• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
ECODRIVE DKC03.1 Drive Controller
ECODRIVE DKC03.1 Drive Controller

... the product as well as all warnings and precautionary measures in this documentation. Furthermore, personnel should be trained, instructed or authorised to switch electrical circuits on and off and to ground and mark them in accordance with the requirements of safety engineering. Personnel should po ...
Telemetry 2014 - ACDC Dynamics
Telemetry 2014 - ACDC Dynamics

... Z-8TC is an interface for thermocouple sensor type (J,K,E,N,S,R,B,T) and any generic sensor with mV signal output. The module has 8 input channels that are all independant of each other. The unit is a ModBUS Slave and can be coupled with any ModBUS Master device. 6 way isolation between power/ outpu ...
IOSR Journal of VLSI and Signal Processing (IOSR-JVSP)
IOSR Journal of VLSI and Signal Processing (IOSR-JVSP)

... grown all over the world. During the recent years. there is a great demand for portable devices like cellular phone , palm top computers, GPRS receivers, pocket calculator, and pacemakers. They all demand for low power. Hence low power design has emerged as a very attractive and fast development fie ...
AAT4285 数据资料DataSheet下载
AAT4285 数据资料DataSheet下载

... Functional Description The AAT4285 is a slew rate controlled P-channel MOSFET power switch designed for high-side load switching applications. The device operates with input voltages ranging from 3.0V to 13.2V, making it ideal for single- or multi-cell battery-powered applications. In cases where th ...
BRIDGE OPTIMIZATION FOR THERMISTOR DC = d~T = ~T (I) (2)
BRIDGE OPTIMIZATION FOR THERMISTOR DC = d~T = ~T (I) (2)

... phase-locked, or simple, are easily designed . Bandwidths may be limited to less than 100 Hz, which will keep input noise voltage well below the best available D.C. detectors. For systems where extr em ely high precision is necessary, the designer may consider using an A.C. voltage source to feed hi ...
STANDARD REVIEW PLAN
STANDARD REVIEW PLAN

... has neither been incorporated into the NRC’s regulations nor endorsed by a regulatory guide, licensees and applicants may consider and use the information in the referenced code or standard, if appropriately justified, consistent with current regulatory practice. Regulatory Guide 1.75, “Criteria fo ...
The Nishiki Amplifier
The Nishiki Amplifier

... 8°C/W type will do. All transistors should be mounted in such way that they are electrically isolated from the main heatsink and from each other; use dedicated isolation pads and isolated rings. The Baxandall diode D1 is added to create a better output symmetry. I chose for the 1N5060, but you could ...
Condition for Parallel Operation of Transformer
Condition for Parallel Operation of Transformer

... The current will be quite high as the leakage impedance is low. When the secondary windings are loaded, this circulating current will tend to produce unequal loading on the two transformers, and it may not be possible to take the full load from this group of two parallel transformers (one of the tra ...
Stakeholder Comparison Comment Rationale Matrix 2011-09-28 AESO AUTHORITATIVE DOCUMENT PROCESS
Stakeholder Comparison Comment Rationale Matrix 2011-09-28 AESO AUTHORITATIVE DOCUMENT PROCESS

... fault conditions and evaluate the above relay’s loadability at 0.85 per unit voltage and a power factor angle of 30 degrees. ...
this manual (in PDF format) refer to product model and version that
this manual (in PDF format) refer to product model and version that

electrical machines ii - SK Engineering Academy
electrical machines ii - SK Engineering Academy

... The winding factor kw is defined as the ratio of phasor addition of emf induced in all the coils of each phase winding to their arithmetic addition of emf’s. 9. Why are Alternators rated in kVA and not in kW? The continuous power rating of any machine is generally defined as the power of the machine ...
69 kV to 500 kV INTERCONNECTION REQUIREMENTS FOR
69 kV to 500 kV INTERCONNECTION REQUIREMENTS FOR

