MAX9820 - Maxim Integrated
... charges the coupling capacitor to its bias voltage, typically half the supply. Likewise, on shutdown, the capacitor is discharged. This results in a DC shift across the capacitor, which appears as an audible transient at the speaker. Since DirectDrive biases the outputs at ground, this problem does ...
... charges the coupling capacitor to its bias voltage, typically half the supply. Likewise, on shutdown, the capacitor is discharged. This results in a DC shift across the capacitor, which appears as an audible transient at the speaker. Since DirectDrive biases the outputs at ground, this problem does ...
— mWSaver™ PWM Controller FAN6757 FAN 6
... High-Voltage Startup. This pin is connected to the line input or bulk capacitor, via 200 kΩ resistors, to achieve brownout and high/low line compensation. If the voltage of the HV pin is lower than the brownout voltage (AC line peak voltage less than 100 V) and lasts for 65 ms, PWM output turns off. ...
... High-Voltage Startup. This pin is connected to the line input or bulk capacitor, via 200 kΩ resistors, to achieve brownout and high/low line compensation. If the voltage of the HV pin is lower than the brownout voltage (AC line peak voltage less than 100 V) and lasts for 65 ms, PWM output turns off. ...
Stakeholder Comparison Comment Rationale Matrix 2011-09-28 AESO AUTHORITATIVE DOCUMENT PROCESS
... fault conditions and evaluate the above relay’s loadability at 0.85 per unit voltage and a power factor angle of 30 degrees. ...
... fault conditions and evaluate the above relay’s loadability at 0.85 per unit voltage and a power factor angle of 30 degrees. ...
BDTIC
... In order to avoid cross conduction between the High Side MOSFET and the Low Side MOSFET an anti-shootthrough control is implemented with the adaptive scheme. The adaptive scheme is implemented in order to use a variety of different power MOSFETs for different kind of conversion. Nevertheless the dea ...
... In order to avoid cross conduction between the High Side MOSFET and the Low Side MOSFET an anti-shootthrough control is implemented with the adaptive scheme. The adaptive scheme is implemented in order to use a variety of different power MOSFETs for different kind of conversion. Nevertheless the dea ...
Three-Phase Distribution Board
... It is supplied with three neutral bars. It is of the utmost importance that the various circuit neutrals are not mixed up in any way. A wrong neutral connection will result in the tripping of one or other RCD. It is possible to supply the single-phase loads through a three-phase RCD. This would simp ...
... It is supplied with three neutral bars. It is of the utmost importance that the various circuit neutrals are not mixed up in any way. A wrong neutral connection will result in the tripping of one or other RCD. It is possible to supply the single-phase loads through a three-phase RCD. This would simp ...
Design of a Modified Cockcroft Walton Generator
... working principle of CWVM requires consideration of transient behavior and analysis under various load current. Zi-Feng He, Jin-Ling Zhang, Yong-Hao Liu, Yu-Tian Zhang and Yin Zhang (2011) [5] found that the voltage drop with in the ciruit increases linearly as the load current increases. The voltag ...
... working principle of CWVM requires consideration of transient behavior and analysis under various load current. Zi-Feng He, Jin-Ling Zhang, Yong-Hao Liu, Yu-Tian Zhang and Yin Zhang (2011) [5] found that the voltage drop with in the ciruit increases linearly as the load current increases. The voltag ...
Evaluates: MAX8550/MAX8550A/MAX8551 MAX8550 Evaluation Kit General Description Features
... MAX8550 Evaluation Kit falling transitions and may interfere with circuit performance and generate EMI. To dampen this ringing, an optional series RC snubber circuit is added across the low-side switch. Below is a simple procedure for selecting the value of the series RC for the snubber circuit: 1) ...
... MAX8550 Evaluation Kit falling transitions and may interfere with circuit performance and generate EMI. To dampen this ringing, an optional series RC snubber circuit is added across the low-side switch. Below is a simple procedure for selecting the value of the series RC for the snubber circuit: 1) ...
ADP1710,11
... Internally, the ADP1710/ADP1711 each consist of a reference, an error amplifier, a feedback voltage divider, and a PMOS pass transistor. Output current is delivered via the PMOS pass device, which is controlled by the error amplifier. The error amplifier compares the reference voltage with the feedb ...
... Internally, the ADP1710/ADP1711 each consist of a reference, an error amplifier, a feedback voltage divider, and a PMOS pass transistor. Output current is delivered via the PMOS pass device, which is controlled by the error amplifier. The error amplifier compares the reference voltage with the feedb ...
DATA SHEET CGY2014ATW GSM/DCS/PCS power amplifier Preliminary specification
... fine solder particles, flux and binding agent) to be applied to the printed-circuit board by screen printing, stencilling or ...
