• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Mitigation of voltage sags/swells to enhance Power Quality of
Mitigation of voltage sags/swells to enhance Power Quality of

... the series voltage injection and termination of the trigger pulses when the event has passed. The controller may also be used to shift the DC-AC inverter into rectifier mode to charge the capacitors in the DC energy link in the absence of voltage sags/swells. The dqo transformation or park’s transfo ...
sabre d18 32 - Grant Fidelity
sabre d18 32 - Grant Fidelity

PAM2306 Description Features Pin Assignments Applications
PAM2306 Description Features Pin Assignments Applications

... excellent stability and transient response. To ensure the longest battery life in portable applications, the PAM2306 provides a power saving Pulse-Skipping Modulation (PSM) mode to reduce quiescent current under light load operation. The PAM2306 supports a range of input voltages from 2.5V to 5.5V, ...
3021/3023 BuckPuck - LUXdrive LED Drivers
3021/3023 BuckPuck - LUXdrive LED Drivers

... The 3021/3023 Wide Range LED Power Module is a high efficiency dc to dc converter which delivers a fixed output current by varying the output voltage as required to maintain the specified current . A fast response current-sensing circuit permits the unit to be used in applications where flashing or ...
High Speed, Dual, 2 A MOSFET Driver ADP3629/ADP3630/ADP3631  FEATURES
High Speed, Dual, 2 A MOSFET Driver ADP3629/ADP3630/ADP3631 FEATURES

... rights of third parties that may result from its use. Specifications subject to change without notice. No license is granted by implication or otherwise under any patent or patent rights of Analog Devices. Trademarks and registered trademarks are the property of their respective owners. ...
HARDWARE MANUAL FX -30M/E-2AD
HARDWARE MANUAL FX -30M/E-2AD

Lab 5 Document (Word)
Lab 5 Document (Word)

... Previous labs demonstrate that the response of a system is modified by negative feedback control. The response speed of the system is increased as the proportional gain on the system increases. This was demonstrated using an electrical analog for a process. This section of the circuit represented a ...
CP2102 - Sparkfun
CP2102 - Sparkfun

Transformer Installation, Operation, and Maintenance Manual
Transformer Installation, Operation, and Maintenance Manual

... Altitude correction for application of a standard transformer in altitudes above 3300 feet can be made by reducing the load. Refer to Altitude Correction Factor in IEEE C57.96. ...
IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE)
IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE)

... The matrix converter (MC) is a single-stage power converter, capable of feeding an m-phase load from a n-phase source without using energy storage components. It is a direct frequency conversion device that generates variable magnitude variable frequency output voltage from the ac line. It has high ...
Document
Document

... will respond to high-side ground faults as long as the highside ground source remains connected. Further, and important to our investigation, it is commonly stated that because the normal power flow is toward the low-side, the 67P may be set more sensitively and possibly faster than traditional high ...
R.C.N. Pilawa-Podgurski, D. Giuliano, and D.J. Perreault, “Merged Two-Stage Power Converter Architecture with Soft Charging Switched-Capacitor Energy Transfer,” 2008 IEEE Power Electronics Specialists Conference , June 2008, pp. 4008 – 4015
R.C.N. Pilawa-Podgurski, D. Giuliano, and D.J. Perreault, “Merged Two-Stage Power Converter Architecture with Soft Charging Switched-Capacitor Energy Transfer,” 2008 IEEE Power Electronics Specialists Conference , June 2008, pp. 4008 – 4015

UMFT230XA Datasheet
UMFT230XA Datasheet

... The UMFT230XA is a development module for FTDI’s FT230XQ, one of the devices from FTDI’s range of USB interface bridging integrated circuit devices. FT230X is a USB to UART interface with a battery charger detection feature, which can allow batteries to be charged with a higher current from a dedica ...
XP125 INSTALLATION AND OPERATION MANUAL
XP125 INSTALLATION AND OPERATION MANUAL

Shaft Grounding and Sliding Electrical Contacts
Shaft Grounding and Sliding Electrical Contacts

