• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
1 - Cooper Industries
1 - Cooper Industries

... specification, shall be in accordance with the latest revision of the following ANSI/IEEE, Department of Energy, and NEMA standards. C57.12.00 – IEEE Standard for Standard General Requirements for Liquid-Immersed Distribution, Power, and Regulating Transformers C57.12.10 – Safety Requirements 230 kV ...
SL1000 High-Speed Data Acquisition Unit IM 720120-01E 1st Edition
SL1000 High-Speed Data Acquisition Unit IM 720120-01E 1st Edition

... The general safety precautions described herein must be observed during all phases of operation. If the instrument is used in a manner not specified in this manual, the protection provided by the instrument may be impaired. Yokogawa Electric Corporation assumes no liability for the customer’s failur ...
BD8306MUV
BD8306MUV

... ROHM’s highly-efficient buck-boost converter BD8306MUV produces step-up/down output voltage including 3.3 V from two-cell or three-cell alkaline battery, or one-cell lithium-ion battery with just one inductor. This IC adopts an original step-up/down drive system and creates a higher efficient power ...
PDF: 1.54MB
PDF: 1.54MB

... transfer mold package favorable for larger mass production. Power chips, drive and protection circuits are integrated in the module, which make it easy for AC100-240V class low power motor inverter control. DIP Ver.6 takes over the functions of conventional DIP Ver.5 (such as incorporating bootstrap ...
Aalborg Universitet Thermal Coupling and Different Heating/Cooling Conditions
Aalborg Universitet Thermal Coupling and Different Heating/Cooling Conditions

... power module occur on the interconnection of the bond-wires to the Silicon chips and in the soldering layers. So, the critical points are set to the junction layer on the Silicon chips and two solder layers beneath the chips and solder layer beneath the DCB. These critical points are shown in Fig. 4 ...
6.0 selecting, installing, maintenance & troubleshooting
6.0 selecting, installing, maintenance & troubleshooting

... voltage drop from the inrush current that flows when other equipment is turned on. -When several CPM*A PLCs are being used, it is recommended to wire the PCs on separate circuits to prevent a voltage drop from the inrush current @ incorrect operation of the circuit breaker. -Use twisted power supply ...
TRIGGERED CURRENT LIMITERS FOR CLOSING BUS TIES
TRIGGERED CURRENT LIMITERS FOR CLOSING BUS TIES

NCP1230A - Low-Standby Power Soft Skip Mode Controller
NCP1230A - Low-Standby Power Soft Skip Mode Controller

... standby power in medium--to--high power Switched--Mode Power Supplies such as notebook adapters, off--line battery chargers and consumer electronics equipment. Housed in a compact 8--pin package (SO--8 or PDIP--7), the NCP1230A contains all needed control functionality to build a rugged and efficien ...
pancake generator - Marathon Electric
pancake generator - Marathon Electric

Sigma-II SERIES SGDH FULLY CLOSED INTERFACE
Sigma-II SERIES SGDH FULLY CLOSED INTERFACE

TPS6513x Positive and Negative Output DC-DC
TPS6513x Positive and Negative Output DC-DC

... The TPS6513x is dual-output DC-DC converter generating a positive output voltage up to 15 V and a negative output voltage down to –15 V with output currents in a 200-mA range in typical applications, depending on input voltage to output voltage ratio. With a total efficiency up to 85%, the device is ...
NCP5181BAL36WEVB NCP5181 36 W Ballast Evaluation Board User's Manual
NCP5181BAL36WEVB NCP5181 36 W Ballast Evaluation Board User's Manual

... are registered trademarks of Semiconductor Components Industries, LLC (SCILLC). SCILLC owns the rights to a number of patents, trademarks, copyrights, trade secrets, and other intellectual property. A listing of SCILLC’s product/patent coverage may be accessed at www.onsemi.com/site/pdf/Patent−Marki ...
50 performance analysis of pid controller for three- phase
50 performance analysis of pid controller for three- phase

