• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Manual PL512 - W-IE-NE
Manual PL512 - W-IE-NE

... All devices are intended for operation in control cabinets or in closed areas. The LAN connection and all wire connections between the different system parts must be done via shielded cable with conductive connector shells, which are fixed with screws. Furthermore, an additional fire-protective encl ...
AN149 Modeling and Loop Compensation Design of Switching
AN149 Modeling and Loop Compensation Design of Switching

... However, there are many reasons that can cause undesirable oscillation other than loop stability. Unfortunately, they all look the same on the oscilloscope to the inexperienced supply designer. Even for experienced engineers, sometimes identifying the reason that causes the instability can be diffic ...
DPA-Switch - akinoid.com
DPA-Switch - akinoid.com

Metal-Oxide Surge Arresters in High-Voltage Transmission
Metal-Oxide Surge Arresters in High-Voltage Transmission

... failure rates of metal-oxide arresters in transmission systems are close to zero), while at the same time the construction, compared with that of gapped SiC-arresters, has become less complicated and less prone to mechanical or dielectric defects. The next major step involved using polymeric materia ...
Baluns
Baluns

... • The two lengths of transmission line that comprise the balun need to have a characteristic impedance of ~ 100 ohms. RG-62 (Z = 95 ohms) works very well. • The length of the two sections of 100 ohm coax must be at least ¼ wavelength at the lowest frequency (approx 47 feet at 3.5 MHz) and a this typ ...
EE 1183340
EE 1183340

... Three-phase Induction motors have various advantages such as simple construction, reliable, rugged, low maintenance cost and lower manufacturing cost which has made induction motor popular to be used in many industrial applications. The major problem arises in this motor is their speed control as it ...
Two - Schneider Electric
Two - Schneider Electric

... an insulation fault experiences an indirect contact: the contact voltage Uc creates a current that passes through the human body. Maximum breaking time The maximum breaking time required by the installation standards, in the event of an insulation fault, depends on: bb the network voltage bb the ear ...
So what makes you think your compressor is “bad”?
So what makes you think your compressor is “bad”?

EXAMPLES OF STATOR WINDING PARTIAL DISCHARGE DUE TO INVERTER DRIVES
EXAMPLES OF STATOR WINDING PARTIAL DISCHARGE DUE TO INVERTER DRIVES

... Abstract: Random wound stator windings in motors have failed when exposed to the fast-risetime voltage surges coming from inverters. Measurements on motors show that these surges can create partial discharges and these discharges eventually destroy the turn-to-turn and/or phase-to-phase insulation, ...
Application Note 149 January 2015 Modeling and Loop Compensation Design of
Application Note 149 January 2015 Modeling and Loop Compensation Design of

... However, there are many reasons that can cause undesirable oscillation other than loop stability. Unfortunately, they all look the same on the oscilloscope to the inexperienced supply designer. Even for experienced engineers, sometimes identifying the reason that causes the instability can be diffic ...
Transformer Through Faults
Transformer Through Faults

... between faults, say five to ten years, or more, without significantly consuming the original manufactured ability to withstand through faults. This requires a transformer lifetime commitment by the end user to record and track significant events from the perspective of the transformer. In the world ...
design and real time implementation of control algorithm for
design and real time implementation of control algorithm for

... are normally mounted on a printed circuit board and fixed to the enclosure cap on the non-driving end. This enables users to adjust the complete assembly of Hall sensors to align with the rotor magnets in order to achieve the best performance. A new position sensor, such as a three branches vertical ...
Linear Actuator User Manual
Linear Actuator User Manual

Instruction Manual
Instruction Manual

... Requirements for Connection to the Telephone Network published by the industry’s Administrative Council for Terminal Attachments (ACTA). On the right side of this equipment is a label that contains, among other information, a product identifier in the format US:ICMOT03BIC-FR4000. If requested, this ...
A Survey on Instrumentation Amplifiers used for Biomedical
A Survey on Instrumentation Amplifiers used for Biomedical

... and testing purposes in bio-medical field. This amplification process is accomplished using bio-amplifiers such as operational amplifiers basically instrumentation amplifier. Instrumentation amplifiers serve as an important signal conditioning block at the front end for the amplification of bio sign ...
Installation Requirements for Conformance to Standards
Installation Requirements for Conformance to Standards

