• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Chapter 320 - Electric Power Distribution Systems
Chapter 320 - Electric Power Distribution Systems

... ondary and single-phase, three wire grounded outlets with two pole ground fault current interruption (GFCI) protection are provided where required by the user equipment (see paragraph 320-1.2.1.3). Only one ground connection point is allowed for each grounded power system. Ungrounded electrical syst ...
Merlin Gerin Masterpact Earthing Switch
Merlin Gerin Masterpact Earthing Switch

Radiation-Hard/High-Speed Parallel Optical Links  K.K. Gan, P. Buchholz,
Radiation-Hard/High-Speed Parallel Optical Links K.K. Gan, P. Buchholz,

... is enabled by readily available high-speed VCSEL arrays. With the use of a 12-channel array operating at 10 Gb/s per channel, a parallel optical engine can deliver an aggregate bandwidth of 120 Gb/s. With a standard spacing of 250 µm between VCSELs, the width of a 12-channel array is only slightly o ...
VACUUM TYPE 15 PANELS, 11 kV SWITCH BOARDS
VACUUM TYPE 15 PANELS, 11 kV SWITCH BOARDS

... ACCEPTABLE. The panels shall have a degree of protection of IP-4x. The leads from metering CTs shall be directly terminated at TTB & there from at the KWH meter/SEM with a provision to seal TTB and KWH meter/SEM. The said CT leads will be concealed to prevent their tempering enroute. Similarly PT le ...
CA‐NLH‐037  NLH 2016 Capital Budget Application  Page 1 of 1 Volume III, Tab 19 – Replace Protective Relays 
CA‐NLH‐037  NLH 2016 Capital Budget Application  Page 1 of 1 Volume III, Tab 19 – Replace Protective Relays 

... transformer including the breaker where applicable and the Protection B relay is to use the next CT set inward. The relay settings are applied in the same way to both relays, therefore both relays should operate simultaneously for any given fault. In cases where sufficient CTs are not available for ...
MS-5012 - Fire
MS-5012 - Fire

... A fire alarm system will not operate without any electrical power. If AC power fails, the system will operate from standby batteries only for a specified time and only if the batteries have been properly maintained and replaced regularly. Equipment used in the system may not be technically compatibl ...
NRC INSPECTION MANUAL
NRC INSPECTION MANUAL

... requiring correction. When significant inadequacies are identified indicating weakness within the responsible organization, the inspector should inform ...
Grounding and Bonding
Grounding and Bonding

UMC100-FBP Marketing Presentation
UMC100-FBP Marketing Presentation

1977 - HP Archive
1977 - HP Archive

... OPEN SIGNAL PATH - The pulserl probe combination shows a bad level (dim lamp) at an output. A bad level at an output pin usually indicates an open output bond. To make sure, piggyback the IC under test with another of the same type known to be good. ...
P83862
P83862

... directed to control supervision and power delivery to any combination of the four (4) outputs. Each output is rated at 2 AMPS (either Class "A" or Class "B") and can be programmed to generate a steady or Code 3 Temporal horn sound and a strobe output under alarm condition. A maximum 4 AMP output is ...
MultyMass MMC2 - badger meter europa gmbh
MultyMass MMC2 - badger meter europa gmbh

... These instructions are an important part of the product and must be kept for later use. These instructions are intended as an overview and do not contain detailed information on all designs for this product or every possible aspect of installation, operation and maintenance. For additional informati ...
EXPERIMENTAL INVESTIGATION Laboratory test # 1/1 Direct
EXPERIMENTAL INVESTIGATION Laboratory test # 1/1 Direct

Vacuum Circuit Breaker Technology
Vacuum Circuit Breaker Technology

... vapor being placed in the contact zone and thereby limiting the fault rating of the interrupter. In order to improve the interrupter’s fault capacity either the spiral or axial magnetic field (AMF) contact design can be applied. These contacts are used in higher fault ratings as they are able to uti ...
Investigation Of Factors Affecting The Sustainability Of Arcs
Investigation Of Factors Affecting The Sustainability Of Arcs

... For a single phase a-c arc the current flow between two electrodes will go to zero at the end of each half cycle and deionization begins. The race between deionization and recovery voltage determines if the arc re-ignites. In a three phase arcing event, current flow through an arc will always be pre ...
2N4391 - Linear Systems
2N4391 - Linear Systems