... fine solder particles, flux and binding agent) to be applied to the printed-circuit board by screen printing, stencilling or ...
AL5801 Description Features Pin Assignments Applications Typical
... written approval of the Chief Executive Officer of Diodes Incorporated. As used herein: A. Life support devices or systems are devices or systems which: 1. are intended to implant into the body, or 2. support or sustain life and whose failure to perform when properly used in accordance with instruct ...
... written approval of the Chief Executive Officer of Diodes Incorporated. As used herein: A. Life support devices or systems are devices or systems which: 1. are intended to implant into the body, or 2. support or sustain life and whose failure to perform when properly used in accordance with instruct ...
MP4460 - Monolithic Power System
... regulator with an integrated high-side high voltage power MOSFET. It provides a single highly efficient solution with current mode control for fast loop response and easy compensation. It features a wide input voltage range, internal soft-start control and precision current limiting. Its very low op ...
... regulator with an integrated high-side high voltage power MOSFET. It provides a single highly efficient solution with current mode control for fast loop response and easy compensation. It features a wide input voltage range, internal soft-start control and precision current limiting. Its very low op ...
BDTIC
... Due to technical requirements, components may contain dangerous substances. For information on the types in question, please contact the nearest Infineon Technologies Office. Infineon Technologies components may be used in life-support devices or systems only with the express written approval of Inf ...
... Due to technical requirements, components may contain dangerous substances. For information on the types in question, please contact the nearest Infineon Technologies Office. Infineon Technologies components may be used in life-support devices or systems only with the express written approval of Inf ...
style guidelines to assist authors preparing papers using ms word
... An alternative approach is to use an inverter bridge that is capable of performing three-level control of the output waveform. While the variable speed drive itself may, initially appear to be more expensive, the need for output chokes, filters or motor terminating devices is eliminated and motor fa ...
... An alternative approach is to use an inverter bridge that is capable of performing three-level control of the output waveform. While the variable speed drive itself may, initially appear to be more expensive, the need for output chokes, filters or motor terminating devices is eliminated and motor fa ...
Winding pitch
... when two such generators are connected in parallel, they will produce a line-to-neutral voltage that at any given instant reflects the differences between the two generator voltages. This line-to-neutral voltage will primarily be at the 3rd harmonic of the system frequency, for example 150 Hz in a 5 ...
... when two such generators are connected in parallel, they will produce a line-to-neutral voltage that at any given instant reflects the differences between the two generator voltages. This line-to-neutral voltage will primarily be at the 3rd harmonic of the system frequency, for example 150 Hz in a 5 ...
Electronically Commutated Motors
... CAUTION: Sheet metal parts, screws, clips and similar items inherently have sharp edges, and it is necessary that the installer and service personnel exercise caution. CAUTION: Surface temperatures of motor may reach temperatures which can cause discomfort or injury to personnel accidentally coming ...
... CAUTION: Sheet metal parts, screws, clips and similar items inherently have sharp edges, and it is necessary that the installer and service personnel exercise caution. CAUTION: Surface temperatures of motor may reach temperatures which can cause discomfort or injury to personnel accidentally coming ...
How to Install a PowerNet™ IPBridge Copyright © 2013, ISONAS Security Systems
... This guide discusses each process separately. Understanding all of these processes makes a project much simpler and guarantees success. ...
... This guide discusses each process separately. Understanding all of these processes makes a project much simpler and guarantees success. ...
Experiment FT1
... Capacitor, also known as an electrical condenser, is a device that can store electric charge or energy. It can also be used in various types of circuit functions involving: i) Oscillator (alternate charging and discharging of the capacitor); ii) Blocking the flow of direct current; iii) Filter (vary ...
... Capacitor, also known as an electrical condenser, is a device that can store electric charge or energy. It can also be used in various types of circuit functions involving: i) Oscillator (alternate charging and discharging of the capacitor); ii) Blocking the flow of direct current; iii) Filter (vary ...
vcodesign paper
... However, these oscillators, not having inductors, usually have less spectral purity than their LC counterparts. Among the three topologies, LC based oscillators are most prominent ones due to their relatively low phase noise. Resonator-based VCOs work with the principle of adding negative resistance ...
... However, these oscillators, not having inductors, usually have less spectral purity than their LC counterparts. Among the three topologies, LC based oscillators are most prominent ones due to their relatively low phase noise. Resonator-based VCOs work with the principle of adding negative resistance ...