... BC Hydro has responsibility for the interconnection of facilities to the Transmission System including technical and operation criteria and processes. In certain cases (such as installation of revenue metering equipment), a review of plans and specifications by BC Hydro may also be required. BC Hydr ...
Model Validation for Wind Turbine Generator Models
Model Validation for Wind Turbine Generator Models

DSP-Based Field-Oriented Step Motor Control - CACT
DSP-Based Field-Oriented Step Motor Control - CACT

this PDF file
this PDF file

... (Fig. 8). Each bidirectional switch requires two control signals and puts out 4 signals indicating its state and current direction. This means that there are 54 signals handled by the controller at any moment. The control system has to work in real time in order to generate the switching pulses and ...
Ultralow IQ, 50mA LDO Linear Regulators w/Power
Ultralow IQ, 50mA LDO Linear Regulators w/Power

... The PG terminal for the fixed voltage option devices is an open drain, active-high output that indicates the status of VO (output of the LDO). When VO exceeds approximately 90% of the regulated voltage, PG goes to a high-impedance state. It goes to a low-impedance state when VO falls below approxima ...
INA118 数据资料 dataSheet 下载
INA118 数据资料 dataSheet 下载

ELEC 101 ELECTRIC CIRCUITS 1
ELEC 101 ELECTRIC CIRCUITS 1

... A hands-on study of devices and systems used in the control of industrial machinery. The student is introduced to the theory and use of electromechanical control circuits by use of traditional hardwire circuits. The programming of the Allen-Bradley Micro LoGix 1000 type of programmable logic contro ...
Zener Diodes
Zener Diodes

... In the previous Power Diodes tutorial we discussed ways of reducing the ripple or voltage variations on a direct DC voltage by connecting capacitors across the load resistance. While this method may be suitable for low power applications it is unsuitable to applications which need a "steady and smoo ...
AL80B manual
AL80B manual

... all Amateur bands from 160 through 15 meters. The AL-80BX and AL-80BY are export models that operate from 160 through 10 meters. Export modification instructions are available with proof of a valid amateur radio license. The AL-80B uses a single 3-500Z tube in a class AB2 grounded grid circuit. High ...
NaviTrack_Line_Trans..
NaviTrack_Line_Trans..

... hours depending on factors such as load and current transmitted. Other factors that affect the operation time will include chemistry of the battery. (Many of the new high performance batteries, such as the “Duracell ® ULTRA”, last 10%-20% longer than ...
700 Series AC Dielectric Test Sets  High Voltage AC Test Systems FEATURES
700 Series AC Dielectric Test Sets High Voltage AC Test Systems FEATURES

NCV890103 1.2 A, 2 MHz Automotive Buck Switching Regulator with RSTB
NCV890103 1.2 A, 2 MHz Automotive Buck Switching Regulator with RSTB

Modeling and Control of a Six-Switch Single-Phase Inverter - ETD-db
Modeling and Control of a Six-Switch Single-Phase Inverter - ETD-db

chapter 5
chapter 5

... one form or other to maintain the flow of electric current in desired paths or circuits. If due to some reason the current deviates from the desired path, the potential will drop. An example of this is a short circuit and this should always be avoided. This is done by proper choice and application o ...
< 1 ... 277 278 279 280 281 282 283 284 285 ... 1128 >