... Information furnished by Linear Integrated Systems is believed to be accurate and reliable. However, no responsibility is assumed for its use; nor for any infringement of patents or other rights of third parties which may result from its use. No license is granted by implication or otherwise under a ...
Factory Acceptance Test (FAT) of protection relays  Jim Sandbacka
Factory Acceptance Test (FAT) of protection relays Jim Sandbacka

... 2.1 Synchronous generators and their attributes Synchronous generators are electrical machines, but instead of consuming power from the network an auxiliary power source, such as turbines or engines, is rotating the generator’s rotor and when synchronous speed is achieved it is possible to connect t ...
Defense - Auburn University
Defense - Auburn University

... Level converters are of two types  Feedback based level converter  Differential cascaded voltage switched (standard level converter)  Pass transistor level converter.  Contention mitigated level converter  Multi-Vth based level converter  Dual Vth cascaded inverter level converter.  Multi- Vt ...
BDTIC
BDTIC

... Electrostatic discharge (ESD) plays an important role when ESD sensitive devices are connected to exposed interfaces or antennas that can be touched by humans. This is usually applicable to low noise amplifiers (LNAs) and therefore LNAs must be properly protected against ESD in order to avoid irreve ...
Automatic Transfer Switch Protection
Automatic Transfer Switch Protection

... Additional electrical room floor space required = 20 in. x 160 in. This is a very common situation. It may or may not be made clear during a bid or submittal review that these changes have occurred, but the added costs are real. These additional costs are in most cases figured in by the ATS manufact ...
day9
day9

... What do we do about it? • Tolerate faulty components • Detect faults – Not do anything bad – Try it again • If statistically unlikely error, –high likelihood won’t recur. ...
User manual
User manual

... The digital servo amplifier JetMove 208-480 may only be operated in the closed control cabinet and within the range of the set values. Do not apply a voltage to the digital servo amplifier JetMove 208-480 that is higher than the prescribed operating voltage. Each of the three phases of the digital s ...
MAX4370 Current-Regulating Hot-Swap Controller with DualSpeed/BiLevel Fault Protection General Description
MAX4370 Current-Regulating Hot-Swap Controller with DualSpeed/BiLevel Fault Protection General Description

... current limiting is provided two different ways: 1) Slow ramping of the current to the load by controlling the external MOSFET gate voltage. 2) Limiting the current to the load by regulating the voltage across the external current-sense resistor. Unlike other circuit-breaker ICs, the MAX4370 hot-swa ...
CLiP® APPLICATION TYPICAL QUESTIONS AND ANSWERS
CLiP® APPLICATION TYPICAL QUESTIONS AND ANSWERS

... No, the CLiP does not vent or issue a flame during interruption. It is not an expulsion device. It does allow a very gradual pressure relief through the stranding of its triggering wire so that personnel replacing the interrupter are not working with a highly pressurized device. 5. Can the CLiP be u ...
inverter 002 guide
inverter 002 guide

... provide the in-service or install date on the warranty claim form will cause the warranty period to begin on the date the part was manufactured or date of sale recorded on the original sales invoice, whichever is earlier. A completed warranty claim form should accompany all parts submitted to Purkey ...
< 1 ... 22 23 24 25 26 27 28 29 30 ... 256 >

Fault tolerance



Fault tolerance is the property that enables a system to continue operating properly in the event of the failure of (or one or more faults within) some of its components. If its operating quality decreases at all, the decrease is proportional to the severity of the failure, as compared to a naively designed system in which even a small failure can cause total breakdown. Fault tolerance is particularly sought after in high-availability or life-critical systems.A fault-tolerant design enables a system to continue its intended operation, possibly at a reduced level, rather than failing completely, when some part of the system fails. The term is most commonly used to describe computer systems designed to continue more or less fully operational with, perhaps, a reduction in throughput or an increase in response time in the event of some partial failure. That is, the system as a whole is not stopped due to problems either in the hardware or the software. An example in another field is a motor vehicle designed so it will continue to be drivable if one of the tires is punctured. A structure is able to retain its integrity in the presence of damage due to causes such as fatigue, corrosion, manufacturing flaws, or impact.Within the scope of an individual system, fault tolerance can be achieved by anticipating exceptional conditions and building the system to cope with them, and, in general, aiming for self-stabilization so that the system converges towards an error-free state. However, if the consequences of a system failure are catastrophic, or the cost of making it sufficiently reliable is very high, a better solution may be to use some form of duplication. In any case, if the consequence of a system failure is so catastrophic, the system must be able to use reversion to fall back to a safe mode. This is similar to roll-back recovery but can be a human action if humans are present in the loop.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report