• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Simple power rail sequencing solutions for complex multi
Simple power rail sequencing solutions for complex multi

... other intellectual property right relating to any combination, machine, or process in which TI components or services are used. Information published by TI regarding third-party products or services does not constitute a license to use such products or services or a warranty or endorsement thereof. ...
UM1491
UM1491

... Current sensing amplifying network . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 Brake circuit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 Example of isolation circuit for Triac-ba ...
Diesel-Electric Propulsion Systems
Diesel-Electric Propulsion Systems

... torque and direction of rotation with feed back of the reverse power to the main alternators and to the mains respectively to braking resistors in case of reversing manoeuvre and n Continuous speed control from 0 to 100 % of rated speed All operation requirements are achieved automatical ...
Electronics Powerpoint
Electronics Powerpoint

... transistors) and with electronic devices ...
High Voltage Direct Current Electricity – technical
High Voltage Direct Current Electricity – technical

... AC equipment can exceed its current rating for short periods before the conducting elements become too hot. This can allow the system operator valuable time to reconfigure the network and return power flows to normal levels. ...
VI. Wye-Broken-Delta Vt, Ground Overvoltage Protection
VI. Wye-Broken-Delta Vt, Ground Overvoltage Protection

Resistors - TT Electronics
Resistors - TT Electronics

PowerPac™ Basic Power Supply Instruction Manual - Bio-Rad
PowerPac™ Basic Power Supply Instruction Manual - Bio-Rad

... unit equilibrate to room temperature for a minimum of 2 hours before using it. 6. Never connect a high voltage output lead to earth ground. This defeats the floating electrical isolation of the power supply and exposes the user to potentially lethal high voltages. ...
EX2100e Excitation Control 100, 77, 53, and 42 mm Thyristor Systems
EX2100e Excitation Control 100, 77, 53, and 42 mm Thyristor Systems

... rectifier bridge includes thyristor protection circuitry, such as snubbers, filters, and fuses. The thyristor bridge module is forced-air cooled. For most applications, redundant cooling modules that are normally energized during operation are used. A thermistor monitors the PCM temperature. A set o ...
Design And Verification of A PLL Based Clock And Data Recovery
Design And Verification of A PLL Based Clock And Data Recovery

AAT4625 数据资料DataSheet下载
AAT4625 数据资料DataSheet下载

... AAT4625 at high temperature. RJA is the thermal resistance between the device die and the board onto which it is mounted. TA(MAX) is the maximum ambient temperature for the printed circuit board assembly under the AAT4625 when the load switch is not dissipating power. Equation 1 can be transformed ...
Selection of scheme
Selection of scheme

Answer all questions PART A – (10*2=20marks) 1. What are the
Answer all questions PART A – (10*2=20marks) 1. What are the

... UNIT – I MOS TRANSISTOR THEORY AND PROCESS TECHNOLOGY PART A (2 Marks) 1. What is meant by “Epitaxy”? 2. What is isolation? 3. What is the special feature of Twin-Tub process? 4. What are the various processes used in SOI? 5. What is siliside? 6. What is LDD? 7. What is LOCOS? 8. Give the advantages ...
ESD Testing of MOS Gated Power Transistors
ESD Testing of MOS Gated Power Transistors

... similar tendency to "walk out." If this leakage was contained within 100 microA or so, the gate would not be damaged. To verify this, 11 devices where "gate avalanched" and then tested on the ESD tester of Figure 6. Their failure points were in the same range as those of 12 devices from the same lot ...
Printed Circuit Board Layout
Printed Circuit Board Layout

... integrity or on radiated emissions. A gap in position 1 however, could result in significant problems. Current returning on the plane under the trace is forced to go around the gap. This significantly increases the signal loop area. At low frequencies (generally kHz frequencies and below), the resis ...
chapter 6: earthing system tn systems
chapter 6: earthing system tn systems

... 3) unearthed (or impedance-earthed) neutral IT ...
Building Circuits Overview Directions
Building Circuits Overview Directions

... Ask: Why is electricity able to flow through a wire? Explain that wire is made of metal and metal is a good conductor of electricity. Ask the class to predict what kinds of materials they think electricity will flow through easily and what materials electricity will not flow through easily. Remind t ...
Complete PDF Edition (762 KB)
Complete PDF Edition (762 KB)

... the manufacturing technologies available in 1978, an element life of 1 ~ 2 years was considered acceptable. Lower protection levels also require arrestors to absorb the energy of switching surges associated with circuit breaker activity and power-frequency temporary overvoltage (TOV) associated with ...
Circuit Note - uri=media.digikey
Circuit Note - uri=media.digikey

Circuit breaker II updated
Circuit breaker II updated

... • When the circuit breaker is required to isolate the faulty part, the moving contact moves to interrupt the circuit. • On the separation of the contacts, the flow of current is interrupted, resulting in the formation of arc between the contacts. The contacts are placed in a closed chamber containin ...
Relocatable Power Taps “RPT`s”
Relocatable Power Taps “RPT`s”

... receptacles for computers, audio and video equipment and other equipment”. There are many ways to misuse these devices and numerous standards which apply. Unfortunately, an all too typically found misuse of the device finds inappropriate loads plugged into it. Examples of such inappropriate loads in ...
Sizing Current Transformers Rating To Enhance Voltage Model
Sizing Current Transformers Rating To Enhance Voltage Model

v. high speed clock oscillation circuit
v. high speed clock oscillation circuit

I. Ch 4 The System Unit
I. Ch 4 The System Unit

... Flash RAM (aka Flash memory) is a new type of RAM that is nonvolatile and can retain data even if power is switched off. This type of memory is more expensive are used in digital cell phones, digital cameras, and some portable computers. It is important to have enough RAM. If your computer does not ...
Before You Begin: Assign Information Classification
Before You Begin: Assign Information Classification

... There are many case designs to choose from if it is necessary to have a case that is attractive. LED indicators that are mounted on the front of the case can tell you if the system is receiving power, when the hard drive is being used, and when the computer is on standby or sleeping. All cases have ...
< 1 ... 88 89 90 91 92 93 94 95 96 ... 256 >

Fault tolerance



Fault tolerance is the property that enables a system to continue operating properly in the event of the failure of (or one or more faults within) some of its components. If its operating quality decreases at all, the decrease is proportional to the severity of the failure, as compared to a naively designed system in which even a small failure can cause total breakdown. Fault tolerance is particularly sought after in high-availability or life-critical systems.A fault-tolerant design enables a system to continue its intended operation, possibly at a reduced level, rather than failing completely, when some part of the system fails. The term is most commonly used to describe computer systems designed to continue more or less fully operational with, perhaps, a reduction in throughput or an increase in response time in the event of some partial failure. That is, the system as a whole is not stopped due to problems either in the hardware or the software. An example in another field is a motor vehicle designed so it will continue to be drivable if one of the tires is punctured. A structure is able to retain its integrity in the presence of damage due to causes such as fatigue, corrosion, manufacturing flaws, or impact.Within the scope of an individual system, fault tolerance can be achieved by anticipating exceptional conditions and building the system to cope with them, and, in general, aiming for self-stabilization so that the system converges towards an error-free state. However, if the consequences of a system failure are catastrophic, or the cost of making it sufficiently reliable is very high, a better solution may be to use some form of duplication. In any case, if the consequence of a system failure is so catastrophic, the system must be able to use reversion to fall back to a safe mode. This is similar to roll-back recovery but can be a human action if humans are present in the loop.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report