• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Pdf - Text of NPTEL IIT Video Lectures
Pdf - Text of NPTEL IIT Video Lectures

EL2001 Tech Sheet - Balboa Water Group
EL2001 Tech Sheet - Balboa Water Group

... the cover of the enclosure for the configured voltage. For 240V output W13 connects to Red AC and for 120V output W13 connects to White AC. The voltage to the ozone connector can be changed in the field if required. W13 just needs to be set for the required voltage. Balboa Ozone Generator: If the bo ...
2N4391 - Linear Systems
2N4391 - Linear Systems

section 262913 - enclosed controllers
section 262913 - enclosed controllers

... B. Coordinate sizes and locations of concrete bases with actual equipment provided. Cast anchor-bolt inserts into bases. Concrete, reinforcement, and formwork requirements are ...
TPS60230 数据资料 dataSheet 下载
TPS60230 数据资料 dataSheet 下载

... functions are turned off and the supply current is reduced to 0.1 µA. EN1 and EN2 can also be used for dimming. The logic levels at EN1 and EN2 set the minimum voltage at the current mirrors and the voltage at the ISET pin to GND. This sets the current at the LEDs to be either the full current or a ...
Balboa EL2001 Mach 3 v30 Hot Sheet
Balboa EL2001 Mach 3 v30 Hot Sheet

... the cover of the enclosure for the configured voltage. For 240V output W13 connects to Red AC and for 120V output W13 connects to White AC. The voltage to the ozone connector can be changed in the field if required. W13 just needs to be set for the required voltage. Balboa Ozone Generator: If the bo ...
26 24 13 Switchboards
26 24 13 Switchboards

... poles, with trip settings as shown. Breakers with frame sizes 250 amps and below shall have thermal-magnetic trip units and inverse time-current characteristics, or equal. 6. Provide breakers 400-amp frame and larger with an electronic solid state programmable trip unit. For four-wire power systems ...
LTC3400-1 - 600mA, 1.2MHz Micropower Synchronous Boost
LTC3400-1 - 600mA, 1.2MHz Micropower Synchronous Boost

... Note 1: Absolute Maximum Ratings are those values beyond which the life of a device may be impaired. Note 2: The LTC3400-1 is guaranteed to meet performance specifications from 0°C to 70°C. Specifications over the – 30°C to 85°C operating temperature range are assured by design, characterization and ...
4.5V to 18V Input, 5A/5A Dual Synchronous
4.5V to 18V Input, 5A/5A Dual Synchronous

... TPS65279V features dedicated enable pin when I2C interface is not used. Independent soft-start pin provides flexibility in power up programmability. Constant frequency peak current mode control simplifies the compensation and provides fast transient response. Cycle-by-cycle over current protection a ...
AHCAL_Electr_Daegu09_update
AHCAL_Electr_Daegu09_update

... HBU redesign needs input of tile shape and SPIROC pinout. -DIF (replace commercial board). Firmware development has to take place ‚step-by-step‘ in parallel to DAQ-DIF setup. Flexleads, CALIB and POWER could be used for final setup (to be discussed). B. Lutz ...
T551 Series
T551 Series

4.5V to 18V Input, 5A/5A Dual Synchronous Step
4.5V to 18V Input, 5A/5A Dual Synchronous Step

... TPS65279V features dedicated enable pin when I2C interface is not used. Independent soft-start pin provides flexibility in power up programmability. Constant frequency peak current mode control simplifies the compensation and provides fast transient response. Cycle-by-cycle over current protection a ...
Electric Circuits
Electric Circuits

EGEE
EGEE

... custom ASIC for the implementation of the power controller and switches in a known, radiation qualified technology Error! Reference source not found.. The LHC trackers operate with magnetic fields up to 4 T to bend the particles thus allowing their identification. The DC-DC converters will be expose ...
A1000 Cheat Sheet (Closed Loop Operation)
A1000 Cheat Sheet (Closed Loop Operation)