... supplying a DC voltage of 400V to the three-phase inverter. Pulse-width modulation (PWM) technique is used to generate switching signal to the insulated gate bipolar transistors (IGBTs) of the three-phase inverter. The six number of IGBTs in the three-phase inverter are all of same rating and they a ...
Liebert NXL System Control Cabinet , SCCi
Liebert NXL System Control Cabinet , SCCi

... Under typical operation and with all doors closed, only normal safety precautions are necessary. The area around the system should be kept free of puddles of water, excess moisture and debris. Only test equipment designed for troubleshooting should be used. This is particularly true for oscilloscope ...
Note 2
Note 2

electronic instrumentation
electronic instrumentation

Audio Amplifiers
Audio Amplifiers

Summary of risks with conductive and non-conductive plastic
Summary of risks with conductive and non-conductive plastic

... The capacitative coupling between the surface charge and the earthed lining will reduce the voltages generated by rubbing the pipe surface. Hence the risk of incendiary sparks or brush discharges due to rubbing will be lower than with an insulating pipe. However, the insulating outer part of the pip ...
Principles of Electrical Grounding
Principles of Electrical Grounding

... The short circuit current is conducted away through the low impedance path. In this figure we illustrate another problem that of a high impedance connection between the building steel and the power ground. Sally will still be safe but the motor will fail. Due to the high impedance, the fault current ...
e-roll player system installation manual  - Spencer`s E
e-roll player system installation manual - Spencer`s E

... play them much more often and for longer periods of time than before they installed the system. Unfortunately, most of the electric pump motors in these instruments are over 70 years old and have not had the benefit of regular lubrication, cleaning and maintenance. When motors have not been regularl ...
Tender for COEWET-Tech II Rev 201.
Tender for COEWET-Tech II Rev 201.

... Part B of the Bid will be commercial bid that shall comprise the cost details, in format given in Annexure 5. Total cost of the item and accessories required for effective functioning of the equipment / item, including the control system, printer, packaging & forwarding, taxes etc. shall be duly fil ...
Texas Instruments DRV8834 stepper motor driver datasheet
Texas Instruments DRV8834 stepper motor driver datasheet

... N-channel power MOSFETs configured as an Hbridge to drive the motor windings. Each H-bridge includes circuitry to regulate or limit the winding current. With proper PCB design, each H-bridge of the DRV8834 can driving up to 1.5-A RMS (or DC) continuously, at 25°C with a VM supply of 5 V. The device ...
MAX8620Y µPMIC for Microprocessors or DSPs in Portable Equipment General Description
MAX8620Y µPMIC for Microprocessors or DSPs in Portable Equipment General Description

... DSPs in portable devices. The µPMIC includes a highefficiency step-down DC-DC converter, two lowdropout linear regulators (LDOs), a microprocessor reset output, and power-on/off control logic. This device maintains high efficiency at light loads with a low 115µA supply current, and its miniature TDF ...
Factors To Consider In Selecting Electric Motors
Factors To Consider In Selecting Electric Motors

Device circuit breakers - the basics
Device circuit breakers - the basics

... the selectivity between the individual fuses and protective devices must be maintained. This also ensures higher system availability as only the faulty circuit is switched off. Device circuit breakers should be easily accessible when installed in control cabinets, so that they can be switched on aga ...
< 1 ... 96 97 98 99 100 101 102 103 104 ... 1128 >