... Locally applicable grounding safety regulations and machinery directives shall be followed for providing a protective ground to earth. In addition, the following safety guidelines should be followed: 1. Ground conductors shall be as short and as large in size as possible. The conductors must always ...
FHR1200 Micro-Power, Ultra Wide Voltage Regulator FHR120 0 —
FHR1200 Micro-Power, Ultra Wide Voltage Regulator FHR120 0 —

... drive a power supply controller thus saving parts count and circuit complexity in many applications. This also makes the FHR1200 ideal for non-isolated secondary side, primary side, and floating regulation. Non-isolated secondary side regulation saves the cost of OPTOs and simplifies the power suppl ...
General class license
General class license

... With which of the following conditions must beacon stations comply? There must be no more than one beacon signal transmitting in the same band from the same station location The northern California DX Foundation (NCDXF) in cooperation with the International Amateur Radio Union (IARU) has constructed ...
OPERATING MANUAL NX Series Driver
OPERATING MANUAL NX Series Driver

PDF
PDF

... the same pure aluminum material, the low loss advantage of the SiC device could reduce the volume of forced air cooling systems by 65% (the total volume of the air cooling fan and fins). Figure 1 shows the prototype 400-V/3.7-kW class SiC inverter and SiC module. Overall dimensions of the SiC invert ...
Aalborg Universitet kA/1.1 kV Non-Destructive Testing Equipment
Aalborg Universitet kA/1.1 kV Non-Destructive Testing Equipment

... illustrated in Fig. 3. The NDT can provide both short-circuit types by different configuration and control timing schemes. Control timing schemes for the two types short-circuit will be further illustrated in Section II, Part 3. ...
CONSTAVOLT® FLOAT BATTERY CHARGER
CONSTAVOLT® FLOAT BATTERY CHARGER

... g. Remove personal metal items such as rings, bracelets, necklaces, and watches when working with a battery. A battery can produce a short-circuit current high enough to weld these items causing severe burns. h. NEVER charge a frozen battery. i. Do not use battery charger for charging dry-cell batte ...
MAX16961 3A, 2.2MHz, Synchronous Step-Down DC-DC Converter General Description
MAX16961 3A, 2.2MHz, Synchronous Step-Down DC-DC Converter General Description

... The MAX16961 is a high-efficiency, synchronous stepdown converter that operates with a 2.7V to 5.5V input voltage range and provides a 0.8V to 3.6V output voltage range. The wide input/output voltage range and the ability to provide up to 3A to load current make this device ideal for on-board point- ...
IXDD404 - IXYS Power
IXDD404 - IXYS Power

... In order for the design to turn the load off properly, the IXDD404 must be able to drain this 2.5A of current into an adequate grounding system. There are three paths for returning current that need to be considered: Path #1 is between the IXDD404 and it’s load. Path #2 is between the IXDD404 and it ...
Ind. Catalog_0730_r1.indd - Electro Rent Corporation
Ind. Catalog_0730_r1.indd - Electro Rent Corporation

... Whatever the size of your company, or the scope of your test equipment needs, Electro Rent has the solution. Electro Rent consistently provides the widest selection of test and measurement equipment available for rent, for lease and for sale used. Since 1965, we have been easy to work with, deliver ...
< 1 ... 243 244 245 246 247 248 249 250 251 ... 1128 >