Development of Compound Semiconductor Devices— In Search of
Development of Compound Semiconductor Devices— In Search of

... with two different semiconductors are called a hetero-junction, and the method of crystal growth of semiconductor with very few defects is called epitaxial growth method (epitaxy). The origin of the word “epitaxy” is Greek; “epi-” means “on” and “taxis” means “lining-up.” Therefore epitaxy means lin ...
File - Tigard High Automotive Technology
File - Tigard High Automotive Technology

... • Wound coils are known as coil-wrapped loads. These are used in electrical load devices, such as starters, relays, ignition coils, wiper motors, gauges, and alternators. Wound coils function according to three basic magnetic principles. If a current is being forced through a conductor, a magnetic f ...
Data Sheet - ROHM Semiconductor
Data Sheet - ROHM Semiconductor

MOSFET firing circuit class notes
MOSFET firing circuit class notes

... Smaller L’s and C’s permit smaller, lighter circuits. • Correspondingly, L and C rms ripple currents decrease, so current ratings can be lower. Thus, smaller, lighter circuits. • AC transformers are smaller because, for a given voltage rating, the peak flux density in the core is reduced (which mean ...
ADR291 数据手册DataSheet 下载
ADR291 数据手册DataSheet 下载

... voltage references that use an XFET® reference circuit. The new XFET architecture offers significant performance improvements over traditional band gap and buried Zener-based references. Improvements include one quarter the voltage noise output of band gap references operating at the same current, v ...
Bovie A1250 - World Precision Instruments
Bovie A1250 - World Precision Instruments

... Connect the power cord to a properly polarized and grounded power source with the frequency and voltage characteristics that match those listed on the back of the unit. Electric Shock Hazard - Connect the generator power cord to a properly grounded receptacle. Do not use power plug adapters. Electri ...
General Description Features
General Description Features

... The EV kit features a 2-pin jumper (JU5) to set the IC’s initial startup legacy operational mode. In legacy mode, PD signature capacitances up to 47FF (typ) are accepted. Table 6 lists the jumper options. Refer to the MAX5971A IC data sheet for more information. AC-Disconnect Monitoring Oscillator a ...
BD1482EFJ
BD1482EFJ

... ・The thermal Pad on the back side of IC has the great thermal conduction to the chip. So using the GND plain as broad and wide as possible can help thermal dissipation. And a lot of thermal via for helping the spread of heat to the different layer is also effective. ・The input capacitors should be c ...
PDF
PDF

... both bit line and inverse bit line and then the word line is enabled, due to this these word line the access transistor are enabled. The value stored are transferred to bit line leaving bit line to its pre charge value and discharge inverse bit line through N1 and N2 to logical 0. [1] During standby ...
ZXTP19020DZ Features Mechanical Data
ZXTP19020DZ Features Mechanical Data

... hold Diodes Incorporated and its representatives harmless against all claims, damages, expenses, and attorney fees arising out of, directly or indirectly, any claim of personal injury or death associated with such unintended or unauthorized application. Products described herein may be covered by on ...
< 1 ... 159 160 161 162 163 164 165 166 167 ... 1128 >