Power engineering



Power engineering, also called power systems engineering, is a subfield of energy engineering that deals with the generation, transmission, distribution and utilization of electric power and the electrical devices connected to such systems including generators, motors and transformers. Although much of the field is concerned with the problems of three-phase AC power – the standard for large-scale power transmission and distribution across the modern world – a significant fraction of the field is concerned with the conversion between AC and DC power and the development of specialized power systems such as those used in aircraft or for electric railway networks. It was a subfield of electrical engineering before the emergence of energy engineering.Electricity became a subject of scientific interest in the late 17th century with the work of William Gilbert. Over the next two centuries a number of important discoveries were made including the incandescent light bulb and the voltaic pile. Probably the greatest discovery with respect to power engineering came from Michael Faraday who in 1831 discovered that a change in magnetic flux induces an electromotive force in a loop of wire—a principle known as electromagnetic induction that helps explain how generators and transformers work.In 1881 two electricians built the world's first power station at Godalming in England. The station employed two waterwheels to produce an alternating current that was used to supply seven Siemens arc lamps at 250 volts and thirty-four incandescent lamps at 40 volts. However supply was intermittent and in 1882 Thomas Edison and his company, The Edison Electric Light Company, developed the first steam-powered electric power station on Pearl Street in New York City. The Pearl Street Station consisted of several generators and initially powered around 3,000 lamps for 59 customers. The power station used direct current and operated at a single voltage. Since the direct current power could not be easily transformed to the higher voltages necessary to minimise power loss during transmission, the possible distance between the generators and load was limited to around half-a-mile (800 m).That same year in London Lucien Gaulard and John Dixon Gibbs demonstrated the first transformer suitable for use in a real power system. The practical value of Gaulard and Gibbs' transformer was demonstrated in 1884 at Turin where the transformer was used to light up forty kilometres (25 miles) of railway from a single alternating current generator. Despite the success of the system, the pair made some fundamental mistakes. Perhaps the most serious was connecting the primaries of the transformers in series so that switching one lamp on or off would affect other lamps further down the line. Following the demonstration George Westinghouse, an American entrepreneur, imported a number of the transformers along with a Siemens generator and set his engineers to experimenting with them in the hopes of improving them for use in a commercial power system.One of Westinghouse's engineers, William Stanley, recognised the problem with connecting transformers in series as opposed to parallel and also realised that making the iron core of a transformer a fully enclosed loop would improve the voltage regulation of the secondary winding. Using this knowledge he built a much improved alternating current power system at Great Barrington, Massachusetts in 1886. In 1885 the Italian physicist and electrical engineer Galileo Ferraris demonstrated an induction motor and in 1887 and 1888 the Serbian-American engineer Nikola Tesla filed a range of patents related to power systems including one for a practical two-phase induction motor which Westinghouse licensed for his AC system.By 1890 the power industry had flourished and power companies had built thousands of power systems (both direct and alternating current) in the United States and Europe – these networks were effectively dedicated to providing electric lighting. During this time a fierce rivalry in the US known as the ""War of Currents"" emerged between Edison and Westinghouse over which form of transmission (direct or alternating current) was superior. In 1891, Westinghouse installed the first major power system that was designed to drive an electric motor and not just provide electric lighting. The installation powered a 100 horsepower (75 kW) synchronous motor at Telluride, Colorado with the motor being started by a Tesla induction motor. On the other side of the Atlantic, Oskar von Miller built a 20 kV 176 km three-phase transmission line from Lauffen am Neckar to Frankfurt am Main for the Electrical Engineering Exhibition in Frankfurt. In 1895, after a protracted decision-making process, the Adams No. 1 generating station at Niagara Falls began transmitting three-phase alternating current power to Buffalo at 11 kV. Following completion of the Niagara Falls project, new power systems increasingly chose alternating current as opposed to direct current for electrical transmission.Although the 1880s and 1890s were seminal decades in the field, developments in power engineering continued throughout the 20th and 21st century. In 1936 the first commercial high-voltage direct current (HVDC) line using mercury-arc valves was built between Schenectady and Mechanicville, New York. HVDC had previously been achieved by installing direct current generators in series (a system known as the Thury system) although this suffered from serious reliability issues. In 1957 Siemens demonstrated the first solid-state rectifier (solid-state rectifiers are now the standard for HVDC systems) however it was not until the early 1970s that this technology was used in commercial power systems. In 1959 Westinghouse demonstrated the first circuit breaker that used SF6 as the interrupting medium. SF6 is a far superior dielectric to air and, in recent times, its use has been extended to produce far more compact switching equipment (known as switchgear) and transformers. Many important developments also came from extending innovations in the ICT field to the power engineering field. For example, the development of computers meant load flow studies could be run more efficiently allowing for much better planning of power systems. Advances in information technology and telecommunication also allowed for much better remote control of the power system's switchgear and generators.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report