Power engineering
Power engineering, also called power systems engineering, is a subfield of energy engineering that deals with the generation, transmission, distribution and utilization of electric power and the electrical devices connected to such systems including generators, motors and transformers. Although much of the field is concerned with the problems of three-phase AC power – the standard for large-scale power transmission and distribution across the modern world – a significant fraction of the field is concerned with the conversion between AC and DC power and the development of specialized power systems such as those used in aircraft or for electric railway networks. It was a subfield of electrical engineering before the emergence of energy engineering.Electricity became a subject of scientific interest in the late 17th century with the work of William Gilbert. Over the next two centuries a number of important discoveries were made including the incandescent light bulb and the voltaic pile. Probably the greatest discovery with respect to power engineering came from Michael Faraday who in 1831 discovered that a change in magnetic flux induces an electromotive force in a loop of wire—a principle known as electromagnetic induction that helps explain how generators and transformers work.In 1881 two electricians built the world's first power station at Godalming in England. The station employed two waterwheels to produce an alternating current that was used to supply seven Siemens arc lamps at 250 volts and thirty-four incandescent lamps at 40 volts. However supply was intermittent and in 1882 Thomas Edison and his company, The Edison Electric Light Company, developed the first steam-powered electric power station on Pearl Street in New York City. The Pearl Street Station consisted of several generators and initially powered around 3,000 lamps for 59 customers. The power station used direct current and operated at a single voltage. Since the direct current power could not be easily transformed to the higher voltages necessary to minimise power loss during transmission, the possible distance between the generators and load was limited to around half-a-mile (800 m).That same year in London Lucien Gaulard and John Dixon Gibbs demonstrated the first transformer suitable for use in a real power system. The practical value of Gaulard and Gibbs' transformer was demonstrated in 1884 at Turin where the transformer was used to light up forty kilometres (25 miles) of railway from a single alternating current generator. Despite the success of the system, the pair made some fundamental mistakes. Perhaps the most serious was connecting the primaries of the transformers in series so that switching one lamp on or off would affect other lamps further down the line. Following the demonstration George Westinghouse, an American entrepreneur, imported a number of the transformers along with a Siemens generator and set his engineers to experimenting with them in the hopes of improving them for use in a commercial power system.One of Westinghouse's engineers, William Stanley, recognised the problem with connecting transformers in series as opposed to parallel and also realised that making the iron core of a transformer a fully enclosed loop would improve the voltage regulation of the secondary winding. Using this knowledge he built a much improved alternating current power system at Great Barrington, Massachusetts in 1886. In 1885 the Italian physicist and electrical engineer Galileo Ferraris demonstrated an induction motor and in 1887 and 1888 the Serbian-American engineer Nikola Tesla filed a range of patents related to power systems including one for a practical two-phase induction motor which Westinghouse licensed for his AC system.By 1890 the power industry had flourished and power companies had built thousands of power systems (both direct and alternating current) in the United States and Europe – these networks were effectively dedicated to providing electric lighting. During this time a fierce rivalry in the US known as the ""War of Currents"" emerged between Edison and Westinghouse over which form of transmission (direct or alternating current) was superior. In 1891, Westinghouse installed the first major power system that was designed to drive an electric motor and not just provide electric lighting. The installation powered a 100 horsepower (75 kW) synchronous motor at Telluride, Colorado with the motor being started by a Tesla induction motor. On the other side of the Atlantic, Oskar von Miller built a 20 kV 176 km three-phase transmission line from Lauffen am Neckar to Frankfurt am Main for the Electrical Engineering Exhibition in Frankfurt. In 1895, after a protracted decision-making process, the Adams No. 1 generating station at Niagara Falls began transmitting three-phase alternating current power to Buffalo at 11 kV. Following completion of the Niagara Falls project, new power systems increasingly chose alternating current as opposed to direct current for electrical transmission.Although the 1880s and 1890s were seminal decades in the field, developments in power engineering continued throughout the 20th and 21st century. In 1936 the first commercial high-voltage direct current (HVDC) line using mercury-arc valves was built between Schenectady and Mechanicville, New York. HVDC had previously been achieved by installing direct current generators in series (a system known as the Thury system) although this suffered from serious reliability issues. In 1957 Siemens demonstrated the first solid-state rectifier (solid-state rectifiers are now the standard for HVDC systems) however it was not until the early 1970s that this technology was used in commercial power systems. In 1959 Westinghouse demonstrated the first circuit breaker that used SF6 as the interrupting medium. SF6 is a far superior dielectric to air and, in recent times, its use has been extended to produce far more compact switching equipment (known as switchgear) and transformers. Many important developments also came from extending innovations in the ICT field to the power engineering field. For example, the development of computers meant load flow studies could be run more efficiently allowing for much better planning of power systems. Advances in information technology and telecommunication also allowed for much better remote control of the power system's switchgear and generators.