Power engineering



Power engineering, also called power systems engineering, is a subfield of energy engineering that deals with the generation, transmission, distribution and utilization of electric power and the electrical devices connected to such systems including generators, motors and transformers. Although much of the field is concerned with the problems of three-phase AC power – the standard for large-scale power transmission and distribution across the modern world – a significant fraction of the field is concerned with the conversion between AC and DC power and the development of specialized power systems such as those used in aircraft or for electric railway networks. It was a subfield of electrical engineering before the emergence of energy engineering.Electricity became a subject of scientific interest in the late 17th century with the work of William Gilbert. Over the next two centuries a number of important discoveries were made including the incandescent light bulb and the voltaic pile. Probably the greatest discovery with respect to power engineering came from Michael Faraday who in 1831 discovered that a change in magnetic flux induces an electromotive force in a loop of wire—a principle known as electromagnetic induction that helps explain how generators and transformers work.In 1881 two electricians built the world's first power station at Godalming in England. The station employed two waterwheels to produce an alternating current that was used to supply seven Siemens arc lamps at 250 volts and thirty-four incandescent lamps at 40 volts. However supply was intermittent and in 1882 Thomas Edison and his company, The Edison Electric Light Company, developed the first steam-powered electric power station on Pearl Street in New York City. The Pearl Street Station consisted of several generators and initially powered around 3,000 lamps for 59 customers. The power station used direct current and operated at a single voltage. Since the direct current power could not be easily transformed to the higher voltages necessary to minimise power loss during transmission, the possible distance between the generators and load was limited to around half-a-mile (800 m).That same year in London Lucien Gaulard and John Dixon Gibbs demonstrated the first transformer suitable for use in a real power system. The practical value of Gaulard and Gibbs' transformer was demonstrated in 1884 at Turin where the transformer was used to light up forty kilometres (25 miles) of railway from a single alternating current generator. Despite the success of the system, the pair made some fundamental mistakes. Perhaps the most serious was connecting the primaries of the transformers in series so that switching one lamp on or off would affect other lamps further down the line. Following the demonstration George Westinghouse, an American entrepreneur, imported a number of the transformers along with a Siemens generator and set his engineers to experimenting with them in the hopes of improving them for use in a commercial power system.One of Westinghouse's engineers, William Stanley, recognised the problem with connecting transformers in series as opposed to parallel and also realised that making the iron core of a transformer a fully enclosed loop would improve the voltage regulation of the secondary winding. Using this knowledge he built a much improved alternating current power system at Great Barrington, Massachusetts in 1886. In 1885 the Italian physicist and electrical engineer Galileo Ferraris demonstrated an induction motor and in 1887 and 1888 the Serbian-American engineer Nikola Tesla filed a range of patents related to power systems including one for a practical two-phase induction motor which Westinghouse licensed for his AC system.By 1890 the power industry had flourished and power companies had built thousands of power systems (both direct and alternating current) in the United States and Europe – these networks were effectively dedicated to providing electric lighting. During this time a fierce rivalry in the US known as the ""War of Currents"" emerged between Edison and Westinghouse over which form of transmission (direct or alternating current) was superior. In 1891, Westinghouse installed the first major power system that was designed to drive an electric motor and not just provide electric lighting. The installation powered a 100 horsepower (75 kW) synchronous motor at Telluride, Colorado with the motor being started by a Tesla induction motor. On the other side of the Atlantic, Oskar von Miller built a 20 kV 176 km three-phase transmission line from Lauffen am Neckar to Frankfurt am Main for the Electrical Engineering Exhibition in Frankfurt. In 1895, after a protracted decision-making process, the Adams No. 1 generating station at Niagara Falls began transmitting three-phase alternating current power to Buffalo at 11 kV. Following completion of the Niagara Falls project, new power systems increasingly chose alternating current as opposed to direct current for electrical transmission.Although the 1880s and 1890s were seminal decades in the field, developments in power engineering continued throughout the 20th and 21st century. In 1936 the first commercial high-voltage direct current (HVDC) line using mercury-arc valves was built between Schenectady and Mechanicville, New York. HVDC had previously been achieved by installing direct current generators in series (a system known as the Thury system) although this suffered from serious reliability issues. In 1957 Siemens demonstrated the first solid-state rectifier (solid-state rectifiers are now the standard for HVDC systems) however it was not until the early 1970s that this technology was used in commercial power systems. In 1959 Westinghouse demonstrated the first circuit breaker that used SF6 as the interrupting medium. SF6 is a far superior dielectric to air and, in recent times, its use has been extended to produce far more compact switching equipment (known as switchgear) and transformers. Many important developments also came from extending innovations in the ICT field to the power engineering field. For example, the development of computers meant load flow studies could be run more efficiently allowing for much better planning of power systems. Advances in information technology and telecommunication also allowed for much better remote control of the power system's switchgear and generators.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report