... have been the many types of motors and generators that require power to the rotating part. The electrical and magnetic circuits in these machines inherently create a high potential for static and induced voltages. As the power capacities of these machines increased over the years the tendency for ac ...
MAX17083 Low-Voltage, Internal Switch, Step-Down Regulator General Description
MAX17083 Low-Voltage, Internal Switch, Step-Down Regulator General Description

... and reduced component count. External Schottky diodes are not required. An integrated boost switch eliminates the need for an external boost diode. The internal 25mΩ low-side power MOSFET easily supports continuous load currents up to 5A. The MAX17083 produces an adjustable 0.75V to 2.7V output volt ...
Advanced Generator Protection and Monitoring Using
Advanced Generator Protection and Monitoring Using

FAN5026  Dual DDR / Dual-Output PWM Controller F
FAN5026 Dual DDR / Dual-Output PWM Controller F

... controller intended for graphic chipset, SDRAM, DDR DRAM, or other low-voltage power applications in modern notebook, desktop, and sub-notebook PCs. The IC integrates control circuitry for two synchronous buck converters. The output voltage of each controller can be set in the range of 0.9V to 5.5V ...
Current control loop design and analysis based on resonant
Current control loop design and analysis based on resonant

Flyer E6 LCD RT Evolution
Flyer E6 LCD RT Evolution

... • Parallel installation: option to connect up to 3 UPS devices in redundant parallel mode (N+X) • Battery chargers: UPSs upward of 5 kVA are fitted with extendable chargers with 3 levels optimising battery performance as well as their recharge time and extending their useful life even further. In ad ...
Distribution High Impedance Fault Location Using Localized Voltage
Distribution High Impedance Fault Location Using Localized Voltage

... fires due to arcing and flashing at the point of contact [1]. Such faults in distribution systems affect more residential and commercial areas and are the focus of this work. To avoid such dangerous situations, quick and accurate fault detection and location techniques must be employed. Previously, me ...
LITERATURE REVIEW CHAPTER 2
LITERATURE REVIEW CHAPTER 2

... Chapter 1 dealt with the introduction to the research performed in this thesis. In this chapter, a literature review is presented to place this into context of available knowledge. A few key concepts seminal to this study are identified and presented. Firstly, basic concepts of power amplification a ...
Aalborg Universitet
Aalborg Universitet

... is required for the VSI to succeed in implementing the desired feature of each application. It is expected from any current or voltage regulator to [3],[4]: i) provide zero steady-state error; ii) accurately track the commanded reference during transients; iii) bandwidth as higher as possible; and i ...
full text pdf
full text pdf

... In the flyback converter, it is necessary to provide a good magnetic coupling between the primary and secondary windings. Failure to meet this requirement results in voltage spikes on the transistor, the elimination of which with the use of additional snubber circuit requires dissipation of the ener ...
Electrical Machines - Questions and Answers
Electrical Machines - Questions and Answers

... This type of relay will operate if single-phasing occurs at or near full load with the same time delay as on overload, but at light loads, the time delay for single-phase protection is longer. Another device is a phase-failure relay in the control gear. Its principle is based on the fact that the cu ...
< 1 ... 217 218 219 220 221 222 223 224 225 ... 1128 >