Power engineering



Power engineering, also called power systems engineering, is a subfield of energy engineering that deals with the generation, transmission, distribution and utilization of electric power and the electrical devices connected to such systems including generators, motors and transformers. Although much of the field is concerned with the problems of three-phase AC power – the standard for large-scale power transmission and distribution across the modern world – a significant fraction of the field is concerned with the conversion between AC and DC power and the development of specialized power systems such as those used in aircraft or for electric railway networks. It was a subfield of electrical engineering before the emergence of energy engineering.Electricity became a subject of scientific interest in the late 17th century with the work of William Gilbert. Over the next two centuries a number of important discoveries were made including the incandescent light bulb and the voltaic pile. Probably the greatest discovery with respect to power engineering came from Michael Faraday who in 1831 discovered that a change in magnetic flux induces an electromotive force in a loop of wire—a principle known as electromagnetic induction that helps explain how generators and transformers work.In 1881 two electricians built the world's first power station at Godalming in England. The station employed two waterwheels to produce an alternating current that was used to supply seven Siemens arc lamps at 250 volts and thirty-four incandescent lamps at 40 volts. However supply was intermittent and in 1882 Thomas Edison and his company, The Edison Electric Light Company, developed the first steam-powered electric power station on Pearl Street in New York City. The Pearl Street Station consisted of several generators and initially powered around 3,000 lamps for 59 customers. The power station used direct current and operated at a single voltage. Since the direct current power could not be easily transformed to the higher voltages necessary to minimise power loss during transmission, the possible distance between the generators and load was limited to around half-a-mile (800 m).That same year in London Lucien Gaulard and John Dixon Gibbs demonstrated the first transformer suitable for use in a real power system. The practical value of Gaulard and Gibbs' transformer was demonstrated in 1884 at Turin where the transformer was used to light up forty kilometres (25 miles) of railway from a single alternating current generator. Despite the success of the system, the pair made some fundamental mistakes. Perhaps the most serious was connecting the primaries of the transformers in series so that switching one lamp on or off would affect other lamps further down the line. Following the demonstration George Westinghouse, an American entrepreneur, imported a number of the transformers along with a Siemens generator and set his engineers to experimenting with them in the hopes of improving them for use in a commercial power system.One of Westinghouse's engineers, William Stanley, recognised the problem with connecting transformers in series as opposed to parallel and also realised that making the iron core of a transformer a fully enclosed loop would improve the voltage regulation of the secondary winding. Using this knowledge he built a much improved alternating current power system at Great Barrington, Massachusetts in 1886. In 1885 the Italian physicist and electrical engineer Galileo Ferraris demonstrated an induction motor and in 1887 and 1888 the Serbian-American engineer Nikola Tesla filed a range of patents related to power systems including one for a practical two-phase induction motor which Westinghouse licensed for his AC system.By 1890 the power industry had flourished and power companies had built thousands of power systems (both direct and alternating current) in the United States and Europe – these networks were effectively dedicated to providing electric lighting. During this time a fierce rivalry in the US known as the ""War of Currents"" emerged between Edison and Westinghouse over which form of transmission (direct or alternating current) was superior. In 1891, Westinghouse installed the first major power system that was designed to drive an electric motor and not just provide electric lighting. The installation powered a 100 horsepower (75 kW) synchronous motor at Telluride, Colorado with the motor being started by a Tesla induction motor. On the other side of the Atlantic, Oskar von Miller built a 20 kV 176 km three-phase transmission line from Lauffen am Neckar to Frankfurt am Main for the Electrical Engineering Exhibition in Frankfurt. In 1895, after a protracted decision-making process, the Adams No. 1 generating station at Niagara Falls began transmitting three-phase alternating current power to Buffalo at 11 kV. Following completion of the Niagara Falls project, new power systems increasingly chose alternating current as opposed to direct current for electrical transmission.Although the 1880s and 1890s were seminal decades in the field, developments in power engineering continued throughout the 20th and 21st century. In 1936 the first commercial high-voltage direct current (HVDC) line using mercury-arc valves was built between Schenectady and Mechanicville, New York. HVDC had previously been achieved by installing direct current generators in series (a system known as the Thury system) although this suffered from serious reliability issues. In 1957 Siemens demonstrated the first solid-state rectifier (solid-state rectifiers are now the standard for HVDC systems) however it was not until the early 1970s that this technology was used in commercial power systems. In 1959 Westinghouse demonstrated the first circuit breaker that used SF6 as the interrupting medium. SF6 is a far superior dielectric to air and, in recent times, its use has been extended to produce far more compact switching equipment (known as switchgear) and transformers. Many important developments also came from extending innovations in the ICT field to the power engineering field. For example, the development of computers meant load flow studies could be run more efficiently allowing for much better planning of power systems. Advances in information technology and telecommunication also allowed for much better remote control of the power system's switchgear and generators.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report