including the incandescent light bulb and the voltaic pile. Probably the greatest discovery with respect to power engineering came from Michael Faraday who in 1831 discovered that a change in magnetic flux induces an electromotive force in a loop of wire—a principle known as electromagnetic induction that helps explain how generators and transformers work.In 1881 two electricians built the world's first power station at Godalming in England. The station employed two waterwheels to produce an alternating current that was used to supply seven Siemens arc lamps at 250 volts and thirty-four incandescent lamps at 40 volts. However supply was intermittent and in 1882 Thomas Edison and his company, The Edison Electric Light Company, developed the first steam-powered electric power station on Pearl Street in New York City. The Pearl Street Station consisted of several generators and initially powered around 3,000 lamps for 59 customers. The power station used direct current and operated at a single voltage. Since the direct current power could not be easily transformed to the higher voltages necessary to minimise power loss during transmission, the possible distance between the generators and load was limited to around half-a-mile (800 m).That same year in London Lucien Gaulard and John Dixon Gibbs demonstrated the first transformer suitable for use in a real power system. The practical value of Gaulard and Gibbs' transformer was demonstrated in 1884 at Turin where the transformer was used to light up forty kilometres (25 miles) of railway from a single alternating current generator. Despite the success of the system, the pair made some fundamental mistakes. Perhaps the most serious was connecting the primaries of the transformers in series so that switching one lamp on or off would affect other lamps further down the line. Following the demonstration George Westinghouse, an American entrepreneur, imported a number of the transformers along with a Siemens generator and set his engineers to experimenting with them in the hopes of improving them for use in a commercial power system.One of Westinghouse's engineers, William Stanley, recognised the problem with connecting transformers in series as opposed to parallel and also realised that making the iron core of a transformer a fully enclosed loop would improve the voltage regulation of the secondary winding. Using this knowledge he built a much improved alternating current power system at Great Barrington, Massachusetts in 1886. In 1885 the Italian physicist and electrical engineer Galileo Ferraris demonstrated an induction motor and in 1887 and 1888 the Serbian-American engineer Nikola Tesla filed a range of patents related to power systems including one for a practical two-phase induction motor which Westinghouse licensed for his AC system.By 1890 the power industry had flourished and power companies had built thousands of power systems (both direct and alternating current) in the United States and Europe – these networks were effectively dedicated to providing electric lighting. During this time a fierce rivalry in the US known as the ""War of Currents"" emerged between Edison and Westinghouse over which form of transmission (direct or alternating current) was superior. In 1891, Westinghouse installed the first major power system that was designed to drive an electric motor and not just provide electric lighting. The installation powered a 100 horsepower (75 kW) synchronous motor at Telluride, Colorado with the motor being started by a Tesla induction motor. On the other side of the Atlantic, Oskar von Miller built a 20 kV 176 km three-phase transmission line from Lauffen am Neckar to Frankfurt am Main for the Electrical Engineering Exhibition in Frankfurt. In 1895, after a protracted decision-making process, the Adams No. 1 generating station at Niagara Falls began transmitting three-phase alternating current power to Buffalo at 11 kV. Following completion of the Niagara Falls project, new power systems increasingly chose alternating current as opposed to direct current for electrical transmission.Although the 1880s and 1890s were seminal decades in the field, developments in power engineering continued throughout the 20th and 21st century. In 1936 the first commercial high-voltage direct current (HVDC) line using mercury-arc valves was built between Schenectady and Mechanicville, New York. HVDC had previously been achieved by installing direct current generators in series (a system known as the Thury system) although this suffered from serious reliability issues. In 1957 Siemens demonstrated the first solid-state rectifier (solid-state rectifiers are now the standard for HVDC systems) however it was not until the early 1970s that this technology was used in commercial power systems. In 1959 Westinghouse demonstrated the first circuit breaker that used SF6 as the interrupting medium. SF6 is a far superior dielectric to air and, in recent times, its use has been extended to produce far more compact switching equipment (known as switchgear) and transformers. Many important developments also came from extending innovations in the ICT field to the power engineering field. For example, the development of computers meant load flow studies could be run more efficiently allowing for much better planning of power systems. Advances in information technology and telecommunication also allowed for much better remote control of the power system's switchgear and generators.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report