Power engineering



Power engineering, also called power systems engineering, is a subfield of energy engineering that deals with the generation, transmission, distribution and utilization of electric power and the electrical devices connected to such systems including generators, motors and transformers. Although much of the field is concerned with the problems of three-phase AC power – the standard for large-scale power transmission and distribution across the modern world – a significant fraction of the field is concerned with the conversion between AC and DC power and the development of specialized power systems such as those used in aircraft or for electric railway networks. It was a subfield of electrical engineering before the emergence of energy engineering.Electricity became a subject of scientific interest in the late 17th century with the work of William Gilbert. Over the next two centuries a number of important discoveries were made including the incandescent light bulb and the voltaic pile. Probably the greatest discovery with respect to power engineering came from Michael Faraday who in 1831 discovered that a change in magnetic flux induces an electromotive force in a loop of wire—a principle known as electromagnetic induction that helps explain how generators and transformers work.In 1881 two electricians built the world's first power station at Godalming in England. The station employed two waterwheels to produce an alternating current that was used to supply seven Siemens arc lamps at 250 volts and thirty-four incandescent lamps at 40 volts. However supply was intermittent and in 1882 Thomas Edison and his company, The Edison Electric Light Company, developed the first steam-powered electric power station on Pearl Street in New York City. The Pearl Street Station consisted of several generators and initially powered around 3,000 lamps for 59 customers. The power station used direct current and operated at a single voltage. Since the direct current power could not be easily transformed to the higher voltages necessary to minimise power loss during transmission, the possible distance between the generators and load was limited to around half-a-mile (800 m).That same year in London Lucien Gaulard and John Dixon Gibbs demonstrated the first transformer suitable for use in a real power system. The practical value of Gaulard and Gibbs' transformer was demonstrated in 1884 at Turin where the transformer was used to light up forty kilometres (25 miles) of railway from a single alternating current generator. Despite the success of the system, the pair made some fundamental mistakes. Perhaps the most serious was connecting the primaries of the transformers in series so that switching one lamp on or off would affect other lamps further down the line. Following the demonstration George Westinghouse, an American entrepreneur, imported a number of the transformers along with a Siemens generator and set his engineers to experimenting with them in the hopes of improving them for use in a commercial power system.One of Westinghouse's engineers, William Stanley, recognised the problem with connecting transformers in series as opposed to parallel and also realised that making the iron core of a transformer a fully enclosed loop would improve the voltage regulation of the secondary winding. Using this knowledge he built a much improved alternating current power system at Great Barrington, Massachusetts in 1886. In 1885 the Italian physicist and electrical engineer Galileo Ferraris demonstrated an induction motor and in 1887 and 1888 the Serbian-American engineer Nikola Tesla filed a range of patents related to power systems including one for a practical two-phase induction motor which Westinghouse licensed for his AC system.By 1890 the power industry had flourished and power companies had built thousands of power systems (both direct and alternating current) in the United States and Europe – these networks were effectively dedicated to providing electric lighting. During this time a fierce rivalry in the US known as the ""War of Currents"" emerged between Edison and Westinghouse over which form of transmission (direct or alternating current) was superior. In 1891, Westinghouse installed the first major power system that was designed to drive an electric motor and not just provide electric lighting. The installation powered a 100 horsepower (75 kW) synchronous motor at Telluride, Colorado with the motor being started by a Tesla induction motor. On the other side of the Atlantic, Oskar von Miller built a 20 kV 176 km three-phase transmission line from Lauffen am Neckar to Frankfurt am Main for the Electrical Engineering Exhibition in Frankfurt. In 1895, after a protracted decision-making process, the Adams No. 1 generating station at Niagara Falls began transmitting three-phase alternating current power to Buffalo at 11 kV. Following completion of the Niagara Falls project, new power systems increasingly chose alternating current as opposed to direct current for electrical transmission.Although the 1880s and 1890s were seminal decades in the field, developments in power engineering continued throughout the 20th and 21st century. In 1936 the first commercial high-voltage direct current (HVDC) line using mercury-arc valves was built between Schenectady and Mechanicville, New York. HVDC had previously been achieved by installing direct current generators in series (a system known as the Thury system) although this suffered from serious reliability issues. In 1957 Siemens demonstrated the first solid-state rectifier (solid-state rectifiers are now the standard for HVDC systems) however it was not until the early 1970s that this technology was used in commercial power systems. In 1959 Westinghouse demonstrated the first circuit breaker that used SF6 as the interrupting medium. SF6 is a far superior dielectric to air and, in recent times, its use has been extended to produce far more compact switching equipment (known as switchgear) and transformers. Many important developments also came from extending innovations in the ICT field to the power engineering field. For example, the development of computers meant load flow studies could be run more efficiently allowing for much better planning of power systems. Advances in information technology and telecommunication also allowed for much better remote control of the power system's switchgear and generators.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report