Power engineering



Power engineering, also called power systems engineering, is a subfield of energy engineering that deals with the generation, transmission, distribution and utilization of electric power and the electrical devices connected to such systems including generators, motors and transformers. Although much of the field is concerned with the problems of three-phase AC power – the standard for large-scale power transmission and distribution across the modern world – a significant fraction of the field is concerned with the conversion between AC and DC power and the development of specialized power systems such as those used in aircraft or for electric railway networks. It was a subfield of electrical engineering before the emergence of energy engineering.Electricity became a subject of scientific interest in the late 17th century with the work of William Gilbert. Over the next two centuries a number of important discoveries were made including the incandescent light bulb and the voltaic pile. Probably the greatest discovery with respect to power engineering came from Michael Faraday who in 1831 discovered that a change in magnetic flux induces an electromotive force in a loop of wire—a principle known as electromagnetic induction that helps explain how generators and transformers work.In 1881 two electricians built the world's first power station at Godalming in England. The station employed two waterwheels to produce an alternating current that was used to supply seven Siemens arc lamps at 250 volts and thirty-four incandescent lamps at 40 volts. However supply was intermittent and in 1882 Thomas Edison and his company, The Edison Electric Light Company, developed the first steam-powered electric power station on Pearl Street in New York City. The Pearl Street Station consisted of several generators and initially powered around 3,000 lamps for 59 customers. The power station used direct current and operated at a single voltage. Since the direct current power could not be easily transformed to the higher voltages necessary to minimise power loss during transmission, the possible distance between the generators and load was limited to around half-a-mile (800 m).That same year in London Lucien Gaulard and John Dixon Gibbs demonstrated the first transformer suitable for use in a real power system. The practical value of Gaulard and Gibbs' transformer was demonstrated in 1884 at Turin where the transformer was used to light up forty kilometres (25 miles) of railway from a single alternating current generator. Despite the success of the system, the pair made some fundamental mistakes. Perhaps the most serious was connecting the primaries of the transformers in series so that switching one lamp on or off would affect other lamps further down the line. Following the demonstration George Westinghouse, an American entrepreneur, imported a number of the transformers along with a Siemens generator and set his engineers to experimenting with them in the hopes of improving them for use in a commercial power system.One of Westinghouse's engineers, William Stanley, recognised the problem with connecting transformers in series as opposed to parallel and also realised that making the iron core of a transformer a fully enclosed loop would improve the voltage regulation of the secondary winding. Using this knowledge he built a much improved alternating current power system at Great Barrington, Massachusetts in 1886. In 1885 the Italian physicist and electrical engineer Galileo Ferraris demonstrated an induction motor and in 1887 and 1888 the Serbian-American engineer Nikola Tesla filed a range of patents related to power systems including one for a practical two-phase induction motor which Westinghouse licensed for his AC system.By 1890 the power industry had flourished and power companies had built thousands of power systems (both direct and alternating current) in the United States and Europe – these networks were effectively dedicated to providing electric lighting. During this time a fierce rivalry in the US known as the ""War of Currents"" emerged between Edison and Westinghouse over which form of transmission (direct or alternating current) was superior. In 1891, Westinghouse installed the first major power system that was designed to drive an electric motor and not just provide electric lighting. The installation powered a 100 horsepower (75 kW) synchronous motor at Telluride, Colorado with the motor being started by a Tesla induction motor. On the other side of the Atlantic, Oskar von Miller built a 20 kV 176 km three-phase transmission line from Lauffen am Neckar to Frankfurt am Main for the Electrical Engineering Exhibition in Frankfurt. In 1895, after a protracted decision-making process, the Adams No. 1 generating station at Niagara Falls began transmitting three-phase alternating current power to Buffalo at 11 kV. Following completion of the Niagara Falls project, new power systems increasingly chose alternating current as opposed to direct current for electrical transmission.Although the 1880s and 1890s were seminal decades in the field, developments in power engineering continued throughout the 20th and 21st century. In 1936 the first commercial high-voltage direct current (HVDC) line using mercury-arc valves was built between Schenectady and Mechanicville, New York. HVDC had previously been achieved by installing direct current generators in series (a system known as the Thury system) although this suffered from serious reliability issues. In 1957 Siemens demonstrated the first solid-state rectifier (solid-state rectifiers are now the standard for HVDC systems) however it was not until the early 1970s that this technology was used in commercial power systems. In 1959 Westinghouse demonstrated the first circuit breaker that used SF6 as the interrupting medium. SF6 is a far superior dielectric to air and, in recent times, its use has been extended to produce far more compact switching equipment (known as switchgear) and transformers. Many important developments also came from extending innovations in the ICT field to the power engineering field. For example, the development of computers meant load flow studies could be run more efficiently allowing for much better planning of power systems. Advances in information technology and telecommunication also allowed for much better remote control of the power system's switchgear and generators.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report